Multiquip DCA125USJ Air Removal, Check Oil Level, Replacing Oil Filter, Replacing Fuel Filter

Page 41

Air Removal

If air enters the fuel injection system of a diesel engine, starting becomes impossible. After running out of fuel, or after disassembling the fuel system, bleed the system according to the following procedure. See the John Deere Engine Manual for details.

Check Oil Level

Check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe damage to the engine. Make sure the generator is level. The oil level must be between the two notches on the dipstick as shown in Figure 33.

Replacing Oil Filter

Remove the old oil filter.

Apply a film of oil to the gasket on the new oil filter.

Install the new oil filter.

After the oil cartridge has been replaced, the engine oil will drop slightly. Run the engine for a while and check for leaks before adding more oil if needed. Clean excessive oil from engine.

Replacing Fuel Filter

Replace the fuel filter cartridge with new one every 500 hours or so.

Loosen the drain plug at the lower top of the fuel filter. Drain the fuel in the fuel body together with the mixed water. DO NOT spill the fuel during disassembly.

Vent any air.

DCA-125USJ — MAINTENANCE

Flushing Out Radiator and Replacing Coolant

Open both cocks located at the crankcase side and at the lower part of the radiator and drain coolant.Open the radiator cap while draining. Remove the overflow tank and drain.

Check hoses for softening and kinks. Check clamps for signs of leakage.

Flush the radiator by running clean tap water through radiator until signs of rust and dirt are removed. DO NOT clean radiator core with any objects, such as a screwdriver.

Tighten both cocks and replace the overflow tank.

Replace with coolant as recommended by the engine manufaturer.

Close radiator cap tightly.

WARNING - BURN HAZARDS

Allow engine to cool when flushing out radiator. Flushing the radiator while hot could cause serious burns from water or steam.

Generator Storage

For longe term storage of the generator the following is recommended:

Fill the fuel tank completely. Treat with a fuel stabilizer if necessary.

Completely drain the oil from the crankcase and refill if necessary with fresh oil.

Clean the entire generator, internal and external.

Cover the generating set and store in a clean, dry place.

Disconnect the battery.

Make sure engine coolant is at proper level.

If generator is mounted on a trailer, jack trailer up and place on blocks so tires do not touch the ground or block and completely remove the tires.

