Multiquip CDA45SSIU3 manual Generator Outputs, Generator Output Voltages, Voltage Selector Switch

Page 26

GENERATOR OUTPUTS

GENERATOR OUTPUT VOLTAGES

A wide range of voltages are available to supply voltage for many different applications.Voltages are selected by using the voltage selector switch (Figure 12). To obtain some of the voltages as listed in Table 7 (see below) will require a

ne adjustment using the voltage regulator (VR) control knob located on the control panel.

Voltage Selector Switch

The voltage selector switch (Figure 12) is located above the output terminal panel’s Hard Wire Hook-up Panel. It has been provided for ease of voltage selection.

Figure 12. Voltage Change-Over Board

Voltage Selector Switch Locking Button

The voltage selector switch has a locking button to protect the generator and load from being switched while the engine is running.To lock the voltage selector switch, press and hold the red button located at the bottom of the switch.

CAUTION

NEVER change the position of the voltage selector switch while the engine is running. ALWAYS place circuit breaker in the OFF position before selecting voltage.

Table 7. Voltages Available

Three Phase

200V

220V

416V

440V

(Switchable)

 

 

 

 

 

 

 

 

 

Single Phase

115V

127V

240V

254V

(Switchable)

 

 

 

 

 

 

 

 

 

Maximum Amps

Table 8 shows the maximum amps the generator can provide. DO NOT exceed the maximum amps as listed..

Table 8. Generator Maximum Amps

Rated Voltage

Maximum Amps

 

 

Single Phase 100 Volt

98 amps (4 wire)

 

 

Single Phase 200 Volt

48 amps (4 wire)

 

 

Three Phase 200 Volt

104 amps

 

 

Three Phase 400 Volt

52 amps

 

 

PAGE 26 — DCA45SSIU3 50 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #2 (12/19/08)

Image 26
Contents Model DCA45SSIU3 This Manual Must Accompany the Equipment AT ALL TimesProposition 65 Warning Reporting Safety Defects AdministratorTable of Contents DCA45SSIU3 GeneratorParts Ordering Procedures Ordering parts has never been easierSafety Information Safety Messages Always know the location of the nearest General SafetyGenerator Safety Engine Safety Before servicing equipmentFuel Safety Towing SafetyPower Cord/Cable Safety Electrical SafetyGrounding Safety  The electrical voltage required toBattery Safety Environmental SafetySpecifications Generator SpecificationsDimensions DimensionsInstallation Typical Generator Grounding ApplicationMounting Outdoor InstallationIndoor Installation Generator GroundingGeneral Information Major Components Item noGenerator Control Panel Owing from the U,V, and W Output Terminal Lugs to the loadPage Engine Operating Panel Fuel Gauge Indicates amount of diesel fuel availablePage Terminal legs O and Ground are considered bonded grounds Output Terminal Panel FamiliarizationOutput Terminal Familiarization VAC Gfci Receptacles 200V Twist-Lock Auxiliary ReceptaclesConnecting Loads Over Current RelayLoad Application Single Phase LoadThree Phase Load Generator Outputs Voltage Selector SwitchVoltage Selector Switch Locking Button Generator Output VoltagesReading Amperage Generator OUTPUTS/GAUGE ReadingReading Voltage 3Ø-220/127 Uvwo Terminal Output Voltages Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø-200V/1Ø-115V Uvwo Terminal Output Voltages3Ø-440/254V Uvwo Terminal Output Voltages 1Ø-200/100V Uvwo Terminal Output VoltagesLubrication OIL INSPECTION/SETUPCircuit Breakers Fuel CheckRefueling Procedure Only use #2 diesel fuel when refuelingCoolant ANTIFREEZE/SUMMER COOLANT/ Water Cleaning the RadiatorAIR Cleaner FAN Belt Tension Operation in Freezing WeatherWiring BatteryBattery Cable Installation AlternatorStarting Generator START-UP ProcedureBefore Starting Engine’s exhaust contains harmful emissionsFrequency Meter Emergency Shutdown Procedure Generator SHUT-DOWN ProceduresNormal Shutdown Procedure Never stop the engine suddenly except in an emergencyAir Cleaner with Dust Indicator MaintenanceGeneral Inspection AIR Cleaner AIR Removal Fuel AdditionFuel Tank Inspection Replacing Oil Filter Radiator CleaningCheck OIL Level Flushing OUT Radiator and Replacing CoolantCoupler Type of hitch used on the trailer for towing Trailer MaintenanceTrailer Maintenance Hydraulic Surge Brakes Brake AdjustmentBrakes ActuatorSuspension TIRES/WHEELS/LUG NutsTire Wear/Inflation Lug Nut Torque Requirements Never use an pneumatic air gun to tighten wheel lug nutsTrailer Wiring Diagram Trailer/Towing Vehicle Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramTroubleshooting Generator Sample Parts List Explanation of Code in Remarks ColumnSuggested Spare Parts To 3 unitsGenerator Assy 0010310035 B31101002028051070003 0042510000Control BOX Assy FG3110WS02 3P 110A M12130008020601870431 0601870490Engine and Radiator Assy 0605000048 M19232000548970497081 0030010000Engine and Radiator Assy 0605515106 01500000180199900700 M9300000003Output Terminal Assy M9220100104 M1230700103M9220100204 0039310000Engine Operating Panel Assy 0602103092 89704441808944024980 2A# 0601810245Battery Assy M9310500014 0602220187627MFD M9103000304Muffler Assy 0016910025 M3330100902M1330100703 M1333001903Fuel Tank Assy M1363200104 M13630016020605505070 M9310500104Enclosure Assy M1423001902 M1413002902M1413400004 M1493106703Enclosure Assy Part Name QTY Rubber Seals Assy Seal Rubber Nameplate and Decals Assy M1550002003 M1550000204M1550001304 M1550002103Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help

