Set up Precautions (cont.)

9.Improper connections to a building electrical system can allow electrical current from the generator to backfeed into the utility lines.

Such backfeed may electrocute utility company workers or others who contact the lines during a power outage, and the generator may explode, burn, or cause fires when utility power is restored. Consult the utility company and a qualified electrician if intending to use the generator for back up power.

10.Do not operate the Generator before grounding. The Generator must be earth-grounded

in accordance with all relevant electrical codes and standards before operation.

Safety

Operating Precautions

1.Carbon Monoxide Hazard Using a generator indoors CAN KILL

YOU IN MINUTES.

Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.

NEVER use inside a home or garage, EVEN IF doors and windows are open.

Only use OUTSIDE and far away from windows, doors, and vents.

2.Never use a generator indoors, including in garages, basements, crawlspaces and sheds. Opening doors and windows or using fans will NOT prevent carbon monoxide build up in the home.

3.When using generators, keep them outdoors and far away from open doors, windows, and vents to avoid toxic levels of carbon monoxide from building up indoors.

4.If you start to feel sick, dizzy, or weak while using a generator, get to fresh air right away. The carbon monoxide from generators can quickly lead to full incapacitation and death.

5.Keep children away from the equipment, especially while it is operating.

6.Keep all spectators at least six feet from the Engine during operation.

7.Fire Hazard! Do not fill gas tank while engine is running. Do not operate if gasoline has been spilled. Clean spilled gasoline before starting engine.

Do not operate near pilot light or open flame.

8.Do not touch engine during use. Let engine cool down after use.

9.Never store fuel or other flammable materials near the engine.

10.If the plugged in product operates abnormally or unusually slow, immediately stop using the generator as a power source. Always read and adhere to the instruction manual of the product to be powered, to make sure that it can be safely and efficiently powered by a portable generator.

11.Before connecting an appliance or power cord to the generator: Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock.

12.Do not exceed the maximum power rating of the generator. Make sure that the total electrical rating of the all of the tools or appliances plugged into the generator at the same time does not exceed that of the generator. Check that the startup surge will not be beyond the limit of the Generator. Power levels between rated and maximum

may be used for no more than 30 minutes.

13.Avoid substantially overloading which will trip the circuit breaker. Exceeding the time limit for maximum power operation or slightly overloading the generator may not switch the circuit breaker or circuit protector OFF, but will shorten the service life of the generator.

14.Do not attempt to connect or disconnect load connections while standing in water, or on wet or soggy ground.

15.Do not touch electrically energized parts of the Generator and interconnecting cables or conductors with any part of the body, or with any non-insulated conductive object.

Setup

Operation

Maintenance

Item 68526 / 68529

For Pump technical questions, please call 1-800-444-3353.

Page 3

For Engine technical questions, please call 1-800-520-0882.

Image 3
Contents Watt Portable Table of Contents Important Safety InstructionsOperating Precautions Setup Operation MaintenanceCarbon Monoxide Hazard Using a generator indoors can Kill Safety Setup Operation Maintenance Refueling Service PrecautionsComponents and Controls SpecificationsSafety Setup Operation MaintenanceOFF Altitude Range Kit Part Number GroundingHigh Altitude Operation PerationGenerator Pre-Start Checks Checking and Filling Engine OilChecking and Filling Fuel Using the Generator Starting the Engine Safety Setup Operation Connecting Electrical LoadsEquipment ExampleTo Calculate Wattage Stopping the Engine Under Normal Conditions Stopping the Engine in an EmergencyHr. of use Cleaning, Maintenance, and LubricationAintenance Air Filter Element MaintenanceChecking and Filling Fuel Engine Oil ChangeStorage Spark Plug MaintenanceTroubleshooting Do not use gasoline with more than10% ethanol E15, E20, E85, etc Use Engine will not start Compression Related section SetupPlease Read the Following Carefully Parts ListFollowing parts are only on Item 68526 EPA/CARB version Accessories not included provided on requestEPA/Carb 160 AintenanceM PerationO EtupS AfetySOwner’s Warranty Responsibilities For Both Item Numbers Manufacturer’s Warranty CoverageMission Oaks Blvd. PO Box 6009 Camarillo, CA 93011 800

68526 specifications

Harbor Freight Tools is renowned for providing a range of high-quality and affordable tools suitable for both professionals and DIY enthusiasts. One of their popular products is the Harbor Freight Tools 68526, a versatile and powerful portable generator with features that make it an essential addition to any toolkit.

The Harbor Freight Tools 68526 is a 2000 Watt inverter generator that offers clean and stable power, making it perfect for powering sensitive electronics such as laptops, smartphones, and medical devices. Its advanced inverter technology ensures that the power output is similar to that of standard household outlets, reducing the risk of damage to your valuable equipment.

One of the standout characteristics of this generator is its lightweight and compact design. Weighing only around 48 pounds, it is easy to transport and maneuver, making it ideal for camping trips, outdoor events, or emergency home backup. The built-in carrying handle adds to the convenience, allowing users to easily move the generator from one location to another.

The 68526 model features a quiet operation, thanks to its efficient engine design. With a noise level of just 58 dB, it operates quietly, making it suitable for use at night or in noise-sensitive environments. This feature is particularly appreciated at campsites or outdoor gatherings where maintaining a peaceful atmosphere is important.

Equipped with a 1-gallon fuel tank, the 68526 provides a runtime of up to 6 hours at 50% load on a single tank of gas. This extended runtime means that users can rely on the generator for longer periods without the need for frequent refueling, which is a significant advantage during power outages and outdoor activities.

In terms of connectivity, the Harbor Freight Tools 68526 comes with two 120V AC outlets and one 12V DC outlet, allowing users to charge multiple devices simultaneously. Additionally, it includes a USB port which adds versatility, enabling the charging of various electronic devices directly.

To ensure safety and reliability, this generator features an automatic low-oil shutdown mechanism that protects the engine from damage. Users can operate it with peace of mind, knowing that the unit will shut down if the oil level becomes too low.

In summary, the Harbor Freight Tools 68526 is a powerful, portable, and efficient inverter generator that combines advanced technology, user-friendly features, and dependable performance, making it a valuable tool for anyone in need of reliable power on the go. Whether for home use or outdoor adventures, this generator proves to be a dependable companion.