Invacare IH6300ADH manual Heavy Duty Cleaning Procedure

Page 27

SECTION 5—MAINTENANCE

Heavy Duty Cleaning Procedure

WARNING

DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner’s manuals, service manuals or instruction sheets supplied with this product or optional equipment. If you are unable to understand the warnings, cautions or instructions, contact a healthcare professional, dealer or technical personnel before attempting to use this equipment - otherwise, injury or damage may occur.

The disinfectant dispensing system has been factory tested and calibrated for use with Invacare disinfectant. The use of any disinfectant with a dilution ratio (½ oz per gallon) or viscosity level different than that of Invacare disinfectant will result in an improper mixture of disinfectant and water. This may cause your system to be improperly disinfected - or in some instances, not disinfected at all. If using any disinfectant with a dilution ratio or viscosity level different than that of Invacare disinfectant or if switching from one type of disinfectant to another type, the disinfectant flowmeter must be calibrated before performing this procedure. Refer to the tub owner’s manual or to the calibration instruction sheet, part number 1154272, for the calibration procedure.

ALWAYS wear rubber gloves, an apron and face shield protection during disinfecting, cleaning and rinsing procedures. In case of eye or skin contact, follow procedures on disinfectant container.

CAUTION

NEVER use abrasive cleaners like scouring powder or liquid cleaners containing pumice stone. The use of these types of cleaners will make the gel-coat finish of your tub scratched and dull. NEVER use cleaners containing iodine, bromine, Betadine or methylene blue. The use of these types of cleaners will cause the tub to stain. Never use cleaners containing bleach. Use of these types of cleaners will dry out the rubber seals and gaskets and the tub will not function properly.

Before starting the whirlpool pump, the water level must be completely above the whirlpool jets. Otherwise damage to the motor/pump will result.

In addition to disinfecting your tub after every use, you will need to perform this procedure approximately once every 80‐150 baths.

1.Clean the entire surface of the tub to remove visible tissue residue and fluid.

2.Rinse the inside surface of the tub with the shower/massage wand on the spray setting.

3.Rotate the water temperature valve to adjust the water temperature to 105o F.

NOTE: This will maximize the cleaning solutionʹs ability to clean and disinfect the system.

4.Close the drain.

5.Make sure the whirlpool jets are open.

NOTE: The required amount of water to cover the whirlpool jets is 50 gallons. 6. Fill the tub above the whirlpool jets.

NOTE: The required amount of Invacare Heavy Duty Cleaner is 200 ounces.

7.Add the Invacare Heavy Duty Cleaner to the water in the tub.

8.Spray pre‐mixed Invacare Heavy Duty Cleaner on the remaining surfaces.

9.Press the whirlpool on/off button to turn on the whirlpool pump and let the pump run for 60 seconds.

10.Turn off the pump and allow the heavy duty cleaner/water solution to remain in the tub for 10 minutes.

11.During this ten‐minute waiting time, take a long handled brush and thoroughly scrub all interior surfaces of the tub.

12.Open the drain to allow the heavy duty/water solution to drain from the tub.

13.Use the shower/massage wand on the pulse setting and direct the spray into both whirlpool jets to back flush until the water discharging from the whirlpool inlet is clear.

14.Rinse the tub thoroughly with the shower wand on the spray setting.

15.Check the tub for damage and to ensure all surfaces of the tub are clean and that no visible residuals remain. If residuals are found, repeat STEPS 13 and 14.

Part No 1096926

27

Supine Bath Tub

Image 27
Contents Supine Bath Tub Accessories Warning Table of Contents Troubleshooting Limited Warranty Special Notes PAR9992 Label LocationTypical Product Parameters Fixed Height Adjustable HeightFeatures Plumbing InstallationGeneral Guidelines ElectricalElectrical Shock Hazard Maintenance and InspectionDisinfecting OperationGeneral Guidelines Disinfecting the TUB Disinfecting the Tub Using the Closed Loop SystemOperation OverviewPreparing the Tub for Use Operating the Tub Using Water Temperature SettingUsing Hydromassage Operating Shower/Massage WandFilling the Tub Adjusting Tub Height Model IH6300ADH only Raising the Supine TubLowering the Supine Tub Preparing the Work Area InstallationSecuring the Tub Securing the TubElectrical Hook-up Install the electrical hook‐ups per FigureElectrical Hook-up Electrical Installation Electrical InstallationPlumbing Hook-Up Install the plumbing hook‐ups per FigurePlumbing Installation Plumbing Installation and Schematic Before Each Use MaintenanceParts Information Safety Inspection Checklists InitiallyEvery Six Months Maintenance for IH6300ADH Adjustable Height only Glide PadsRemoving Soap Film and Hard Water Deposits Removing Calcium Deposits, Scale and Lime Build-upHeavy Duty Cleaning Procedure Calibrating the Disinfectant Flowmeter Calibrating the Disinfectant Flowmeter Maintenance Record Symptoms Faults Solution TroubleshootingUSA Limited Warranty

IH6300, IH6300ADH specifications

The Invacare IH6300ADH and IH6300 are advanced power wheelchairs designed to enhance mobility and independence for individuals with limited mobility. Featuring cutting-edge technology, these chairs are engineered to provide a safe, comfortable, and reliable mode of transportation for users.

One of the standout features of the Invacare IH6300 series is its robust and durable design. Built with a sturdy steel frame, these chairs can support a higher weight capacity, ensuring that they can accommodate a wide range of users. The ergonomic seating system provides optimal support and comfort during use, with adjustable seat depth and height options that cater to individual needs.

The IH6300ADH model takes comfort a step further with its enhanced cushioning and sophisticated suspension system, which absorbs shocks from uneven surfaces, allowing for a smoother ride. This is particularly beneficial for users who may travel over varied terrains or who may spend extended periods in their wheelchair.

Power and maneuverability are also key aspects of the Invacare IH6300 series. Both models come equipped with powerful motors that allow for swift movement and the ability to navigate inclines and tight spaces with ease. The intuitive joystick control enables users to operate the wheelchair effortlessly, offering precision in direction and speed.

Safety is paramount in the design of the IH6300 series. These wheelchairs feature intelligent braking systems that halt the chair when the joystick is released, preventing unintended movement. Additionally, the chairs are designed with anti-tip technology to enhance stability and prevent accidental falls.

The Invacare IH6300 series also boasts impressive battery life and efficiency, providing users with the freedom to travel longer distances without frequent recharging. The batteries are easily accessible for maintenance or replacement, ensuring ongoing reliability.

In summary, the Invacare IH6300ADH and IH6300 power wheelchairs stand out due to their exceptional build quality, user-friendly controls, and comprehensive safety features. They are ideal for individuals seeking mobility solutions that prioritize comfort, durability, and independence. With a range of options tailored to meet diverse user needs, the Invacare IH6300 series continues to be a leading choice in the realm of powered mobility devices.