CDA45SSIU3 specifications

The Multiquip CDA45SSIU3 is a versatile and powerful piece of equipment primarily designed for the construction and industrial sectors. As part of Multiquip's range of durable and reliable construction machinery, the CDA45SSIU3 is engineered to meet the demands of various tasks, including compacting soil, asphalt, and granular materials.

One of the standout features of the CDA45SSIU3 is its robust, high-performance engine. Powered by a reliable and efficient fuel system, the machine ensures optimal performance even under the heaviest loads. This not only improves productivity but also reduces fuel consumption, resulting in significant cost savings for contractors and operators.

The CDA45SSIU3 is equipped with advanced vibration technology, which provides exceptional compaction capabilities. Its dual-pump system delivers consistent performance, enabling operators to achieve the desired density in various soil types. This feature enhances the efficiency of the compaction process, making it ideal for preparing foundations, roadways, and other critical infrastructure.

Another notable characteristic of the CDA45SSIU3 is its user-friendly design. The machine comes with an intuitive control panel that allows operators to easily manage its functions. This ease of use reduces the learning curve for new operators, allowing them to quickly become proficient and maximizing productivity on job sites.

Durability is a key consideration in the design of the CDA45SSIU3. Constructed with high-quality materials, it withstands the rigors of demanding environments. The heavy-duty frame and components ensure longevity and consistent performance over time while minimizing maintenance requirements.

Additionally, the CDA45SSIU3 is designed with mobility in mind. Its compact dimensions and lightweight structure make it easy to transport between job sites. This portability ensures that operators can efficiently transition from one project to another without unnecessary delays.

Safety features are also a priority with the CDA45SSIU3. Equipped with safeguards that prevent accidental operation and enhance operator safety, the machine provides peace of mind while in use.

In summary, the Multiquip CDA45SSIU3 stands out as a powerful, reliable, and efficient solution for compaction tasks in construction and industrial applications. Its advanced engine, vibration technology, user-friendly controls, durable construction, and safety features make it an excellent choice for professionals seeking high-performance equipment. With the CDA45SSIU3, users can expect enhanced productivity, reduced operating costs, and reliable performance in various conditions.