6 INSPECTION AND TROUBLESHOOTING
6.2Troubleshooting
If problems are not remedied, contact technical support at
SYMPTOMS | FAULTS | SOLUTION |
Hydromassage System |
|
|
|
|
|
System will not start | No electrical power to tub | Check and reset breaker |
|
|
|
| Switch air hose disconnected | Reconnect hose to switch and controller |
|
|
|
System is ineffective | Water deposits in whirlpool jets | Disassemble and clean whirlpool jets |
|
|
|
System is noisy | Whirlpool jets are turned on | Turn off the whirlpool jets. Add water to the tub to completely cover the jet |
| without water completely | assemblies and test the whirlpool function again. |
| covering the jet assemblies |
|
|
|
|
Tub Operation |
|
|
|
|
|
No water flow | Water supply turned off | Turn on water supply |
|
|
|
Restricted water flow | Water temperature control valve | Inspect and clean the water temperature control valve. Refer to the Moen service |
|
| manual at www.moen.com. Search for Model 3371 ExactTemp Temperature Control |
|
| Valve, Service Manual Number 153768. |
|
|
|
Invacare® TheraPure™ Recessed Whirlpool Tubs | 32 | Part No. 1167458 |