DCA-125USJ — OPERATION AND PARTS MANUAL — REV. #2 (01/27/11) — PAGE 41

Image 41
Contents Model DCA125USJ 2 DCA-125USJ Operation and Parts Manual REV. #2 01/27/11 DCA-125USJ Operation and Parts Manual REV. #2 01/27/11 Table of Contents Ordering parts has never been easier Parts Ordering ProceduresGenerator Specifications DCA-125USJ SpecificationsDimensions DCA-125USJ Dimensions TOP, Side and FrontSafety Messages DCA-125USJ Safety Information„ Always know the location of the nearest DCA-125USJ Safety Informationfire extinguisher first aid kitIf operating in speed ranges above the maximum allowable Before servicing equipmentFrom fuel vapors or if fuel is spilled on a hot engine „ Never use fuel as a cleaning agent3ECURE Portable Power Cables in Cable Tray with TIE wraps „ Never use gas piping as an electrical ground Device. All installations should beDCA-125USJ Safety Information DCA-125USJ Generator Decals DCA-125USJ Generator Decals Typical Generator Grounding Application DCA-125USJ InstallationOutdoor Installation DCA-125USJ InstallationIndoor Installation MountingEngine Operating Panel DCA-125USJ Series Familiarization GeneratorGenerator Control Panel Control BoxGenerator Major Components DCA-125USJ Major Components20 DCA-125USJ Operation and Parts Manual REV. #2 01/27/11 DCA-125USJ Generator Control Panel DCA-125USJ Engine Operating Panel DCA-125USJ Engine Operating Panel Output Terminal Familiarization DCA-125USJ Output Terminal Panel FamiliarizationTwist Lock Dual Voltage 120/240 VAC Receptacles 120VAC Gfci ReceptaclesBlower Fan Connecting LoadsThree Phase Load Single Phase LoadDCA-125USJ Load Application Motors and motor-drivenGenerator OutputVoltages Voltage Selector SwitchGenerator Amperage Gfci Receptacle Load CapabilityReading Amperage How to Read the OutputTerminal GaugesDCA-125USJ Gauge Reading Uvwo Terminal Output Voltages DCA-125USJ Output Terminal Panel Connections3Ø 240/139 Output Terminal Lug Voltages 3Ø 208V/1Ø120V Output Terminal Lug Voltages1Ø 240V/120V Output Terminal Lug Voltages 3Ø 480/277 Output Terminal Lug VoltagesCircuit Breakers DCA-125USJ PRE-SETUPLubrication Oil Fuel CheckRefueling Refueling ProcedureAir Cleaner Fan Belt Tension Cleaning the RadiatorOperation FreezingWeather Must be less than 50%Battery Cable Installation BatteryWiring AlternatorEngines exhaust contains harmful emissions Before StartingDirect exhaust away from nearby personnel Starting ManualFrequency Meter Hz Is placed in the Auto position Starting Auto ModePlace the Mpec Control Switch in the Auto position Emergency Shutdown Procedure Normal Shutdown ProcedureDCA-125USJ Maintenance Check Oil Level Air RemovalReplacing Oil Filter Replacing Fuel FilterTo ensure adequate starting Battery chargerBrake Adjustment DCA-125USJ -TRAILER Brakes MaintenanceBrakes Hydraulic Surge BrakesTire Wear/Inflation Tires/Wheels/Lug NutsSuspension Start all wheel lug nuts by hand DCA-125USJ -TRAILER MaintenanceLug Nut Torque Requirements DCA-125USJ -TRAILERWIRING Diagram Generator Wiring Diagram DCA-125USJ Generatorwiring DiagramDCA-125USJ Enginewiring Diagram DCA-125USJ -TROUBLESHOOTING Generator Engine Controller Troubleshooting Mpec DCA-125USJ -TROUBLESHOOTING Engine ControllerDCA-125USJ Operation and Parts Manual REV. #2 01/27/11 QTY. Column DCA-125USJ Explanation of Code in Remarks ColumnQty Description DCA-125USJ Suggested Spare PartsDCA-125USJ Generator Assy DCA-125USJ Generator Assy DCA-125USJ Control BOX Assy 0330000180 M32130007020601808823 LAF3630010393P58 DCA-125USJ Operation and Parts Manual REV. #2 01/27/11 DCA-125USJ Control BOX Assy DCA-125USJ Engine and Radiator Assy 0602041292 M3923200054RE504836 0602042594Engine & Radiator Assy 0602022563 06055151970602022561 0603306590DCA-125USJ Outputterminal Assy DCA-125USJ Outputterminal Assy DCA-125USJ Battery Assy 4D-2 0602220196M9310500404 M9103000504DCA-125USJ Muffler Assy 0017112030 M3330100402M3333000903 M3333200304DCA-125USJ Fueltank Assy 0605505070 M33630014020605501074 0605516090Enclosure #1 Assy DCA-125USJ Enclosure #1 AssyM3363300303 M34130018120016910030 060330679774 DCA-125USJ Operation and Parts Manual REV. #2 01/27/11 24A M3493201204 24A M34932006140010114040 25A 0030014000Enclosure #2 Assy DCA-125USJ Enclosure #2 AssyM3443000812 M3443000802M3493303203 M3443000904DCA-125USJ Rubber Seals Assy 0229201130 02292008700229201240 0228900660DCA-125USJ Nameplate and Decals Assy M15000020 M1550000204M1550000703 M15000070Freight Policy Terms and Conditions of Sale PartsDCA-125USJ Operation and Parts Manual REV. #2 01/27/11 HERE’S HOW to GET Help

DCA125USJ specifications

The Multiquip DCA125USJ is a robust, high-performance generator designed to meet the diverse needs of various industries, including construction, events, and emergency backup. This generator boasts a compact size and impressive output, making it a reliable choice for both temporary and permanent power solutions.

At the heart of the DCA125USJ is a powerful diesel engine, providing an impressive 125 kVA output. This engine is engineered for efficiency, ensuring that the generator can continuously deliver reliable power while maintaining low operational costs. The generator operates at low RPM, which not only extends the engine's lifespan but also reduces noise levels, making it ideal for urban environments and sensitive locations.

One of the standout features of the DCA125USJ is its advanced electronic control system. This technology allows for seamless monitoring and management of the generator's performance, ensuring optimal operation. The control panel is user-friendly, offering real-time data on voltage, frequency, and operating hours, which simplifies maintenance and troubleshooting.

The DCA125USJ is equipped with a sturdy, weather-resistant enclosure that protects it from the elements, making it suitable for outdoor applications. This enclosure also contributes to noise reduction, ensuring quieter operation compared to traditional generators. Additionally, its compact design allows for easy transport and installation, making it a versatile option for various job sites.

Safety is a top priority in the design of the DCA125USJ. It features multiple safety mechanisms, such as an automatic shut-off system that activates in the event of low oil pressure or overheating, protecting the generator and prolonging its operational life.

Moreover, the DCA125USJ is compliant with rigorous emissions standards, making it an environmentally responsible choice. It offers options for multiple voltage outputs, which adds to its adaptability for different applications, from powering heavy machinery to providing electricity for small tools.

In summary, the Multiquip DCA125USJ stands out for its powerful diesel engine, state-of-the-art electronic controls, robust construction, and focus on safety and efficiency. Whether used in construction, outdoor events, or as a backup power source, the DCA125USJ is engineered to deliver reliable performance in a user-friendly package. This makes it a top contender for anyone needing dependable generator capabilities.