MP2 MASONRY SAW — PRE-SETUP (ELECTRIC MOTORS)
Connecting the Power (Figure 10)
1.Place the power ON/OFF switch (Figure 11) in the OFF position (down).
Figure 11. Power ON/OFF Switch (OFF)
2.Connect an extension cord (Figure 13) of adequate current carrying capacity to the power plug on the electric motor.
DANGER - Electrocution Hazard
NEVER grab or touch a live power cord with wet hands, the possibility exists of electrical shock, ectrocution, and even death!
NEVER use a damaged or worn extension cable when connecting
to a power source. Defective cables may cause damage to the saw's electric motor or electrical shock.
CAUTION - Grounding Electric Motors
ALWAYS use a grounded
4.The MP2 Masonry Saw is now ready for wet cutting.
Dry Cutting (Electric Saws Only)
1.
CAUTION - Dry Cutting & Water Pump
NEVER dry cut with the pump connected to a AC power source. Running the pump dry will damage the pump. Always disconnect the pump's power cord when dry cutting.
2.The MP2 Masonry Saw is now ready for dry cutting.
CAUTION - Dry Cutting & Water Pump
MAKE CERTAIN that the correct size extension cord is used. Undersize wires will burn out motors. Use Table 4 to determine the correct extension cord size.
TABLE 4. EXTENSION CORD SIZES
MOTOR | VOLTAGE | 50' | 75' | 100' | |
LONG | LONG | LONG | |||
|
| ||||
|
|
|
|
| |
5HP - SINGLE PHASE | 230 | No. 10 | No. 8 | No. 6 | |
|
|
|
|
| |
5HP - 3 PHASE | 230 | No. 12 | No. 10 | No.. 8 | |
|
|
|
|
| |
5HP - 3 PHASE | 460 | No. 14 | No. 12 | No. 10 | |
|
|
|
|
| |
7.5HP - 3 PHASE | 230 | No. 10 | No. 8 | No. 6 | |
|
|
|
|
| |
7.5HP - 3 PHASE | 460 | No. 12 | No. 10 | No. 8 | |
|
|
|
|
|
PAGE 22 — MQ MP2 MASONRY SAW — OPERATION MANUAL — REV. #2 (03/12/13)