Multiquip QP-301TH manual Rules for Safe Operation

Page 9

NEVER Run engine without air cleaner. Severe engine damage may occur.

ALWAYS read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using pump.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

NEVER leave the pump unattended, turn off engine when unattended.

Unauthorized equipment modifications will void all warranties.

NEVER pump volatile, explosive, flammable or low flash point fluids.These fluids could ignite or explode.

NEVER operate the pump in an explosive atmosphere.

Before starting the pump, check that the clean-out cover is securely fasten.

ALWAYS ensure pump is on level ground before use.

Become familiar with the components of the pump before operating.

ALWAYS replace any worn or damaged warning decals.

NEVER pump corrosive chemicals or water containing toxic substances. These fluids could create serious health and environmental hazards. Contact local authorities for assistance.

NEVER open the priming plug when pump is hot. Hot water inside could be pressurized much like the radiator of an automobile. Allow pump to cool to the touch before loosening plug.

NEVER open the pump housing during operation or start the pump with the clean-out cover removed.The rotating impeller inside the pump can cut or sever objects caught in it.

NEVER block or restrict flow from discharge hose. Remove kinks from discharge line before starting pump. Operation with a blocked discharge line can cause water inside pump to overheat.

ALWAYS fill the pump casing with water before starting the engine. Failure to maintain water inside the pump housing will cause severe damage to the pump.

In winter drain water from pump housing to prevent freezing.

RULES FOR SAFE OPERATION

High Temperatures – Always stop engine and allow the engine to cool before adding fuel, oil or performing service and maintenance functions. Contact with hot components can cause serious burns.

NEVER disconnect any "emergency or safety devices". These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death! Disconnection of any of these devices will void all warranties.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

ALWAYS allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts, or missing decals.

Dispose of hazardous waste properly.Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

Emergencies

ALWAYS know the location of the nearest fire extinguisher.

ALWAYS know the location of the nearest first aid kit.

In emergencies always know the location of the nearest phone or keep a phone on the job site. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

QP-301TH TRASH PUMP — PARTS MANUAL— REV. 4 (10/05/05 ) — PAGE 9

Image 9
Contents Multiquip Model QP-301TH Gasoline Powered Trash Pump 2 QP-301TH Trash Pump Parts Manual REV. #4 10/05/05 Heres HOW to GET Help QP-301TH Table of Contents When ordering parts Please supply the following information Parts Ordering Procedures QP-202TH Safety Message Alert Symbols Accidental Starting Rules for Safe Operation General SafetyRules for Safe Operation Specifications Pump Specifications Engine Application QP-301TH General InformationQP-301TH Pump Components Initial Servicing QP-301TH Basic EngineQP-301TH PRE-INSPECTION Engine Read safety instructions at the beginning of manual QP-301TH PRE-SETUP PumpQP-301TH Initial START-UP Engine QP-301TH Initial START-UP Engine QP-301TH Trash Pump Parts MANUAL- REV 10/05/05 Pump Vacuum Test QP-301TH Maintenance PumpQP-301TH Maintenance Pump Engine Maintenance Schedule QP-301TH Maintenance EngineQP-301TH Maintenance Engine Pump Storage QP-301TH Preparation for Long -TERM StorageQP-301TH Trash Pump Parts MANUAL- REV 10/05/05 Engine Troubleshooting QP-301TH Troubleshooting EngineQP-301TH Troubleshooting ENGINE/PUMP Items Found In the Items Number Column QP-301TH Explanation of Code in Remarks ColumnQP-301THTRASH PUMP1TO 3 Units Honda GX240K1PA2 Engine QP-301TH Suggested Spare PartsPump Assy QP-301TH Pump AssyCasing NPS3 ENGINE, HondaCasing Cover Suction Cover NPS332 QP-301TH Trash Pump Parts Manual REV. #4 10/05/05 Bolt Casing Cover M8 X Bolt Engine M10 XWasher M10 Seal Washer M8AIR Cleaner Assy Honda GX240K1PA2 Engine AIR Cleaner AssyGROMMET, AIR Cleaner COVER, AIR CleanerCOLLAR, AIR Cleaner Collar B, AIR CleanerCamshaft Assy Honda GX240K1PA2 Engine Camshaft AssyARM, Valve Rocker SPRING, Weight ReturnLIFTER, Valve PIVOT, Rocker ARMCarburetor Assy Honda GX240K1PA2 Engine Carburetor AssyEngine S/N BE70B a Gasket SET Valve SET, Float Float SETScrew SET, Drain Screw SET B Choke SET Includes Items W SCREW, Throttle Stop NOZZLE, Main Collar SETControl Assy Honda GX240K1PA2 Engine Control AssyARM, Governor SPRING, Control AdjustingROD, Governor SPRING, GovernorCrankcase Cover Assy Honda GX240K1PA2 Engine Crankcase Cover AssyHOLDER, Governor Weight WEIGHT, GovernorPIN, Governor Weight GASKET, Case CoverHonda GX240K1PA2 Engine CRANKSHAFT/BALANCER Assy Crankshaft /BALANCER Weight AssyHonda GX240K1PA2 Engine CRANKSHAFT/BALANCER Assy WEIGHT, BalancerCylinder Barrel Assy Honda GX240K1PA2 Engine Cylinder Barrel AssyBOLT, Drain PLUG2 SHAFT, Governor ARMWasher NUT, Flange 10MMCylinder Head Assy Honda GX240K1PA2 Engine Cylinder Head AssyCLIP, Valve Guide GUIDE, Valve OS OptionalGASKET, Cylinder Head COVER, HeadFAN Cover Assy Honda GX240K1PA2 Engine FAN Cover AssyCLIP, Tube CLIP, Wire HarnessShroud SUB- HarnessFlywheel Assy Honda GX240K1PA2 Engine Flywheel AssyFlywheel FAN, CoolingFuel Tank Assy Honda GX240K1PA2 Engine Fueltank AssyJOINT, Fuel Tank RUBBER, Supporter 107MMTANK, Fuel *NH1* Black GASKET, Fuel Filler CAPIgnition Coil Assy Honda GX240K1PA2 Engine Ignition Coil AssyCoil ASSEMBLY, Ignition GROMMET, WireWIRE, Stop Switch 370MM Muffler Assy Honda GX240K1PA2 Engine Muffler AssyPROTECTOR, Muffler MufflerPROTECTOR, Exhaust Pipe PIPE, ExhaustPiston Assy Honda GX240K1PA2 Engine Piston AssyRing SET, Piston Standard BOLT, Connecting RODRing SET, Piston OS0.25 Ring SET, Piston OS.50Recoil Starter Assy Honda GX240K1PA2 Engine Recoil Starter AssyRACHET, Starter PULLEY, Recoil StarterSPRING, Friction SPRING, Starter Return64 QP-301TH Trash Pump Parts Manual REV. #4 10/05/05 Honda GX240K1PA2 Engine Gasket KIT Assy Gasket KIT AssyGASKET, CYL. Head Cover Abels Assy Honda GX240K1PA2 Engine Labels AssyMARK, Caution External Emblem InternalLABEL, Caution MARK, Choke ExternalEffective October 1, 2002 Terms and Conditions of Sale Parts QP-301TH Trash Pump Parts MANUAL- REV 10/05/05 Multiquip INC