Multiquip GB12BS, GB12BW, GB12BP manual LIgHTINg sYsTeM saFeTY, LaMp saFeTY, TraNsporTINg saFeTY

Page 8

Safety Information

LIgHTINg sYsTeM saFeTY

warNINg

Never disconnect any emergency or safety devices.

These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.

CauTIoN

Never attempt service on a running machine.

NOTICE

To prevent the lighting system from overturning, Never use in winds that exceed 22 mph (10 m/s).

The lighting system should only be used in temperatures between 23° to 104°F (-5° to 40° C). Failure to comply with these operating parameters could cause the lamp to malfunction and shorten the ballast life.

ALWAYS keep the lighting system in proper running condition.

Fix damage to lighting system and replace any broken parts immediately.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel.

LaMp saFeTY

warNINg

Never attempt to replace lamp with the power on. Always unplug the power cord from the generator or power source when changing the lamp.

ALWAYS allow a sufficient amount of time for the lamp to cool before changing.The possibility exists of severe burns.

CauTIoN

Never use force when installing the lamp.Excessive force could cause the lamp to break, causing bodily harm.

NOTICE

Never leave any grease or oil residue on lamp surface when replacing or removing lamp. This can create hot spots, reducing the service life of the lamp.

ALWAYS make sure lamp surface is clean and dry.

ALWAYS replace with MQ recommended type lamp. See parts section of this manual.

If applicable, ALWAYS make sure the lamp guard is installed correctly. Never deform the lamp guard.

Never unplug the lamp’s AC power cable during operation.

ALWAYS have a trained technician to install and remove lamp or replace any damaged fi xture wiring.

TraNsporTINg saFeTY

NOTICE

When transporting the tripod lighting system, if applicable, always place in stow position and place tripod in its carrying case.

ALWAYS remove balloon/lamp assembly from the mast when transporting lighting system. This will prevent damage to the bulb due to vibration.

Never leave the balloon/lamp exposed during transport. Exposure to excess wind or rain could damage the balloon’s nylon cover.

ALWAYS place balloon inside its protective cover during transport. Be sure the cover is secured tightly around the balloon/lamp assembly.

page 8 —gb12bw/bs/bp LIGHTING SYSTEM • operation and parts manual — rev. #0 (06/24/13)

Image 8
Contents Models GB12BW Page Page Table of Contents GB12BW/BS/BP Lighting SystemChoose from three easy options SaFeTY sYMboLs Safety informationSaFeTY Messages GeNeraL saFeTY TraNsporTINg saFeTY LIgHTINg sYsTeM saFeTYLaMp saFeTY BaLLooN saFeTY MasT saFeTYELeCTrICaL saFeTY Power Cord/Cable safetySpecifications SpecificationsDimensions GB12BW DimensionsDimensions GB12BS Dimensions GB12BSDimensions GB12Bp Dimensions GB12BPFootcandle plot Values listed as footcandlesGeneral information Components Major ComponentsComponents Setup gb12bw Tripod Deployment GB12BWBalloon Assembly Placement GB12BW Place balloon assembly onto mast and tighten Upper T-handleRaising the Mast GB12BW Sand BagsApplying Power GB12BW Operation gb12bwStorage Lowering the MastPlace tripod inside protective carrying case Setup gb12bS Pole Setup GB12BSRemovingthe Protective Covering GB12BS Attachment of S-HooksRaising the Mast GB12BS Applying Power GB12BSOperation gb12bS Maintenance Replacing the LampInstalling Lamp Replacing Balloon EnvelopeFilter replacement Accessing FilterGB12BW GB12BP Periodic Check and Maintenance Wiring Diagram Troubleshooting Lamp TroubleshootingExplanation of code in remarks column Suggested spare parts GloBug Lighting System 1 to 3 UnitsNameplate and decals gb12bw Part Name Nameplate and decals gb12bs Part Name QTY. Remarks Nameplate and decals gb12bp Nameplate and decals gb12bp Mast/tripod assy Tripod Cover Fan blower/lamp assy ELE-BALLAST Assy Balloon/lamp guard assy LAMP, MP400 Offset pole assy. gb12BS Remarks Terms and Conditions of Sale Parts FreIgHT poLICYPage HERE’S HOW to GET Help
Related manuals
Manual 52 pages 60.03 Kb

GB12BS, GB12BP, GB12BW specifications

The Multiquip GB12 series of concrete trowels, including the GB12BW, GB12BP, and GB12BS models, represents a significant advancement in concrete finishing technology. These trowels are engineered to deliver optimal performance and efficiency on job sites, making them indispensable for contractors and professionals in the field.

One of the standout features of the GB12 series is its robust and durable design. Constructed with high-quality materials, these trowels are built to withstand the rigors of heavy use while maintaining precision and reliability. The GB12BW model is particularly notable for its weight distribution, which allows for a smooth finish on larger surfaces. Its blade size is engineered to cover expansive areas rapidly, making it an excellent choice for large projects.

The GB12BP variant caters to those seeking a powered trowel that can deliver enhanced performance with less manual effort. It is equipped with a powerful engine that offers substantial torque, allowing for efficient concrete finishing, even in challenging conditions. This model emphasizes user comfort and control, featuring an ergonomic handle system that reduces operator fatigue during extended use.

For those who prioritize safety, the GB12BS model includes advanced safety features designed to mitigate risks on job sites. Safety guards and emergency stop controls are integrated into the design, ensuring that operators can quickly halt operations if necessary. These features are crucial for maintaining a secure working environment, especially when operating heavy machinery like trowels.

The trowels in the GB12 series offer versatility in finishing options. Equipped with interchangeable blade types, users can select different blade configurations to achieve varied surface textures, from a smooth finish to a rougher surface. Additionally, the adjustable pitch control allows operators to fine-tune the angle of the blades, accommodating different finishing styles and concrete types.

Moreover, these trowels are designed with ease of maintenance in mind. Quick-release features enable operators to swap out blades and perform routine maintenance without extensive downtime. This focus on user-friendly design ensures that the Multiquip GB12 series remains a preferred choice among professionals who demand efficiency and reliability in their equipment.

In conclusion, the Multiquip GB12BW, GB12BP, and GB12BS trowels offer a sophisticated blend of performance, safety, and versatility. Their durable construction, innovative technologies, and thoughtful design make them ideal for concrete finishing tasks of any scale, cementing their status as top-tier equipment in the construction industry.