11.Close all jets by pushing the center of each jet in or turning the center of the jet clockwise.

12.Close the whirlpool inlet by pulling the inlet plug out.

13.Turn the disinfectant valve to the on position.

NOTE: Liquid will be heard filling the interior plumbing of the tub.

14.Note the position of the floating ball in the flow meter.

15.Adjust the injector by performing one of the following:

Bottom of Floating Ball Reads Greater Than 35 ‐ Less disinfectant needs to be added to the mixture. Loosen the screw on the injector to draw less disinfectant into the solution.

Bottom of Floating Ball Reads Less Than 35 ‐ More disinfectant needs to be added to the mixture. Tighten the screw on the injector to draw more disinfectant into the solution.

16.When the bottom of the floating ball is near 35, turn the black adjustment knob on the flow meter until the bottom of the floating ball is at 35.

17.Place the bucket/pail under the burp fitting to collect the disinfectant. Use a funnel if necessary.

18.Note the number of ounces in the graduated plastic bottle.

19.Let the bucket/pail fill to one gallon.

20.Turn the disinfectant valve to the off position.

21.Remove the disinfectant draw tube from the plastic bottle.

22.Examine the amount of disinfectant remaining in the plastic bottle.

23.Subtract the amount of disinfectant remaining from the amount noted in STEP 18.

24.Perform one of the following:

Approximately ½‐ounce of disinfectant has been used ‐ Proceed to STEP 23.

Much more or much less than ½‐ounce of disinfectant has been used ‐ repeat STEPS 1‐18.

25.Position the disinfectant draw tube into the disinfectant solution.

26.Disinfect the tub. Refer to Disinfecting the Tub Using the Closed Loop System on page 23.

Side Entry Whirlpool Tub

32

Part No 1118387

Image 32
Contents Side Entry Whirlpool Tub Accessories Warning Table of Contents Limited Warranty Maintenance Special NotesLabel Location Cabinet Door 3600XLTypical Product Parameters ModelFeatures Models 3600 and 3600XLModel General Guidelines Important Safety InstructionsInstallation Electrical PlumbingMaintenance and Inspection DisinfectingGeneral Guidelines Parts Installation About InstallationParts Information Preparing the Work AreaPreparing the Work Area Securing Tub Securing TubElectrical Installation Electrical and Plumbing Hook-up Locations on the TubParts and Installation Electrical Installation Plumbing Installation Post Installation Checklist Plumbing InstallationOperating Instructions OverviewDisinfecting the Tub Using the Closed Loop System Closing the Tub Door Opening/Closing the Tub DoorOpening the Tub Door Water Temperature Setting Tub OperationOperating Shower/Massage Wand Filling TubHydromassage Filling TubSafety INSPECTION/ Troubleshooting Safety Inspection Checklists Cleaning Cleaning the Door Seal Gasket Cleaning Your Tub Removing Soap Film and Hard Water DepositsHeavy Duty Cleaning Procedure Required OZCalibrating the Disinfectant Flow Meter Safety INSPECTION/TROUBLESHOOTING Troubleshooting Symptoms Faults SolutionMaintenance Record Side Entry Whirlpool Tub Limited Warranty USA