Multiquip GB12BW/BS/BP manual Lamp Safety and Care, Balloon Safety and Care

Page 6

GB12BW/BS/BP LIGHTING SYSTEM — RULES FOR SAFE OPERATION

When transporting the tripod lighting system, always place tripod in the stow position, then place tripod into its carrying case.

ALWAYS remove the balloon/lamp assembly from the mast when transporting any of the GloBug lighting systems. This will prevent damage to the bulb due to vibration.

NEVER leave the balloon/lamp exposed during transport. Exposure to excess wind or rain could damage the balloon's nylon cover.

ALWAYS place the balloon inside its protective cover during transport. Be sure the cover is secured tightly around the balloon/lamp assembly.

LAMP SAFETY AND CARE

NEVER leave any grease or oil residue on lamp surface when replacing or removing lamp. This can create hot spots, reducing the service life of the lamp.

ALWAYS make sure the lamp surface is clean and dry.

ALWAYS replace with MQ recommended type lamp. See parts section of this manual.

NEVER use force when installing the lamp. Excessive force could cause the lamp to break causing bodily harm.

ALWAYS make sure the lamp guard is installed correctly. NEVER deform the lamp guard.

NEVER attempt to replace lamp with the power on. Always unplug the power cord from the generator or power source when changing the lamp.

NEVER unplug the lamp's AC power cable during operation.

ALWAYS allow a sufficient amount of time for the lamp to cool before changing. The possibility exists of severe burns.

ALWAYS have a trained technician to install and remove lamp, or replace any damaged fixture wiring.

BALLOON SAFETY AND CARE

To prevent serious burns, NEVER touch or unzip the balloon envelope when the lamp is on.

To prevent the balloon from deformation, NEVER use any GloBug lighting system in strong winds.

DO NOT place the balloon inside its protective cover until the lamp has had a sufficient amount of time to cool down. This will prevent the balloon's nylon cover from being burned (touching the lamp surface).

ALWAYS place the balloon inside its protective cover after each use. This will prolong the life of the balloon material, keeping it protected from harsh environmental elements.

DO NOT use a damaged balloon. Replace balloon immediately if damaged. In addition, a damaged balloon will not inflate properly, and may become more damaged by touching the hot lamp surface.

ALWAYS keep the balloon away from sharp objects and excessive amounts of heat (fire!).

DO NOT use excessive force when zipping and unzipping the balloon. Be gentle with the zipper mechanism. If the zipper is broken the balloon will become unusable.

DANGER - Grounding

All GloBug lighting systems are equipped with a ground pin on the power plug. For your protection. ALWAYS complete the grounding path. NEVER insert the AC power plug

into a 2-prong receptacle to operate any GloBug lighting system.

When applying power to the lighting system, always connect the AC power plug to a 3-prong receptacle that is grounded.The possibility exists of Electrical Shock, Electrocution, and even Death if the lighting system is not grounded.

PAGE 6 — GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08)

