Multiquip GA-6RE/GA-6REA Rules for Safe Operation, Read this manual

Page 8

GA-6RE/GA-6REA — RULES FOR SAFE OPERATION

 

DANGER

Read this manual!

 

 

 

Failure to follow instructions in this manual may lead to serious injury or even death! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only.

The following safety guidelines should always be used when operating the GA-6RE/GA-6REA Portable Generators:

GENERAL SAFETY

DO NOT operate or service this equipment before reading this entire manual.

This equipment should not be operated by persons under 18 years of age.

NEVER operate this equipment without proper protective clothing, shatterproof glasses, steel-toed boots and other protective devices required by the job.

NEVER operate this equipment when not

feeling well due to fatigue, illness or taking medicine.

NEVER operate this equipment under the influence of drugs or alcohol.

ALWAYS wear proper respiratory (mask), hearing and eye protection equipment when operating the generators.

Whenever necessary, replace nameplate, operation and safety decals when they become difficult read.

Manufacturer does not assume responsibility for any accident due to equipment modifications.

NEVER use accessories or attachments, which are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result.

NEVER touch the hot exhaust manifold, muffler or cylinder. Allow these parts to cool before servicing engine or generators.

The engine section of this generators requires an adequate free flow of cooling air. NEVER operate the generators in any enclosed or narrow area

where free flow of the air is restricted. If the air flow is

restricted it will cause serious damage to the generators or engine and may cause injury to people. Remember the generator's engine gives off DEADLY carbon monoxide gas.

ALWAYS refuel in a well-ventilated area, away from sparks and open flames.

ALWAYS use extreme caution when working with flammable liquids. When refueling, stop the engine and allow it to cool.DO NOT smoke around or near the machine. Fire or explosion could result from fuel vapors, or if fuel is spilled on a hot engine.

NEVER operate the generators in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death.

NEVER disconnect any "emergency or safety devices". These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death! Disconnection of any of these devices will void all warranties.

PAGE 8 — GA-6RE/GA-6REA A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (06/06/05)

Image 8
Contents Model GA-6RE/GA-6REA Page Heres HOW to GET Help Table of Contents Parts Ordering Procedures When ordering parts Please supply the following informationRespiratory Hazards GA-6RE/GA-6REA Safety Message Alert SymbolsBurn Hazards Rotating Parts Hazards GA-6RE/GA-6REA Safety Message Alert SymbolsEquipment Damage GA-6RE/GA-6REA Rules for Safe Operation Read this manualPower Cord Safety GA-6RE/GA-6REA Rules for Safe OperationDeath EmergenciesGA-6RE/GA-6REA Operation and Safety Decals Machine Safety DecalsGA-6RE/GA-6REA Specifications Generator Effects of Altitude and HeatSpecifications Engine GA-6RE/GA-6REA Specifications EngineGA-6RE/GA-6REA Dimensions DimensionsGA-6RE/GA-6REA General Information Single Phase Load 60 Hz Extension CablesGA-6RE/GA-6REA Controls and Indicators Generator ComponentsGA-6RE/GA-6REA Controls and Indicators V Full Power Switch Simplified Diagram Up PositionGA-6RE/GA-6REA Controls and Indicators FuelTank Fuel tank capacity is 5 gallons 19 litersGA-6RE/GA-6REA Generator Refueling Generator RefuelingGA-6RE/GA-6REA Installation Outdoor InstallationIndoor Installation MountingGA-6RE/GA-6REA Installation Connecting the GroundGeneral Inspection Prior to Operation Ground Power Tools GA-6RE/GA-6REA PREExtension Cable Main Circuit BreakerGA-6RE/GA-6REA PRE-INSPECTION Engine Before StartingEngine Oil Check Fuel CheckGA-6RE/GA-6REA Initial START-UP Engine Before Starting the EngineIdle Control Switch Off GA-6RE/GA-6REA Initial START-UP/GENERATOR OperationStopping the Engine Connecting the LoadGA-6RE/GA-6REA Generator OPERATION/SHUTDOWN GA-6RE/GA-6REA Preparation for Longterm Storage Generator StorageGA-6RE/GA-6REA Maintenance Engine Engine Maintenance ScheduleEngine Air Cleaner Spark Plug GapGA-6HE Maintenance Battery GA-6RE -WIRING Diagram Generator GA-6RE Generator Wiring DiagramGA-6REA -WIRING Diagram Generator GA-6REA Generator Wiring DiagramGA-6RE/GA-6REA -TROUBLESHOOTING Engine Engine TroubleshootingWhite GA-6RE/GA-6REA -TROUBLESHOOTING Generator Generator TroubleshootingPage How to read the marks and remarks used in this parts GA-6RE/GA-6REA Explanation of Code in Remarks ColumnItems Found In the Remarks Column Items Found In the Items Number ColumnGA-6RE/GA-6REA Suggested Spare Parts DescriptionGA-6RE/GA-6REA Nameplate and Decals Part Name QTY Remarks GA-6RE/GA-6REA Generator Assy RECTIFIER, D3SB80 GA-6RE Control BOX Assy GA-6RE Control BOX Assy GA-6REA Control BOX Assy GA-6REA Control BOX Assy GA-6RE/GA-6REA Muffler Assy Muffler GA-6RE/GA-6REA Pipe Frame Assy GA-6RE GA-6RE/GA-6REA Battery Assy Battery Band Robin EH-360YS2420 Engine AIR Cleaner Assy Robin EH-360YS2420 Engine AIR Cleaner Assy Robin EH-360YS2420 Engine Crankcase Assy Valve Guide Robin EH-360YS2420 Engine Crankshaft and Piston Assy Robin EH-360YS2420 Engine Crankshaft and Piston Assy Crankshaft CPRobin EH-360YS2420 Engine Flywheel Assy Flywheel CP Robin EH-360YS2420 Engine Governor Assy Part Name QTY. Remarks Robin EH-360YS2420 Engine Intake and Exhaust Assy Camshaft CP Robin EH-360YS2420 Engine Cooling Starting Assy Label Trade Mark Robin EH-360YS2420 Engine Carburetor Assy Throttle Valve Robin EH-360YS2420 Engine Starter Assy Brush + Robin EH-360YS2420 Engine Solenoid Assy Solenoid AY Effective October 1, 2002 Terms and Conditions of Sale Parts Page Your Local Dealer is

