Multiquip manual MQ GA-2.9R -TROUBLESHOOTING Generator

Page 31

MQ GA-2.9R —TROUBLESHOOTING (GENERATOR)

Practically all generator breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, please take a remedial action following the

diagnosis based on the Generator Troubleshooting (Table 7) information shown below and on the preceding page. If the problem cannot be remedied, please leave the unit just as it is and consult our company's business office or service plant.

TABLE 7. GENERATOR TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

Low voltage

Engine speed too low?

Raise engine speed to rated RPM.

 

 

 

 

AC voltmeter not working?

Replace AC voltmeter.

 

 

 

 

Control box internal wiring

Check control box wiring.

 

malfunction?

 

 

 

 

Low voltage. Engine speed

Defective ignition coil?

Check red and green ignition wires. Replace ignition wires if

normal 3650 RPM (unloaded),

 

necessary.

2500 RPM (idle)

 

 

Rotor winding malfunction?

Check or replace rotor.

 

 

 

 

 

Stator winding malfunction?

Check or replace stator.

 

 

 

 

Breaker malfunction?

Check or replace CB1.

 

 

 

Voltage output too high.

Engine speed too high?

Lower engine speed to rated RPM.

 

 

 

Voltage output too high. Engine

Control box internal wiring

Check control box wiring.

speed normal 3650 RPM

malfunction

 

(unloaded), 2500 RPM (idle)

 

 

 

 

 

Circuit breaker will not turn on

Defective circuit breaker?

Replace circuit breaker.

"NO LOAD"

 

 

 

 

 

Circuit breaker will turn on

Overload?

Reduce load or replace breaker.

 

 

"LOADED" but trips immediately.

Load circuit is shorted?

Check load circuit for short.

 

 

 

 

Does not accelerate from low to

Stuck solenoid?

Check solenoid.

high "NO LOAD"

 

 

 

 

 

Does not accelerate from low to

Control box interal wiring

Check control box wiring.

high "LOAD ACTIVE

defective?

 

 

 

 

 

Defective rotor windings?

Check or replace rotor.

 

 

 

Does not decelerate no

Defective solenoid?

Check or replace solenoid.

 

 

"VOLTAGE OUTPUT".

Defective idle control device?

Check or replace idle control device.

 

 

 

 

 

Defective solenoid?

Check or replace idle control device.

 

 

 

 

Control box wiring malfunction?

Check control box wiring, replace any defective components.

Does not decelerate but has

 

 

Defective solenoid?

Check or replace solenoid.

"VOLTAGE OUTPUT".

 

 

 

Idle control device malfunction?

Check or replace idle control device.

 

 

 

MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 31

Image 31
Contents Model GA-2.9R Page Heres HOW to GET Help Table of Contents When ordering parts Please supply the following information Parts Ordering ProceduresDimensions MQ GA-2.9R- DimensionsEffects of Altitude and Heat SpecificationsBurn Hazards MQ GA-2.9R- Safety Message Alert SymbolsRespiratory Hazards Rotating Parts Hazards Equipment DamageRead this manual MQ GA-2.9R- Rules for Safe OperationMQ GA-2.9R Rules for Safe Operation Emergencies MQ GA-2.9R Rules for Safe OperationOperation and Safety Decals Machine Safety DecalsExcitation System MQ GA-2.9R General InformationMQ GA-2.9R Familarization Control PanelMQ GA-2.9R- Load Application Single Phase LoadExtension Cables Generator Controls and Components MQ GA-2.9R Controls and IndicatorsPlaced in the OFF position Generator Refueling MQ GA-2.9R Generator RefuelingMounting MQ GA-2.9R InstallationOutdoor Installation Indoor InstallationConnecting the Ground MQ GA-2.9R InstallationMain Circuit Breaker General Inspection Prior to Operation Ground Power ToolsMQ GA-2.9R- PRE-INSPECTION Extension CableFuel Check MQ GA-2.9R PRE-INSPECTION EngineBefore Starting Engine Oil CheckBefore Starting the Engine MQ GA-2.9R Initial START-UP EngineStopping The Engine MQ GA-2.9R- Initial START-UP ENGINE/OPERATIONGenerator Storage MQ GA-2.9R Preparation for Long -TERM StorageEngine Maintenance Schedule MQ GA-2.9R Maintenance EngineCleaning the Fuel Strainer MQ GA-2.9R Maintenance EngineMaintenance Generator/Engine Wiring Diagram MQ GA-2.9R -WIRING DiagramEngine Troubleshooting MQ GA-2.9R -TROUBLESHOOTING EngineWhite MQ GA-2.9R -TROUBLESHOOTING EngineMQ GA-2.9R -TROUBLESHOOTING Generator MQ GA-2.9R Explanation of Code in Remarks Column How to read the marks and remarks used in this parts bookItems Found In the Items Number Column To 3 Units MQ GA-2.9R Suggested Spare PartsMQ GA-2.9R Name Plate and Decals Part Name QTY Remarks MQ GA-2.9R Name Plate and DecalsMQ GA-2.9R Generator Assy SET BOLT, Rotor MQ GA-2.9R Control BOX Assy Control BOX MQ GA-2.9R Pipe Frame Assy Part Name Robin EX170D20210 Crankcase Assy Robin EX170D20210- Crankcase Assy Robin EX170D20210 Crankshaft and Piston Assy Crankshaft Assy Robin EX170D20210 Governor Assy Part Name QTY. Remarks Robin EX170D20210 Intake and Exhaust Assy PIN, CAM Shaft Robin EX170D20210 AIR Cleaner Assy Robin EX170D20210 AIR Cleaner Assy Robin EX170D20210 Cooling Starting Assy Blower Housing CP Robin EX170D20210 -CARBURETOR Assy Robin EX170D20210 Carburetor Assy Robin EX170D20210 Flywheel Assy Part Name QTY Robin EX170D20210 Electric Device Assy OIL Sensor CP Freightpolicy Terms and Conditions of Sale PartsPage Your Local Dealer is