Multiquip manual GA-6RE/GA-6REA Rules for Safe Operation, Power Cord Safety

Page 9

GA-6RE/GA-6REA — RULES FOR SAFE OPERATION

ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using generator.

NEVER leave the generators unattended, turn off engine when unattended.

Unauthorized equipment modifications will void all warranties.

ALWAYS ensure generators are on level ground before use.

DO NOT place hands or fingers inside generators engine compartment when engine is running.

NEVER run engine without air cleaner. Severe engine damage may occur.

NEVER change or adjust the engine speed which has been set at the factory prior to shipping.

Power Cord Safety

NEVER let power cables or cords lay in water.

NEVER stand in water while AC power from the generators are being transfer to a load.

NEVER use a defective or frayed power cable. Check the cable for cuts in the insulation.

NEVER use a extension cord that is frayed or damaged where the insulation has been cut.

ALWAYS make certain that proper power or extension cord has been selected for the job See Table 4.

Grounding Safety

ALWAYS make sure that electrical circuits are properly grounded per the National Electrical Code (NEC) and local codes before operating generator. Severe injury or death! by electrocution can result from operating an ungrounded generator.

ALWAYS make sure generators are properly grounded to a suitable earth ground (GROUND ROD). See installation in this manual.

NEVER use gas piping as an electrical ground.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

HighTemperatures – Always stop engine and allow the engine to cool before adding fuel, oil or performing service and maintenance functions. Contact with hot! components can cause serious burns.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and replace any broken parts immediately.

ALWAYS replace any worn or damaged warning decals.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and un-authorized personnel.

The electrical voltage required to operate the generators can cause severe injury or even death through physical contact with live circuits. Turn all circuit breakers OFF before performing maintenance on the generator.

Dispose of hazardous waste properly.Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

Removing the engine oil drain plug while the engine is hot will result in hot oil to gush out of the oil drain plug, therefore causing severescaldingtoanypersonsinthegeneral area of the generator.

GA-6RE/GA-6REA A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (06/06/05) — PAGE 9

Image 9
Contents Model GA-6RE/GA-6REA Page Heres HOW to GET Help Table of Contents When ordering parts Please supply the following information Parts Ordering ProceduresGA-6RE/GA-6REA Safety Message Alert Symbols Burn HazardsRespiratory Hazards GA-6RE/GA-6REA Safety Message Alert Symbols Equipment DamageRotating Parts Hazards Read this manual GA-6RE/GA-6REA Rules for Safe OperationGA-6RE/GA-6REA Rules for Safe Operation Power Cord SafetyEmergencies DeathMachine Safety Decals GA-6RE/GA-6REA Operation and Safety DecalsEffects of Altitude and Heat GA-6RE/GA-6REA Specifications GeneratorGA-6RE/GA-6REA Specifications Engine Specifications EngineDimensions GA-6RE/GA-6REA DimensionsGA-6RE/GA-6REA General Information Extension Cables Single Phase Load 60 HzGenerator Components GA-6RE/GA-6REA Controls and IndicatorsV Full Power Switch Simplified Diagram Up Position GA-6RE/GA-6REA Controls and IndicatorsFuelTank Fuel tank capacity is 5 gallons 19 liters GA-6RE/GA-6REA Controls and IndicatorsGenerator Refueling GA-6RE/GA-6REA Generator RefuelingOutdoor Installation GA-6RE/GA-6REA InstallationIndoor Installation MountingConnecting the Ground GA-6RE/GA-6REA InstallationGA-6RE/GA-6REA PRE General Inspection Prior to Operation Ground Power ToolsExtension Cable Main Circuit BreakerBefore Starting GA-6RE/GA-6REA PRE-INSPECTION EngineEngine Oil Check Fuel CheckBefore Starting the Engine GA-6RE/GA-6REA Initial START-UP EngineGA-6RE/GA-6REA Initial START-UP/GENERATOR Operation Idle Control Switch OffConnecting the Load GA-6RE/GA-6REA Generator OPERATION/SHUTDOWNStopping the Engine Generator Storage GA-6RE/GA-6REA Preparation for Longterm StorageEngine Maintenance Schedule GA-6RE/GA-6REA Maintenance EngineSpark Plug Gap Engine Air CleanerGA-6HE Maintenance Battery GA-6RE Generator Wiring Diagram GA-6RE -WIRING Diagram GeneratorGA-6REA Generator Wiring Diagram GA-6REA -WIRING Diagram GeneratorEngine Troubleshooting GA-6RE/GA-6REA -TROUBLESHOOTING EngineWhite Generator Troubleshooting GA-6RE/GA-6REA -TROUBLESHOOTING GeneratorPage GA-6RE/GA-6REA Explanation of Code in Remarks Column How to read the marks and remarks used in this partsItems Found In the Remarks Column Items Found In the Items Number ColumnDescription GA-6RE/GA-6REA Suggested Spare PartsGA-6RE/GA-6REA Nameplate and Decals Part Name QTY Remarks GA-6RE/GA-6REA Generator Assy RECTIFIER, D3SB80 GA-6RE Control BOX Assy GA-6RE Control BOX Assy GA-6REA Control BOX Assy GA-6REA Control BOX Assy GA-6RE/GA-6REA Muffler Assy Muffler GA-6RE/GA-6REA Pipe Frame Assy GA-6RE GA-6RE/GA-6REA Battery Assy Battery Band Robin EH-360YS2420 Engine AIR Cleaner Assy Robin EH-360YS2420 Engine AIR Cleaner Assy Robin EH-360YS2420 Engine Crankcase Assy Valve Guide Robin EH-360YS2420 Engine Crankshaft and Piston Assy Crankshaft CP Robin EH-360YS2420 Engine Crankshaft and Piston AssyRobin EH-360YS2420 Engine Flywheel Assy Flywheel CP Robin EH-360YS2420 Engine Governor Assy Part Name QTY. Remarks Robin EH-360YS2420 Engine Intake and Exhaust Assy Camshaft CP Robin EH-360YS2420 Engine Cooling Starting Assy Label Trade Mark Robin EH-360YS2420 Engine Carburetor Assy Throttle Valve Robin EH-360YS2420 Engine Starter Assy Brush + Robin EH-360YS2420 Engine Solenoid Assy Solenoid AY Effective October 1, 2002 Terms and Conditions of Sale Parts Page Your Local Dealer is

