GA-6RE/GA-6REA — INITIAL START-UP (ENGINE)

CAUTION

DO NOT attempt to operate this generator until the Safety, General Information and Inspection sections of this manual have been read and thoroughly understood.

This section is intended to assist the operator with the initial start-upof the portable generator. It is extremely important that this section be read carefully before attempting to use the generator in the field.

Before Starting the Engine

1.Be sure to disconnect all electrical loads from the Generators prior to starting the engine.

2.NEVER start the engine with the main circuit breaker in the “ON" position. Always place this circuit breaker (Figure 10) in the OFF position before starting.

Figure 10. Main Circuit Breaker (OFF Position)

Starting the Engine

1.Place the engine fuel valve lever (Figure 11) in the "ON" position.

Figure 11. Engine Fuel Valve Lever (ON Position)

2.Placethechokelever (Figure12)inthe"CLOSED"position if starting a cold engine.

Figure 12. Choke Lever

3.Place the choke lever (Figure 12) in the "OPEN " position if starting a warm engine or the temperature is warm.

4.Place the generator's operation switch (Figure 13) in the "ON" position.

Figure 13. Operation Switch (ON Position)

5.Press the Generators start switch (Figure 14) and listen for the engine to start. If the battery is not installed proceed to step 6.

Figure 14. Start Pushbutton Switch

6.Grasp the startergrip (Figure 15) and slowly pull it out.The resistancebecomesthehardestatacertainposition,corre- sponding to the compression point. Pull the starter grip briskly and smoothly for starting.

Figure 15. Starter Grip

CAUTION

DO NOT pull the starter rope all the way to the end.

DO NOT release the starter rope after pulling. Allow it to rewind as soon as possible.

GA-6RE/GA-6REA A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (06/06/05) — PAGE 25

Image 25
Contents Model GA-6RE/GA-6REA Page Heres HOW to GET Help Table of Contents When ordering parts Please supply the following information Parts Ordering ProceduresBurn Hazards GA-6RE/GA-6REA Safety Message Alert SymbolsRespiratory Hazards Equipment Damage GA-6RE/GA-6REA Safety Message Alert SymbolsRotating Parts Hazards Read this manual GA-6RE/GA-6REA Rules for Safe OperationGA-6RE/GA-6REA Rules for Safe Operation Power Cord SafetyEmergencies DeathMachine Safety Decals GA-6RE/GA-6REA Operation and Safety DecalsEffects of Altitude and Heat GA-6RE/GA-6REA Specifications GeneratorGA-6RE/GA-6REA Specifications Engine Specifications EngineDimensions GA-6RE/GA-6REA DimensionsGA-6RE/GA-6REA General Information Extension Cables Single Phase Load 60 HzGenerator Components GA-6RE/GA-6REA Controls and IndicatorsV Full Power Switch Simplified Diagram Up Position GA-6RE/GA-6REA Controls and IndicatorsFuelTank Fuel tank capacity is 5 gallons 19 liters GA-6RE/GA-6REA Controls and IndicatorsGenerator Refueling GA-6RE/GA-6REA Generator RefuelingOutdoor Installation GA-6RE/GA-6REA InstallationIndoor Installation MountingConnecting the Ground GA-6RE/GA-6REA InstallationGA-6RE/GA-6REA PRE General Inspection Prior to Operation Ground Power ToolsExtension Cable Main Circuit BreakerBefore Starting GA-6RE/GA-6REA PRE-INSPECTION EngineEngine Oil Check Fuel CheckBefore Starting the Engine GA-6RE/GA-6REA Initial START-UP EngineGA-6RE/GA-6REA Initial START-UP/GENERATOR Operation Idle Control Switch OffGA-6RE/GA-6REA Generator OPERATION/SHUTDOWN Connecting the LoadStopping the Engine Generator Storage GA-6RE/GA-6REA Preparation for Longterm StorageEngine Maintenance Schedule GA-6RE/GA-6REA Maintenance EngineSpark Plug Gap Engine Air CleanerGA-6HE Maintenance Battery GA-6RE Generator Wiring Diagram GA-6RE -WIRING Diagram GeneratorGA-6REA Generator Wiring Diagram GA-6REA -WIRING Diagram GeneratorEngine Troubleshooting GA-6RE/GA-6REA -TROUBLESHOOTING EngineWhite Generator Troubleshooting GA-6RE/GA-6REA -TROUBLESHOOTING GeneratorPage GA-6RE/GA-6REA Explanation of Code in Remarks Column How to read the marks and remarks used in this partsItems Found In the Remarks Column Items Found In the Items Number ColumnDescription GA-6RE/GA-6REA Suggested Spare PartsGA-6RE/GA-6REA Nameplate and Decals Part Name QTY Remarks GA-6RE/GA-6REA Generator Assy RECTIFIER, D3SB80 GA-6RE Control BOX Assy GA-6RE Control BOX Assy GA-6REA Control BOX Assy GA-6REA Control BOX Assy GA-6RE/GA-6REA Muffler Assy Muffler GA-6RE/GA-6REA Pipe Frame Assy GA-6RE GA-6RE/GA-6REA Battery Assy Battery Band Robin EH-360YS2420 Engine AIR Cleaner Assy Robin EH-360YS2420 Engine AIR Cleaner Assy Robin EH-360YS2420 Engine Crankcase Assy Valve Guide Robin EH-360YS2420 Engine Crankshaft and Piston Assy Crankshaft CP Robin EH-360YS2420 Engine Crankshaft and Piston AssyRobin EH-360YS2420 Engine Flywheel Assy Flywheel CP Robin EH-360YS2420 Engine Governor Assy Part Name QTY. Remarks Robin EH-360YS2420 Engine Intake and Exhaust Assy Camshaft CP Robin EH-360YS2420 Engine Cooling Starting Assy Label Trade Mark Robin EH-360YS2420 Engine Carburetor Assy Throttle Valve Robin EH-360YS2420 Engine Starter Assy Brush + Robin EH-360YS2420 Engine Solenoid Assy Solenoid AY Effective October 1, 2002 Terms and Conditions of Sale Parts Page Your Local Dealer is