GA-6RE, GA-6REA specifications

The Multiquip GA-6REA and GA-6RE are high-performance generators designed for a variety of applications, from construction sites to outdoor events. Renowned for their durability and reliability, these generators are engineered to meet the demands of professionals who require consistent power in challenging environments.

One of the standout features of the GA-6REA and GA-6RE is their robust engine performance. Equipped with a powerful Honda engine, these models deliver reliable power output, ensuring that tools and equipment run smoothly without interruptions. The generators have a fuel-efficient design, maximizing runtime and minimizing operational costs. With their impressive fuel tank capacity, users can expect extended operation time before needing to refuel.

Both models come equipped with advanced features to enhance ease of use and convenience. The digital control panel includes easy-to-read displays that provide real-time information about voltage, wattage, and runtime. This user-friendly interface allows operators to monitor performance seamlessly, making it easier to manage power consumption.

The GA-6REA specifically includes advanced noise-reduction technology, making it one of the quietest generators in its class. This feature is particularly beneficial for use in residential areas or noise-sensitive environments. The sound-dampening design ensures that it remains unobtrusive, allowing users to operate confidently without disturbing neighbors.

In terms of safety, Multiquip has designed the GA-6REA and GA-6RE with multiple protective features, including automatic low oil shutdown and overload protection. These safety mechanisms help prevent engine damage and ensure safe operation, making them ideal for both novice and experienced users.

The generators are also designed for portability, featuring a sturdy frame and ergonomic handles for easy transport. Their compact size allows for easy storage and maneuverability, whether on a construction site or during a weekend camping trip.

Durability is another critical characteristic of the GA-6REA and GA-6RE. With a rugged construction that withstands tough conditions, these generators are built to last. This reliability makes them a trusted choice for professionals in various sectors, ensuring they can perform their tasks without unexpected power failures.

In summary, the Multiquip GA-6REA and GA-6RE generators combine robust performance, advanced technology, and user-friendly features, making them an excellent choice for anyone seeking reliable power solutions for demanding situations. With their fuel efficiency, noise reduction, safety features, portability, and durability, these generators stand out as essential tools for professionals and enthusiasts alike.