INSTALLATION

DANGER RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).

CAUTION TEST THE GROUND FAULT CIRCUIT INTERRUPTER PROTECTING THIS APPLIANCE PERIODICALLY IN ACCORDANCE WITH MANUFACTURER’S INSTRUCTIONS.

WARNING USE THIS UNIT ONLY FOR ITS INTENDED USE AS DESCRIBED IN THIS MANUAL. DO NOT USE ATTACHMENTS NOT RECOMMENDED BY THE MANUFACTURERS. WARNINGTOAVOIDINJURY,EXERCISECAUTIONWHENENTERINGOREXITINGTHEHYDROMASSAGEBATHTUB. WARNING KEEP BODY AND HAIR A MINIMUM OF 6" (15,2 cm) AWAY FROM SUCTION FITTING AT ALL TIMES WHEN THE HYDROMASSAGE SYSTEM IS OPERATING. HAIR LONGER THAN SHOULDER LENGTH SHOULD BE SECURED CLOSE TO THE HEAD.

WARNING RISK OF ELECTRICAL SHOCK; DO NOT PERMIT ELECTRICAL APPLIANCES (SUCH AS HAIR DRYER, LAMP, TELEPHONE, RADIO OR TELEVISION) WITHIN 60" (1.5 m) OF THIS HYDROMASSAGE BATHTUB. WARNING RISK OF ACCIDENTAL INJURY OR DROWNING; DO NOT USE DRUGS OR ALCOHOL BEFORE OR DURING THE USE OF HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER TO AVOID UNCONSCIOUSNESS AND POSSIBLE DROWNING.

WARNING RISK OF FETAL INJURY; PREGNANT OR POSSIBLY PREGNANT WOMEN SHOULD CONSULT A PHYSICIAN BEFORE USING A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER. WARNING RISK OF HYPERTHERMIA AND POSSIBLE DROWNING; DO NOT USE A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER IMMEDIATELY FOLLOWING STRENUOUS EXERCISE.

WARNING RISK OF HYPERTHERMIA AND POSSIBLE DROWNING; WATER TEMPERATURE IN EXCESS OF 104°F (40°C) MAY BE INJURIOUS TO YOUR HEALTH. CHECK AND ADJUST WATER TEMPERATURE BEFORE USE.

WARNING RISK OF HYPERTHERMIA; PEOPLE USING MEDICATIONS AND/OR HAVING AN ADVERSE MEDICAL HISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER.

WARNING THE USE OF ALCOHOL, DRUGS OR MEDICATION CAN GREATLY INCREASE THE RISK OF FATAL HYPERTHERMIA.

FOR BUILT-IN AND DROP-IN UNITS, INSTALL TO PERMIT ACCESS FOR SERVICING.

THIS UNIT SHOULD BE ELECTRICALLY GROUNDED AND INSTALLED BY A LICENSED CONTRACTOR, ELECTRICIAN, AND PLUMBER.

BUILDING MATERIALS AND WIRING SHOULD BE ROUTED AWAY FROM THE MOTOR/PUMP OR BLOWER OR OTHER HEAT PRODUCING COMPONENTS OF THIS UNIT.

A PRESSURE WIRE CONNECTOR IS PROVIDED ON THE EXTERIOR OF THE MOTOR/PUMP AND HEATER TO PERMIT CONNECTION OF AN NO. 8 AWG (8.4 MM) SOLID COPPER BONDING CONDUC- TOR BETWEEN THIS UNIT AND ALL OTHER ELECTRIC EQUIPMENT AND EXPOSED METAL IN THE VICINITY, AS NEEDED TO COMPLY WITH LOCAL REQUIREMENTS.

PRECAUTIONS

Do not operate the hydromassage system unless the bath is filled with water to at least 1" to 2" (25,4 mm to 50,8 mm) above the highest jet.

Do not immerse the control panel by overfilling the bath.

Do not use oil-based bath additives in your hydromassage bath.

When cleaning your bath, do not use abrasive substances which will damage the bath's surface.

To prevent discoloration of the acrylic finish, do not fill the bath with water in excess of 140°F (60°C).

Do not use household cleansers on any of the wood surfaces if equipped.

NOTE: This is a professional grade product. A knowledge of construction techniques, plumbing and electri- cal installation according to codes are required for proper installation and user satisfaction. We recommend that a licensed contractor perform the installation of all Jacuzzi Whirlpool Bath products. Our warranty does not cover improper installation related problems.

3

ENGLISH

Jacuzzi Whirlpool Bath DE99000A 3/06

Image 3
Contents Fuzion Bath Series English Installation Contents Specifications InstructionsRectangular With Teak Specifications RectangularSpecifications Specifications CornerCorner Baths 35-3/8 ROUGHING-IN Reference RectangularLeft Hand Motor ROUGHING-IN ReferenceFuzion 7260 Dual Motor with Wood Frame Corner Cutout ROUGHING-IN Reference CornerFraming and Support DROP-IN TUB Installation InstructionsUnit Protection Undermount TUB Installation InstructionsUndermount Installation Options InstallationCounter Adhering Counter to BathControl Panel Installation Installation InstructionsFor 230 VAC units Do not switch power cords and Gfci circuitsElectrical Connections For 120 VAC unitsWater Supply Faucet InstallationOverflow Fitting Installation PlumbingFinishes Water LevelControlling Whirlpool Action Operating Instructions contd Operation Operating Instructions contd RapidHeatTMMaintenance Instructions Suction Cover/Strainer Maintenance Chromotherapy LightingIllumatherapyTM Lighting Problem Probable Causes Remedy General Whirlpool Bath Troubleshooting GuideService Support 800 Authorized ServiceJacuzzi Whirlpool Bath Responsibilities of Others Registration Warranty Card