components (generator)
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
|
|
|
|
|
|
|
| |
|
|
|
| 120 |
|
|
|
|
| POWERED by |
| V 240 |
|
|
|
| |
| Honda Engines |
|
|
|
|
| ||
211052 |
|
|
|
|
|
| ||
OFF |
|
|
| AC VOLTMETER |
|
|
|
|
|
|
| VOLTOMETRE CA |
|
|
|
|
| MARCHE | ON MARCHE | ON | |||
AC CIRCUIT | ARRET | OFF ARRET | OFF | |||
| IDLE |
| OPERATION | |||
BREAKER | GFCI CIRCUIT |
| ||||
CONTROL | SWITCH | |||||
(for main) | BREAKER | |||||
INTERRUPTEUR DE INTERRUPTEUR DE | CONTROL | INTERRUPTEUR | ||||
COURANT PRINCIPAL | COURANT | DE RALENTI | DE OPERATION |
240V
START
BUTTON120V
BOUTON DE
DEMARRAGE
10
11
Figure 3. Generator Components
1.Main Breaker – This
2.GFCI Breaker – This single pole circuit breaker (120V, 15 amps) protects the GFCI receptacle.When starting the generator always have the circuit breaker placed in the "OFF" position.
3.Idle Control Switch – The generator is provided with an automatic idle control device for noise suppression and reduced fuel consumption.
The automatic idle control automatically engages under a
4.Operation Switch – Place switch in the "ON" position (up) for normal operation. To
5.
6.Start Button – Press this pushbutton switch to start the generator.
7.GFCI Duplex Receptacle – NEMA
8.120V Output Receptacle – NEMA
9.240V Output Receptacle – NEMA
10.Ground – This ground connection point should be connect to a good earth ground (ground rod).
11.Battery – This generator is equipped with a 12 VDC battery. Replace with only recommended type battery.