Image 6
Contents Models GB12BW/BS/BP Table of Contents Effective January 1st GB12BW/BS/BP Lighting System -SAFETYMESSAGEALERTSYMBOLS For Your Safety and the Safety of OthersWhen raising or lowering the mast, keep General SafetyMast Safety GB12BW/BS/BP Lighting System Rules for Safe OperationLamp Safety and Care Balloon Safety and CareEven Death GB12BW/BS/BP Lighting System Specifications GB12BW/BS/BP Lighting System Dimensions GB12BW DimensionsGB12BW/BS/BP Lighting System Dimensions GB12BS Dimensions GB12BSGB12BW/BS/BP Lighting System Dimensions GB12BP DimensionsGB12BW/BS/BP Lighting System Footcandle Plot Degree coverageGB12BW/BS/BP Lighting System General Information GB12BPGB12BW/BS/BP Lighting System Components Major ComponentsGB12BW/BS/BP Lighting System Components Globug GB12BW/BS/BP Lighting System Setup GB12BW Tripod Deployment GB12BWPlace balloon assembly onto mast and tighten UpperT-handle Globug GB12BW/BS/BP Lighting System Setup GB12BWBalloon Assembly Placement GB12BW Connect the AC power cable to the lamp power cableRaising the Mast GB12BW Always make sureGlobug GB12BW/BS/BP Lighting System Operation GB12BW Applying Power GB12BWDisconnect lamp power connector from the AC power cable StorageGlobug GB12BW/BS/BP Lighting System Storage GB12BW Place tripod inside protective carrying caseGlobug GB12BW/BS/BP Lighting System Setup GB12BS Pole Setup GB12BSRefer to for the following procedure Globug GB12BW/BS/BP Lighting System Setup GB12BS Connecting Power Cable GB12BSRemoving the Protective Covering GB12BS Applying Power GB12BS Raising the Mast GB12BSGB12BS lighting system is now ready for use Globug GB12BW/BS/BP Lighting System Maintenance Release the lamp guard locking tabs FigureRemove lamp guard Figure Globug Solo Jr. Lighting System Maintenance GB12BW/BS/BP Lighting System Maintenance Filter ReplacementGB12BW/BS/BP Lighting System -MAINTENANCEWIRINGDIAGRAM LW1GB12BP GB12BW E1 GB12BS GB12BW/BS/BP Lighting System Maintenance Periodic Check and MaintenanceGB12BW/BS/BP Lighting System -TROUBLESHOOTING Lamps Symptom Possible Problem SolutionGB12BW/BS/BP Lighting System -TROUBLESHOOTING Mast Mast TroubleshootingSpecification and part Explanation of Code in Remarks ColumnGB12BW/BS/BP Lighting System Spare Parts Qty DescriptionGB12BW/BS/BP Lighting System Nameplate and Decals InformationPart Name GB12BW/BS/BP Lighting System MAST/TRIPOD ASSY. GB12BW GB12BW/BS/BP Lighting System Mast /TRIPODASSY. GB12BW RemarksGB12BW/BS/BP Lighting System FAN BLOWER/LAMP Base Assy 0043210000 22145001302214500230 0043110000GB12BW/BS/BP Lighting System BALLOON/LAMP Guard Assy Part Name QTY Remarks GB12BW/BS/BP Lighting System Offset Pole ASSY. GB12BS Offset Pole Terms and Conditions of Sale Parts Page Heres HOW to GET Help

GB12BW/BS/BP specifications

The Multiquip GB12BW/BS/BP is a versatile and powerful generator designed to meet diverse energy needs in various applications, from construction sites to outdoor events. Recognized for its reliability and efficiency, this generator series is popular among professionals and contractors seeking a robust power solution.

Key features of the GB12 series include its impressive output capabilities. The GB12BW, for instance, offers a continuous operation of 12 kW, making it suitable for powering multiple tools and equipment simultaneously. The machine operates with a three-phase or single-phase output, which adds versatility, catering to both larger power demands and smaller, localized needs.

One of the standout technologies within the GB12 lineup is its advanced noise reduction system. The generators are equipped with soundproof enclosures designed to minimize operational noise without sacrificing performance. This feature is particularly beneficial in noise-sensitive environments such as residential areas or during nighttime operations.

In terms of fuel efficiency, the GB12BW/BS/BP models are engineered with high-performance engines that ensure maximum runtime on a single tank of fuel. This efficiency is crucial for prolonged job sites where refueling may be inconvenient. Additionally, with lower fuel consumption rates, operators can reduce operational costs while maintaining productivity.

Durability is another hallmark of the GB12 series. Constructed with high-quality materials, these generators are built to withstand the rigors of heavy-duty use. The compact design allows for easy transportation, while the robust frame ensures stability during operation. This makes the GB12 ideal for both stationary and mobile applications.

User-friendly controls and features such as automatic voltage regulation make the GB12 series easy to operate. This technology ensures a steady power supply and protects connected equipment from voltage fluctuations, enhancing safety and equipment longevity.

Furthermore, the GB12 models come equipped with comprehensive safety features, including low oil shutdown and circuit breakers, which prevent damage and reduce the risk of accidents during operation.

In summary, the Multiquip GB12BW/BS/BP series offers a reliable, efficient, and durable power solution for various applications. With advanced technologies, enhanced fuel efficiency, and user-friendly features, it meets the demands of modern professionals seeking maximum productivity in their power generation needs.