OUTPUT TERMINAL PANEL FAMILIARIZATION

100 VAC GFCI Receptacles

There are two 100 VAC, 20 amp GFCI (Duplex Nema 5-20R) receptacles provided on the output terminal panel. These receptacles can be accessed in any voltage selector switch position. Each receptacle is protected by a 20 amp circuit breaker.These breakers are located directly above the GFCI receptacles. Remember the load output (current) of both GFCI receptacles is dependent on the load requirements of the U, V, and W output terminal lugs.

Pressing the reset button resets the GFCI receptacle after being tripped. Pressing the test button (See Figure 7) in the center of the receptacle will check the GFCI function. Both receptacles should be tested at least once a month.

Figure 7. G.F.C.I. Receptacle

Twist Lock Dual Voltage 100/200 VAC Receptacles

There are three 100/200V, 50 amp auxiliary twist-lock (CS- 6369) receptacles (Figure 8) provided on the output terminal panel. These receptacles can only be accessed when the voltage selector switch is placed in the single- phase 240/120 position.

Figure 8. 100/200V Twist-Lock Auxiliary

Receptacles

Each auxiliary receptacle is protected by a 50 amp circuit breaker. These breakers are located directly above the GFCI receptacles. Remember the load output (current) on all three receptacles is dependent on the load requirements of the Output Terminal Lugs.

Turn the voltage regulator control knob (Figure 9) on the control panel to obtain the desired voltage.Turning the knob clockwise will increase the voltage, turning the knob counter-clockwise will decrease the voltage.

Figure 9. Voltage Regulator Control Knob

DCA45SSIU3 50 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #2 (12/19/08) — PAGE 23

Image 23
Contents This Manual Must Accompany the Equipment AT ALL Times Model DCA45SSIU3Proposition 65 Warning Administrator Reporting Safety DefectsDCA45SSIU3 Generator Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety Information Always know the location of the nearest General SafetyGenerator Safety Before servicing equipment Engine SafetyTowing Safety Fuel Safety The electrical voltage required to Electrical SafetyGrounding Safety Power Cord/Cable SafetyEnvironmental Safety Battery SafetyGenerator Specifications SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationGenerator Grounding Outdoor InstallationIndoor Installation MountingGeneral Information Item no Major ComponentsOwing from the U,V, and W Output Terminal Lugs to the load Generator Control PanelPage Fuel Gauge Indicates amount of diesel fuel available Engine Operating PanelPage Terminal legs O and Ground are considered bonded grounds Output Terminal Panel FamiliarizationOutput Terminal Familiarization 200V Twist-Lock Auxiliary Receptacles VAC Gfci ReceptaclesOver Current Relay Connecting LoadsLoad Application Single Phase LoadThree Phase Load Generator Output Voltages Voltage Selector SwitchVoltage Selector Switch Locking Button Generator OutputsReading Amperage Generator OUTPUTS/GAUGE ReadingReading Voltage 3Ø-200V/1Ø-115V Uvwo Terminal Output Voltages Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø-220/127 Uvwo Terminal Output Voltages1Ø-200/100V Uvwo Terminal Output Voltages 3Ø-440/254V Uvwo Terminal Output VoltagesFuel Check INSPECTION/SETUPCircuit Breakers Lubrication OILOnly use #2 diesel fuel when refueling Refueling ProcedureOperation in Freezing Weather Cleaning the RadiatorAIR Cleaner FAN Belt Tension Coolant ANTIFREEZE/SUMMER COOLANT/ WaterAlternator BatteryBattery Cable Installation WiringEngine’s exhaust contains harmful emissions Generator START-UP ProcedureBefore Starting StartingFrequency Meter Never stop the engine suddenly except in an emergency Generator SHUT-DOWN ProceduresNormal Shutdown Procedure Emergency Shutdown ProcedureAir Cleaner with Dust Indicator MaintenanceGeneral Inspection AIR Cleaner AIR Removal Fuel AdditionFuel Tank Inspection Flushing OUT Radiator and Replacing Coolant Radiator CleaningCheck OIL Level Replacing Oil FilterCoupler Type of hitch used on the trailer for towing Trailer MaintenanceTrailer Maintenance Actuator Brake AdjustmentBrakes Hydraulic Surge BrakesSuspension TIRES/WHEELS/LUG NutsTire Wear/Inflation Never use an pneumatic air gun to tighten wheel lug nuts Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramTroubleshooting Generator Explanation of Code in Remarks Column Sample Parts ListTo 3 units Suggested Spare PartsGenerator Assy 0042510000 B31101002028051070003 0010310035Control BOX Assy 0601870490 M12130008020601870431 FG3110WS02 3P 110AEngine and Radiator Assy 0030010000 M19232000548970497081 0605000048Engine and Radiator Assy M9300000003 01500000180199900700 0605515106Output Terminal Assy 0039310000 M1230700103M9220100204 M9220100104Engine Operating Panel Assy 2A# 0601810245 89704441808944024980 0602103092Battery Assy M9103000304 0602220187627MFD M9310500014Muffler Assy M1333001903 M3330100902M1330100703 0016910025Fuel Tank Assy M9310500104 M13630016020605505070 M1363200104Enclosure Assy M1493106703 M1413002902M1413400004 M1423001902Enclosure Assy Part Name QTY Rubber Seals Assy Seal Rubber Nameplate and Decals Assy M1550002103 M1550000204M1550001304 M1550002003Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

CDA45SSIU3 specifications

The Multiquip CDA45SSIU3 is a versatile and powerful piece of equipment primarily designed for the construction and industrial sectors. As part of Multiquip's range of durable and reliable construction machinery, the CDA45SSIU3 is engineered to meet the demands of various tasks, including compacting soil, asphalt, and granular materials.

One of the standout features of the CDA45SSIU3 is its robust, high-performance engine. Powered by a reliable and efficient fuel system, the machine ensures optimal performance even under the heaviest loads. This not only improves productivity but also reduces fuel consumption, resulting in significant cost savings for contractors and operators.

The CDA45SSIU3 is equipped with advanced vibration technology, which provides exceptional compaction capabilities. Its dual-pump system delivers consistent performance, enabling operators to achieve the desired density in various soil types. This feature enhances the efficiency of the compaction process, making it ideal for preparing foundations, roadways, and other critical infrastructure.

Another notable characteristic of the CDA45SSIU3 is its user-friendly design. The machine comes with an intuitive control panel that allows operators to easily manage its functions. This ease of use reduces the learning curve for new operators, allowing them to quickly become proficient and maximizing productivity on job sites.

Durability is a key consideration in the design of the CDA45SSIU3. Constructed with high-quality materials, it withstands the rigors of demanding environments. The heavy-duty frame and components ensure longevity and consistent performance over time while minimizing maintenance requirements.

Additionally, the CDA45SSIU3 is designed with mobility in mind. Its compact dimensions and lightweight structure make it easy to transport between job sites. This portability ensures that operators can efficiently transition from one project to another without unnecessary delays.

Safety features are also a priority with the CDA45SSIU3. Equipped with safeguards that prevent accidental operation and enhance operator safety, the machine provides peace of mind while in use.

In summary, the Multiquip CDA45SSIU3 stands out as a powerful, reliable, and efficient solution for compaction tasks in construction and industrial applications. Its advanced engine, vibration technology, user-friendly controls, durable construction, and safety features make it an excellent choice for professionals seeking high-performance equipment. With the CDA45SSIU3, users can expect enhanced productivity, reduced operating costs, and reliable performance in various conditions.