operation
NOTICE
DO NOT pull the starter rope all the way to the end.
DO NOT release the starter rope after pulling. Allow it to rewind as soon as possible..
7.If the engine has started, slowly return the choke lever (Figure 13) to the OPEN position. If the engine has not started repeat steps 1 through 8.
8.Before the generator is placed into operation, run the engine for
9.Place idle control switch (Figure 17) in the OFF (down) position.This will allow the engine speed to run at about 3600 RPM's.
10.Place main circuit breaker (Figure 19) in the ON position.
Figure 19. Main Circuit Breaker (ON)
11.Place GFCI circuit breaker (Figure 20) in the ON position.
Figure 17. Idle Control Switch (OFF)
NOTICE
Placing the idle control switch in the OFF position (Figure 17) allows the engine to operate at a maximum speed of about 3600 RPM's.
When the idle control switch (Figure 18) is placed in the up position (ON), the generator will run at idle speed (2200 RPM's) until a load is applied, at that time the engine speed will increase to 3600 RPM's as long as a load is being applied.
When the load is not in use, the engine speed will drop back to the idle mode after about 3 seconds.
Figure 20. GFCI Circuit Breaker (ON)
12.Read voltmeter on front panel of generator (Figure 21) and verify that 120 VAC is displayed. Using an external voltmeter as shown in Figure 21, verify that 120 VAC is present at the 120V
Figure 21. 120V/GFCI Receptacles
Figure 18. Idle Control switch (ON)