Minelab SD2100v2 instruction manual Set the Tune Control, Ground Balancing

Page 13

Instruction Manual

Page 3

5.2.5 Set the Tune Control

With the SD2100v2 switched On and the Threshold control and Tone control both set:

a)Hold the coil vertical to the ground and at waist height, then move the coil slowly through a half circle.

b)Listen for an increase in interference as you move the coil. When the interference is loudest, place the detector on the ground in this position, with the coil still vertical to the ground.

c)Adjust the Tune control to minimise the effect of the interference. The Tune control should be adjusted in small increments. In some cases it may not be possible to remove the interference completely, but the effect will be greatly reduced.

Once this control has been set for the location you are searching, it should not require readjustment unless conditions change or new interference is introduced, such as other detectors operating in the vicinity.

5.2.6 Ground Balancing

It is important to ground balance the SD2100v2 to the local conditions before commencing a search. For best results, ground balance to the ‘noisiest’ area of the ground you wish to search.

Assuming that the detector is operating with the Threshold and Tone both set, adjust the Balance controls using the following procedure:

a)Set the Search switch to the Balance 1 setting. Move the coil up and down between 20mm and 100mm above the ground, taking

about two seconds for each complete up and down movement. As the coil moves up and down, the volume and pitch of the threshold tone will change if the detector is not ground balanced.

Figure 5 - Ground Balancing

Image 13
Contents Minelab SD2100v2 Minelab Electronics Pty Limited Minelab SD2100v2 Table of ContentsIntroduction SD2100v2 List of Parts Part Item Number List of PartsUnpacking and Assembly SD2100v2 Battery Assembly Rear Panel Controls Control BoxFront Panel Controls Search SwitchQuick Start Instructions OperationDetector Sounds Operating InstructionsTurning on the SD2100v2 Set the Threshold ControlGround Balancing Set the Tune ControlMinelab SD2100v2 Battery Chargers BatteryCharging the Battery Auxiliary PartsVehicle Battery Charger Searching Detecting TechniquesProspecting Tips Identifying Target Signals Hints for Maximum Gold RecoveryPinpointing Pinpointing ProcedureDigging the Target Digging Deep Targets Salty EnvironmentsMaintenance Troubleshooting Specification Warranty Search Coils AccessoriesCorporate Clothing BatteriesPage Minelab SD2100v2 Page Minelab SD2100v2 Minelab Service Repair Form