Myson 1370064 manual OperationDisplay, Manual, Troubleshooting, Locking Unit Controls

Page 10

10SLIM-LINE RC

11.0Operating Instructions (continued...)

OperationDisplay

Power off

No Display

Switch on supply to unit

for 30 seconds

(unit off)

 

 

Supply on / unit off

Manual

Manual mode can be used for air circulation without heat or for manual control of the heating function.

Use ‘+’ to scroll

Selected fan speed

beyond 35°C

displayed

Or use ‘-’ to scroll

 

below 15°C

 

Switch on unit

Set point flashes for

 

approx 5 secs, then

Ambient temperature displayed

Scrolling back out of manual using the ‘+’ or ‘–’ button will revert the unit back to last temperature set point.

Use ‘+/-’ to adjust

 

 

 

 

 

Set point flashes for

set point

 

 

 

 

 

approx 5 secs, then

 

 

 

 

 

 

 

 

Ambient temperature

The ambient temperature is always displayed unless the water temperature falls below 43°C*, or if the set point is being adjusted.

Water temp <43°C

Shows both power

 

& unit on

*43°C in normal heating system, 32°C for heat pumps and above 20°C in cooling.

12.0 Troubleshooting

Locking Unit Controls

The control panel on the main unit can be locked electronically to prevent interference once the controls have been set. After setting the unit to the desired temperature setting and with the unit in running mode, press the On/Off button on the main unit for about 6 seconds until the two middle horizontal bars appear on the display. The horizontal bars will disappear after about 6 seconds and the unit is in key lock mode.

If any of the unit controls are pressed the horizontal bars will reappear to show the key lock mode is activated, however, during this mode the handset controls remain functional.

To unlock the system press the On/Off button for about 6 seconds until the horizontal bars disappear.

Once installed this fan convector becomes part of a complete heating system that will generally include a boiler, pump, other emitters such as radiators and fan convectors, and a number of heating controls, dependent on system complexity. An apparent problem with this unit may be the result of system controls being incorrectly set and can be solved easily without calling out your installer or MYSON Service. Before calling your installer or MYSON Service, please carry out the checks listed opposite.

Note: If you call out MYSON Service to a fault detailed opposite, or to repair a fault caused by incorrect use, a call out charge will be made.

Image 10
Contents Heatingthroughinnovation Please leave this manual with the end userContents 10.0 11.0 12.0 13.0Unit Selection/Sizing General InformationLocation Preparation Fixing150 Water ConnectionsElectrical Connection Adjustment Heating Mode Commissioning ProcedureDisplayed Temperature Calibration Switch Switch Down Switch UpApproximate Hydraulic Resistance through Fan Convectors Technical Data Heating Performance DataNoise levels in accordance with EN Controls Display Operating InstructionsDescription HeatingManual TroubleshootingOperationDisplay Locking Unit ControlsProblem Possible Causes Problem Possible Causes RemedyCommon Installation Faults 11.0 MaintenanceAfter Sales Service