Keys Fitness BS-9101 owner manual Troubleshooting Guide, Control panel troubles and reasons

Page 16

Troubleshooting Guide

1.Press LIGHT on the control panel, but reading lamp does not on. Solution: 1) Unplug the MAIN POWER

2)Before you check the light, please feel if the light cover is hot, YOU can check it until it cools down.

3)Remove the TOP COVER of the sauna room.

4)Screw off the cooper nuts on lamp cover.

5)Remove the lamp holder.

6)Screw off the bulb gently.

7)Replace a new bulb with same voltage and wattage if the bulb is bad, and screw down gently.

8)Put on the TOP COVER and fasten the clamps.

2.When sauna is working, but some emitters are not heating up.

Solution: 1) Unplug the MAIN POWER.

2)Remove the top cover

3)Push the reset switch located next to the power cord on the back of the controlbox.

4)If the emitters are still not heating, call the distributors customer service department for further instructions.

Please ask the distributor's technician to repair when you meet with the following problems. DO not Repair the sauna unit by yourself.

3.Emitter becomes red when power on. This is emitter problem, do not continue heating, you should replace the emitter.

4.Emitter is broken or damaged. DO not continue to operate, and replace a new emitter.

5.CONTROL BOX has some abnormal phenomenon: such as, so high temperature; bad smell or make some sound; please power off immediately. Contact the distributor’s technician for checking.

6.Power cord or other cables are damaged or disconnection. do not use it again. Replace a power cord and connector etc. components.

Control panel troubles and reasons:

7. Control panel: No display.

Possible reasons: 1) The electricity power is not plugged well or lose contact, and it is not powered.

2)The CTRL connector on the CONTROL BOX is not plugged or lose contact.

3)CTRL cable is disconnected.

4)CONTROL BOX is damaged.

8.Control panel with display, but no function when you press on it.

Possible reasons: 1) Signal cable is disconnected.

2)Relevant plugs are not connecting or lost contact.

9.Emitter is working, inside sauna temperature is rising, but the temperature display does not change. Possible reasons: 1) Temperature sensor is damaged.

2)Temperature sensor down-lead is disconnected.

3)Temperature sensor down-lead connector is not connected or lose contact.

Note: You should keep the serial number for product warranty, (which is shown on the sauna Front Panel and outside package), and please give this information to your distributor for timely and efficiently after sale service.

Image 16
Contents 1-2PERSON SAUNA Enjoy Health And Beauty In Your LifeBS-9101 CONNECTIONREV.A exposure to infrareds outside of overheating MANUAL INDEX Product IntroductionPARTS DESCRIPTION 1Handle 2Safety glass door 3Ventilation gridA.FRONT PANEL SEE FIGURE B.PRODUCT INSIDE SEE FIGUREInstallation Instructions 2INSTALLATION ORDERFRONT PANEL RIGHT PANEL1Choose a good location to install the sauna room 3 Install the front panel4 Install the LEFT/RIGHT PANEL 2 Place the BOTTOM PANEL6 BUCKLE CONNECTIONS 5 Put on the BACK PANELFigure Figure 8 Place the TOP PANEL 9 CONTROL BOX10 COMPONENT MARKINGS MARKINGCOMPONENT CONNECTION 11 Connect all the plugs on the TOP PANEL12 Temperature sensor 14OPTIONALMP3 Shelf13 Put on the TOP COVER 15 Preparation SAUNA OPERATIONCONTROL PANEL FUNCTION 4. Switch between 0F and 0C 7. Inside reading lamp switch5. Set up the heating temperature 6. Start emitting or stop emittingTips for Using Your Sauna Safety InstructionsSafeguards for Your Sauna Troubleshooting Guide Control panel troubles and reasonsOne Year -Wood,Electronics, Heating Elements Warranty90 Days -Labor arrangements for payment