operation
This section is intended to assist the operator with the initial
Before Starting the Engine
1.Be sure to disconnect all electrical loads from the generator prior to starting the engine.
2.NEVER start the engine with the main circuit breaker in the ON position.Always place circuit breaker (Figure 10) in the OFF position before starting.
Figure 10. Main Circuit Breaker (OFF)
3.NEVER start the engine with the GFCI circuit breaker in the ON position. Always place circuit breaker (Figure 11) in the OFF position before starting. engine
Figure 11. GFCI Circuit Breaker (OFF)
Starting the Engine
1.Place the engine fuel valve lever (Figure 12) in the ON position.
Figure 12. Engine Fuel Valve Lever (ON)
2.Place the choke lever (Figure 13) in the CLOSED position if starting a cold engine.
Figure 13. Choke Lever
3.Place the choke lever (Figure 13) in the OPEN position if starting a warm engine or the temperature is warm.
4.Place the generator's operation switch (Figure 14) in the ON position.
Figure 14. Operation Switch (ON)
5.Press the generator's pushbutton start switch (Figure 15) and listen for the engine to start. If the battery is not installed proceed to step 6.
Figure 15. Start Pushbutton Switch
6.Grasp the starter grip (Figure 16) and slowly pull it out. The resistance becomes the hardest at a certain position, corresponding to the compression point. Pull the starter grip briskly and smoothly for starting.