Mosquito Magnet LIBERTY PLUS manual Safety Instructions, For your safety if you smell gas

Page 3

Safety Instructions

Please read and follow all safety instructions and warnings.

For your safety if you smell gas:

1 . Shut off the gas to your Liberty Plus.

2 . Extinguish any open flame.

3 . If odor continues, immediately call your gas supplier.

4 . Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

5 . The Liberty Plus is for outdoor use o n l y. If stored indoors detach and leave propane cylinder outdoors at all times.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.

Young children should be carefully supervised when they are in the area of the heater. Keep out of reach of children.

Clothing or other flammable materials should not be hung from the heater, or placed on or near the heater.

Note: Some or all of the following required safety instructions for propane powered devices may apply to your Liberty Plus.

Wa r n i n g : Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing the Liberty Plus.

C a u t i o n : The gas pressure regulator provided with this appliance must be used. This regulator is set for an outlet pressure of 28cm Water Column. The minimum inlet gas supply pressure is 28cm WC from regulator.

The gas supply must be turned off at the LP-Gas supply cylinder when this appliance is not in use.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.

1-1998 for US and with the CAN1-B149 for Canada.

To test for a gas leak, place soapy water around the regulator. If bubbles appear, there is a gas leak.

The hose assembly must be replaced prior to the appliance being put into operation if there is evidence of excessive abrasion or w e a r, or if the hose is damaged. The replacement hose assembly shall be that specified by the manufacturer.

The Liberty Plus is equipped with an internal hot surface ignition device. Failure to follow starting procedure will result in the trap not starting.

Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative that the control compartment, burners, and circulating air passageways of the heater be kept clean.

Adequate clearances of 50.6cm – 60.96cm around air openings into the combustion chamber, clearances from combustible material, provisions for accessibility and for combustion and ventilating air supply. Keep the Liberty Plus area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. The appliance is not to be used in locations where flammable vapor or explosive dust is likely to exist.

Do not obstruct the flow of combustion and ventilation air.

Keep the ventilating openings of the cylinder enclosure free and clear from debris.

Clean the Liberty Plus with a water damp cloth, if necessary.

A maximum of a 20 lb. LP-Gas cylinder shall be used without a base extension.

For accessories and additional info contact your local dealer/distributor.

3

Dealer contact info can be found at: www.mosquitomagnet.com/dealers

Image 3
Contents Page Contents For your safety if you smell gas Safety InstructionsCharging Adapter Net Principal Parts Self-Contained Liberty PlusParts Included Regulator Hose Support Pole Base SupportInstallation Assembly InstructionsMaintenance Troubleshooting Quick Clear ValveQuick Clear Va l v e Limited Warranty Limited Wa r r a n t yAT S O E V E R Page Codes de défaut des DEL Sommaire Instructions de sécuritéQuestions ou commentaires Fonctionnement du Mosquito MagnetAdaptateur de charge Filet Pièces principales Liberty Plus AutonomePièces incluses Tuyau de régulateur Perche de support Support de la baseInstructions de montage Installation Entretien Valve Quick-Clear DépannageValve Quick-Clear Garantie limitée Garantie limitéeE n t s Page Contenuto Istruzioni di sicurezza Dubbi o commentiModalità di funzionamento del Mosquito Magnet Parti in dotazione Parti principali Liberty Plus AutonomoIstruzioni di montaggio InstallazioneInstallazione Manutenzione Risoluzione dei problemi Valvola Quick ClearValvola Quick-Clear Garanzia limitata Garanzia limitataPage Funktionsweise des Mosquito Magnet InhaltSicherheitsvorkehrungen Fragen oder BemerkungenD e a d a p t e r T z Hauptkomponenten Aufbau Liberty PlusIm Lieferumfang enthaltene Teile G l e r s c h l a u c h Ä n d e r C k e lZusammenbauanleitung Wartung Quick-Clear-Ventil FehlersucheI c k C l e a r- Ve n t i l Beschränkte Garantie Beschränkte GarantieMail international@mosquitomagnet.com Téléphone Tel Mail international@mosquitomagnet.comTelefon Phone Mail international@mosquitomagnet.com North Kingstown, Rhode Island, USA

LIBERTY PLUS specifications

The Mosquito Magnet Liberty Plus is a highly effective tool designed to combat mosquito populations and enhance outdoor living experiences. Standing out in the realm of mosquito control, this innovative device employs advanced technologies to attract, capture, and ultimately eliminate these pesky insects.

One of the primary features of the Liberty Plus is its patented CO2 technology that mimics human breath. This technology releases a steady stream of carbon dioxide, which is a major attractant for mosquitoes. By producing a realistic carbon dioxide signature, the Mosquito Magnet effectively lures mosquitoes from a wide area, drawing them away from people and pets.

In addition to CO2, the Liberty Plus utilizes a unique attractant called Octenol. This natural compound further enhances its appeal to mosquitoes, making it more effective in varying environmental conditions. The combination of CO2 and Octenol enables the Liberty Plus to cover a significant radius, making it ideal for larger backyards and outdoor spaces.

The design of the Mosquito Magnet Liberty Plus is user-friendly and efficient. It features a durable construction built to withstand various weather conditions, ensuring long-term use throughout the mosquito season. The device operates on propane, which not only fuels the production of carbon dioxide but also facilitates the heat necessary to entice mosquitoes effectively.

Another significant aspect of the Liberty Plus is its innovative self-contained netting system that captures mosquitoes as they approach. Once trapped, the insects are unable to escape, leading to a significant reduction in their population over time. This trap also has an easy-to-use disposal system that allows users to maintain the device with minimal hassle.

For convenience, the Mosquito Magnet Liberty Plus is equipped with a digital control panel that monitors and manages operational settings. This smart feature allows users to customize the device's functionality according to their specific needs, ensuring optimal performance.

The exceptional performance of the Liberty Plus not only enhances comfort but also allows for more enjoyable outdoor experiences. By effectively targeting and reducing mosquito populations, it promotes safer gatherings and recreational activities in yards and gardens, creating a more inviting environment for family and friends.

In conclusion, the Mosquito Magnet Liberty Plus represents a powerful solution for combating mosquito issues. With its advanced CO2 technology, effective attractants, robust design, and user-friendly features, it is an essential addition for anyone looking to reclaim their outdoor spaces from these troublesome pests.