Multiquip manual GB12BW/BS/BP Lighting System Components, Major Components

Page 14

GB12BW/BS/BP LIGHTING SYSTEM — COMPONENTS

4

3

12

GB12BW

COVER

CARRYING

CASE

GB12BP

9

10

11

2

1

8

5

6

16

7

GB12BS

13

15

14

Figure 7. Major Components

PAGE 14 — GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08)

Image 14
Contents Models GB12BW/BS/BP Table of Contents Effective January 1st GB12BW/BS/BP Lighting System -SAFETYMESSAGEALERTSYMBOLS For Your Safety and the Safety of OthersWhen raising or lowering the mast, keep General SafetyMast Safety GB12BW/BS/BP Lighting System Rules for Safe OperationLamp Safety and Care Balloon Safety and CareEven Death GB12BW/BS/BP Lighting System Specifications GB12BW/BS/BP Lighting System Dimensions GB12BW DimensionsGB12BW/BS/BP Lighting System Dimensions GB12BS Dimensions GB12BSGB12BW/BS/BP Lighting System Dimensions GB12BP DimensionsGB12BW/BS/BP Lighting System Footcandle Plot Degree coverageGB12BW/BS/BP Lighting System General Information GB12BPGB12BW/BS/BP Lighting System Components Major ComponentsGB12BW/BS/BP Lighting System Components Globug GB12BW/BS/BP Lighting System Setup GB12BW Tripod Deployment GB12BWPlace balloon assembly onto mast and tighten UpperT-handle Globug GB12BW/BS/BP Lighting System Setup GB12BWBalloon Assembly Placement GB12BW Connect the AC power cable to the lamp power cableRaising the Mast GB12BW Always make sureGlobug GB12BW/BS/BP Lighting System Operation GB12BW Applying Power GB12BWDisconnect lamp power connector from the AC power cable StorageGlobug GB12BW/BS/BP Lighting System Storage GB12BW Place tripod inside protective carrying caseRefer to for the following procedure Globug GB12BW/BS/BP Lighting System Setup GB12BSPole Setup GB12BS Removing the Protective Covering GB12BS Globug GB12BW/BS/BP Lighting System Setup GB12BSConnecting Power Cable GB12BS GB12BS lighting system is now ready for use Applying Power GB12BSRaising the Mast GB12BS Remove lamp guard Figure Globug GB12BW/BS/BP Lighting System MaintenanceRelease the lamp guard locking tabs Figure Globug Solo Jr. Lighting System Maintenance GB12BW/BS/BP Lighting System Maintenance Filter ReplacementGB12BW/BS/BP Lighting System -MAINTENANCEWIRINGDIAGRAM LW1GB12BP GB12BW E1 GB12BS GB12BW/BS/BP Lighting System Maintenance Periodic Check and MaintenanceGB12BW/BS/BP Lighting System -TROUBLESHOOTING Lamps Symptom Possible Problem SolutionGB12BW/BS/BP Lighting System -TROUBLESHOOTING Mast Mast TroubleshootingSpecification and part Explanation of Code in Remarks ColumnGB12BW/BS/BP Lighting System Spare Parts Qty DescriptionGB12BW/BS/BP Lighting System Nameplate and Decals InformationPart Name GB12BW/BS/BP Lighting System MAST/TRIPOD ASSY. GB12BW GB12BW/BS/BP Lighting System Mast /TRIPODASSY. GB12BW RemarksGB12BW/BS/BP Lighting System FAN BLOWER/LAMP Base Assy 0043210000 22145001302214500230 0043110000GB12BW/BS/BP Lighting System BALLOON/LAMP Guard Assy Part Name QTY Remarks GB12BW/BS/BP Lighting System Offset Pole ASSY. GB12BS Offset Pole Terms and Conditions of Sale Parts Page Heres HOW to GET Help

GB12BW/BS/BP specifications

The Multiquip GB12BW/BS/BP is a versatile and powerful generator designed to meet diverse energy needs in various applications, from construction sites to outdoor events. Recognized for its reliability and efficiency, this generator series is popular among professionals and contractors seeking a robust power solution.

Key features of the GB12 series include its impressive output capabilities. The GB12BW, for instance, offers a continuous operation of 12 kW, making it suitable for powering multiple tools and equipment simultaneously. The machine operates with a three-phase or single-phase output, which adds versatility, catering to both larger power demands and smaller, localized needs.

One of the standout technologies within the GB12 lineup is its advanced noise reduction system. The generators are equipped with soundproof enclosures designed to minimize operational noise without sacrificing performance. This feature is particularly beneficial in noise-sensitive environments such as residential areas or during nighttime operations.

In terms of fuel efficiency, the GB12BW/BS/BP models are engineered with high-performance engines that ensure maximum runtime on a single tank of fuel. This efficiency is crucial for prolonged job sites where refueling may be inconvenient. Additionally, with lower fuel consumption rates, operators can reduce operational costs while maintaining productivity.

Durability is another hallmark of the GB12 series. Constructed with high-quality materials, these generators are built to withstand the rigors of heavy-duty use. The compact design allows for easy transportation, while the robust frame ensures stability during operation. This makes the GB12 ideal for both stationary and mobile applications.

User-friendly controls and features such as automatic voltage regulation make the GB12 series easy to operate. This technology ensures a steady power supply and protects connected equipment from voltage fluctuations, enhancing safety and equipment longevity.

Furthermore, the GB12 models come equipped with comprehensive safety features, including low oil shutdown and circuit breakers, which prevent damage and reduce the risk of accidents during operation.

In summary, the Multiquip GB12BW/BS/BP series offers a reliable, efficient, and durable power solution for various applications. With advanced technologies, enhanced fuel efficiency, and user-friendly features, it meets the demands of modern professionals seeking maximum productivity in their power generation needs.