GA-6RE, GA-6REA specifications

The Multiquip GA-6REA and GA-6RE are high-performance generators designed for a variety of applications, from construction sites to outdoor events. Renowned for their durability and reliability, these generators are engineered to meet the demands of professionals who require consistent power in challenging environments.

One of the standout features of the GA-6REA and GA-6RE is their robust engine performance. Equipped with a powerful Honda engine, these models deliver reliable power output, ensuring that tools and equipment run smoothly without interruptions. The generators have a fuel-efficient design, maximizing runtime and minimizing operational costs. With their impressive fuel tank capacity, users can expect extended operation time before needing to refuel.

Both models come equipped with advanced features to enhance ease of use and convenience. The digital control panel includes easy-to-read displays that provide real-time information about voltage, wattage, and runtime. This user-friendly interface allows operators to monitor performance seamlessly, making it easier to manage power consumption.

The GA-6REA specifically includes advanced noise-reduction technology, making it one of the quietest generators in its class. This feature is particularly beneficial for use in residential areas or noise-sensitive environments. The sound-dampening design ensures that it remains unobtrusive, allowing users to operate confidently without disturbing neighbors.

In terms of safety, Multiquip has designed the GA-6REA and GA-6RE with multiple protective features, including automatic low oil shutdown and overload protection. These safety mechanisms help prevent engine damage and ensure safe operation, making them ideal for both novice and experienced users.

The generators are also designed for portability, featuring a sturdy frame and ergonomic handles for easy transport. Their compact size allows for easy storage and maneuverability, whether on a construction site or during a weekend camping trip.

Durability is another critical characteristic of the GA-6REA and GA-6RE. With a rugged construction that withstands tough conditions, these generators are built to last. This reliability makes them a trusted choice for professionals in various sectors, ensuring they can perform their tasks without unexpected power failures.

In summary, the Multiquip GA-6REA and GA-6RE generators combine robust performance, advanced technology, and user-friendly features, making them an excellent choice for anyone seeking reliable power solutions for demanding situations. With their fuel efficiency, noise reduction, safety features, portability, and durability, these generators stand out as essential tools for professionals and enthusiasts alike.