GA-6RE, GA-6REA specifications

The Multiquip GA-6REA and GA-6RE are high-performance generators designed for a variety of applications, from construction sites to outdoor events. Renowned for their durability and reliability, these generators are engineered to meet the demands of professionals who require consistent power in challenging environments.

One of the standout features of the GA-6REA and GA-6RE is their robust engine performance. Equipped with a powerful Honda engine, these models deliver reliable power output, ensuring that tools and equipment run smoothly without interruptions. The generators have a fuel-efficient design, maximizing runtime and minimizing operational costs. With their impressive fuel tank capacity, users can expect extended operation time before needing to refuel.

Both models come equipped with advanced features to enhance ease of use and convenience. The digital control panel includes easy-to-read displays that provide real-time information about voltage, wattage, and runtime. This user-friendly interface allows operators to monitor performance seamlessly, making it easier to manage power consumption.

The GA-6REA specifically includes advanced noise-reduction technology, making it one of the quietest generators in its class. This feature is particularly beneficial for use in residential areas or noise-sensitive environments. The sound-dampening design ensures that it remains unobtrusive, allowing users to operate confidently without disturbing neighbors.

In terms of safety, Multiquip has designed the GA-6REA and GA-6RE with multiple protective features, including automatic low oil shutdown and overload protection. These safety mechanisms help prevent engine damage and ensure safe operation, making them ideal for both novice and experienced users.

The generators are also designed for portability, featuring a sturdy frame and ergonomic handles for easy transport. Their compact size allows for easy storage and maneuverability, whether on a construction site or during a weekend camping trip.

Durability is another critical characteristic of the GA-6REA and GA-6RE. With a rugged construction that withstands tough conditions, these generators are built to last. This reliability makes them a trusted choice for professionals in various sectors, ensuring they can perform their tasks without unexpected power failures.

In summary, the Multiquip GA-6REA and GA-6RE generators combine robust performance, advanced technology, and user-friendly features, making them an excellent choice for anyone seeking reliable power solutions for demanding situations. With their fuel efficiency, noise reduction, safety features, portability, and durability, these generators stand out as essential tools for professionals and enthusiasts alike.