Multiquip MQ GA-2.9R- Rules for Safe Operation, Read this manual

Page 10

MQ GA-2.9R— RULES FOR SAFE OPERATION

 

DANGER

Read this manual!

 

 

 

Failure to follow instructions in this manual may lead to serious injury or even death! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only.

The following safety guidelines should always be used when operating the MQ GA-2.9R Portable Generator:

GENERAL SAFETY

DO NOT operate or service this equipment before reading this entire manual.

This equipment should not be operated by persons under 18 years of age.

NEVER operate this equipment without proper protective clothing, shatterproof glasses, steel-toed boots and other protective devices required by the job.

NEVER operate this equipment when not

feeling well due to fatigue, illness or taking medicine.

NEVER operate this equipment under the influence of drugs or alcohol.

ALWAYS wear proper respiratory (mask), hearing and eye protection equipment when operating the generator.

Whenever necessary, replace nameplate, operation and safety decals when they become difficult read.

Manufacturer does not assume responsibility for any accident due to equipment modifications.

NEVER use accessories or attachments, which are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result.

NEVER touch the hot exhaust manifold, muffler or cylinder. Allow these parts to cool before servicing engine or generator.

The engine section of this generator requires an adequate free flow of cooling air. NEVER operate the generator in any enclosed or narrow

area where free flow of the air is restricted. If the air flow is restricted it will cause serious damage to the generator or engine and may cause injury to people. Remember the generator's engine gives off DEADLY carbon monoxide gas.

ALWAYS refuel in a well-ventilated area, away from sparks and open flames.

ALWAYS use extreme caution when working with flammable liquids. When refueling, stop the engine and allow it to cool.DO NOT smoke around or near the machine. Fire or explosion could result from fuel vapors, or if fuel is spilled on a hot engine.

NEVER operate the generator in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death.

NEVER disconnect any "emergency or safety devices". These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death! Disconnection of any of these devices will void all warranties.

PAGE 10 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)

Image 10
Contents Model GA-2.9R Page Heres HOW to GET Help Table of Contents Parts Ordering Procedures When ordering parts Please supply the following informationMQ GA-2.9R- Dimensions DimensionsSpecifications Effects of Altitude and HeatBurn Hazards MQ GA-2.9R- Safety Message Alert SymbolsRespiratory Hazards Equipment Damage Rotating Parts HazardsMQ GA-2.9R- Rules for Safe Operation Read this manualMQ GA-2.9R Rules for Safe Operation MQ GA-2.9R Rules for Safe Operation EmergenciesMachine Safety Decals Operation and Safety DecalsControl Panel MQ GA-2.9R General InformationMQ GA-2.9R Familarization Excitation SystemMQ GA-2.9R- Load Application Single Phase LoadExtension Cables MQ GA-2.9R Controls and Indicators Generator Controls and ComponentsPlaced in the OFF position MQ GA-2.9R Generator Refueling Generator RefuelingIndoor Installation MQ GA-2.9R InstallationOutdoor Installation MountingMQ GA-2.9R Installation Connecting the GroundExtension Cable General Inspection Prior to Operation Ground Power ToolsMQ GA-2.9R- PRE-INSPECTION Main Circuit BreakerEngine Oil Check MQ GA-2.9R PRE-INSPECTION EngineBefore Starting Fuel CheckMQ GA-2.9R Initial START-UP Engine Before Starting the EngineMQ GA-2.9R- Initial START-UP ENGINE/OPERATION Stopping The EngineMQ GA-2.9R Preparation for Long -TERM Storage Generator StorageMQ GA-2.9R Maintenance Engine Engine Maintenance ScheduleCleaning the Fuel Strainer MQ GA-2.9R Maintenance EngineMaintenance MQ GA-2.9R -WIRING Diagram Generator/Engine Wiring DiagramMQ GA-2.9R -TROUBLESHOOTING Engine Engine TroubleshootingMQ GA-2.9R -TROUBLESHOOTING Engine WhiteMQ GA-2.9R -TROUBLESHOOTING Generator MQ GA-2.9R Explanation of Code in Remarks Column How to read the marks and remarks used in this parts bookItems Found In the Items Number Column MQ GA-2.9R Suggested Spare Parts To 3 UnitsMQ GA-2.9R Name Plate and Decals MQ GA-2.9R Name Plate and Decals Part Name QTY RemarksMQ GA-2.9R Generator Assy SET BOLT, Rotor MQ GA-2.9R Control BOX Assy Control BOX MQ GA-2.9R Pipe Frame Assy Part Name Robin EX170D20210 Crankcase Assy Robin EX170D20210- Crankcase Assy Robin EX170D20210 Crankshaft and Piston Assy Crankshaft Assy Robin EX170D20210 Governor Assy Part Name QTY. Remarks Robin EX170D20210 Intake and Exhaust Assy PIN, CAM Shaft Robin EX170D20210 AIR Cleaner Assy Robin EX170D20210 AIR Cleaner Assy Robin EX170D20210 Cooling Starting Assy Blower Housing CP Robin EX170D20210 -CARBURETOR Assy Robin EX170D20210 Carburetor Assy Robin EX170D20210 Flywheel Assy Part Name QTY Robin EX170D20210 Electric Device Assy OIL Sensor CP Terms and Conditions of Sale Parts FreightpolicyPage Your Local Dealer is