get into it!
Safety guard of suction fitting must remain in place.
installation instructions
SUCTION GUARDS
The suction guard(s) in the footwell of your spa is an opening through which the jet pump draws water. Suction fittings are equipped with a safety guard. Suction through the fittings can be strong. The safety guard(s) must remain in place and undamaged. A fitting with a damaged guard(s) can be dangerous, especially to small children or people with long hair. Should any part of the body become drawn to a fitting, turn the jet pump off immediately. Long hair should be restrained in a bathing cap, never allow it to float freely in the spa. Replace any missing or damaged suction guard(s).
NOTE: It is normal for the flow rates of the suction fittings to vary from strong to barely noticeable.
ELECTRICAL REQUIREMENTS
It is the responsibility of the spa owner to ensure that all electrical connections are made in accor- dance with all electrical codes in effect at the time of installation.
120 Volt:
120V units must only be connected to a properly grounded, grounding type 15 amp dedicated receptacle. 120V equipment is designed to operate on 60Hz alternating current only at a voltage of 120, 12.5 amp. maximum load. Only use the cord provided with the spa, do not use an extension cord.
To Convert 120V to 240V: All connections must be made by a licensed electrician.
1.Disconnect power by unplugging from receptacle and remove cord from terminal block.
2.Remove white wire connected to J11 and J32 completely and discard.
3.Install 240V power line as indicated on page 14.
4.Set dip switch 10 to off position.
5.For units for use in other than
13