Jacuzzi SteamPro manual Troubleshooting, Symptoms Probable Causes Action to be Taken

Page 18

TROUBLESHOOTING

There are no user serviceable parts in the Generator. All repair should be performed by a qualified service person. For additional assistance or the factory authorized service person nearest you call the Service Department at 1-800- 363-0251. The Trouble Shooting Guide below is meant as a general aid only. Follow ACTION TO BE TAKEN in order until the problem is resolved.Where replacements or repairs are indicated, see the appropriate paragraph of SERVICE SECTION.

SYMPTOMS

PROBABLE CAUSES

ACTION TO BE TAKEN

Control won't

Improper power supplied (no

1. a. Make sure circuit breaker is "ON".

turn "ON"

power).

 

b. Using a voltmeter, check the voltage across the two fuses on the "PCA"

(Control light

Control improperly conntected.

 

printed circuit assembly. Voltage should be 208V / 240V.

off).

"PCA" printed circuit assembly

 

c. Check fuses on the PCA. If fuse(s) are blown, replace with Buss#

 

is faulty.

 

MDL 15/100 or equivalent fuse. If the fuse blows again - call

 

Control cable is faulty.

 

Service Department.

 

Contol is faulty.

2.

Check control(s) installed per Section 6-5.

 

 

3.

Replace PCA printed circuit assembly - call Service Department.

 

 

4. Replace control cable - call Service Department.

 

 

5.

Replace the control - call Service Department.

Control "OFF".

Water solenoid valve is stuck

1. Turn off power to the generator. If the water stops, go to step 3.

(Control light off)

open.

2. a. Remove the water solenoid valve, dissassemble, clean,

Water won'tshut

"PCA" printed circuit assembly

 

re-assemble, and check for proper operation.

off and runs out

is faulty.

 

b. Replace valve - call Service Department.

of the steam

 

3.

Replace the "PCA" printed circuit assembly - call Service Department.

head.

 

 

 

Control "ON".

"PCA" printed circuit assembly

1. Check that the blue wire is properly attached to the water level probe.

(Control light

is faulty.

2.

Check that the generator is properly grounded.

on) Water won't

Connection between the blue

3.

Check the green ground wires to the "PCA" printed circuit assembly.

shut off and runs

wire and the water level probe

4. Replace the "PCA" printed circuit assembly - Service Department.

out of the steam

is faulty.

 

 

head.

Unit improperly grounded.

 

 

Control "ON"

No water supplied (turned off?)

1. Check for proper water supply (Supply valve "on"). Check for closed drain valve.

(Control light

Plugged water solenoid valve.

2.

Remove the blue wire from the level probe. If the unit fills, clean or replace the

on), Tank

Water solenoid valve is faulty.

 

level probe.

drained.

"PCA" printed circuit assembly

3.

Reconnect the shortest wire to the level probe. At the water valve solenoid, slide

Unit won'tfill.

is faulty.

 

back the blue connector enough to get the voltmeter probes on the solenoid

 

Level probe is faulty.

 

terminals. Measure the voltage across the solenoid terminals. If it is not 208V /,

 

 

 

240V replace the printed circuit assembly. If 208V / 240V is found proceed

 

 

 

with steps 4 & 5.

 

 

4. Remove water solenoid valve; disassemble, clean, reassemble, and check for

 

 

 

proper operation.

 

 

5.

Replace the water solenoid valve - call Service Department.

(Auto Drain Only

"PCA" printed circuit assembly

1. a. Make sure 25 minutes has elasped.

Installations)

is faulty.

 

b. Disconnect drain valve wires. If drain valve opens replace "PCA".

Control turned

Drain valve may be clogged

2. a. Disassemble drain valve and clean.

"OFF" tank

with calcium.

 

b. Clean tank using deliming solution

does not drain

 

 

 

after 25 minutes

 

 

 

and motorized

 

 

 

drain valve stays closed.

16

Image 18
Contents Steampro TM Important Safety Information Contents Installation How to Select Generator SizeElectrical Requirements Locating the Steam Generator Room Construction and Ventilation ImportantPlumbing Instructions and Cautionary Notes on Installation Plumbing Diagram Steam Head Installation for Various Wall Surfaces KW Steam Generator with Two Steam Heads Automatic Drain Valve Installation Optional Important Note About Tank Drain SelectionOutlet must point as shown Steam Controls-Available Installation Methods Control cable rough-in Install generator control R30iSteam Control by 30 Minute LOW Voltage ON/OFF Control Control cable at the generatorElectrical Rough-in General Instructions for Temperature Control ModelsTemperature Sensor Rough-in Electrical finishInstall Generator Control Install Temperature SensorOptional Secondary Generator Control Temperature Adjustment Minute Temperature ControlOperation of Your 30 Minute Temperature Control OperationDigital Time and Temperature Control Operation of Your Digital Time and Temperature ControlDescription of SteamPro Steam Generator ServiceMaintenance of SteamPro Generators Repair of SteamPro GeneratorsTroubleshooting Symptoms Probable Causes Action to be TakenSymptoms Probable Causes OFFWiring Diagram Jacuzzi Whirlpool BathJacuzzi Whirlpool Bath National Headquarters Amerec Name of Purchaser Address City Zip Phone

SteamPro specifications

The Jacuzzi SteamPro is an innovative steam shower system designed to elevate your home spa experience, offering a blend of relaxation and wellness. Known for its sleek design and advanced technology, the SteamPro is not just a steam generator; it embodies the essence of luxury and comfort.

One of the standout features of the SteamPro is its ability to produce high-quality steam quickly and efficiently. The advanced steam generator utilizes a patented technology that ensures rapid heating, allowing users to enjoy soothing steam in less time. This efficiency is complemented by customizable steam settings, which enable you to adjust the intensity and duration of your steam sessions to suit your personal preferences.

The SteamPro also incorporates a user-friendly control panel, featuring a digital display that allows for easy navigation and access to various functions. This interface gives users the ability to program personalized steam sessions, including pre-set temperature levels and aromatherapy options. The inclusion of essential oil dispensers enhances the experience, filling your space with calming scents that promote relaxation and well-being.

In terms of technology, the SteamPro is equipped with an advanced water softening system that minimizes mineral buildup, ensuring longevity and optimal performance. This system not only protects the unit but also contributes to cleaner steam, enhancing the overall shower experience. The design also allows for efficient drainage, preventing water from pooling and maintaining a clean environment.

Safety is a top priority with the SteamPro, which incorporates features such as automatic shut-off functions to prevent overheating and overpressure. The steam generator is constructed from high-quality materials that resist corrosion and wear, ensuring durability and reliability over time.

The SteamPro’s compact design makes it an ideal choice for various bathroom layouts, easily integrating with both new and existing setups. Its stylish aesthetics add a modern touch to any space, making it not just a functional piece of equipment, but also a stylish addition to your home.

In summary, the Jacuzzi SteamPro is a pinnacle of steam shower technology that combines efficiency, safety, and luxury. With customizable features, advanced materials, and user-friendly design, it represents a significant advancement in home wellness solutions, allowing users to transform their daily routine into a spa-like retreat. Whether it’s for relaxation or therapeutic benefits, the SteamPro provides an unparalleled steam shower experience.