Guardian Technologies 005284, 005281, 005282, 005283, 005280, 005243 Battery Cable Connections

Page 13

Section 1 — General Information

Air-cooled Generators

Figure 1.10 – Battery Cable Connections

NOTE:

In areas where temperatures regularly fall below 10° F (-12° C) it is recommended that a pad type battery heater be installed to aid in cold climate starting (see Specifications).

NOTE:

The generator is equipped with a battery trickle charger that is active when the unit is set up for automatic operation. With the battery installed and utility power source voltage available to the transfer switch, the battery receives a trickle charge while the engine is not running, to prevent self-discharge. The trickle charger is designed to help extend the life of the battery by maintain- ing the battery when the unit is not running. The trickle charge feature cannot be used to recharge a discharged battery.

1.13 THE BATTERY

DANGER

Do not dispose of the battery in a fire. The battery is capable of exploding.

A battery presents a risk of electrical shock

and high short circuit current. The following pre- cautions are to be observed when working on batteries:

Remove the 15A fuse from the generator control panel.

Remove watches, rings or other metal objects;

Use tools with insulated handles;

Wear rubber gloves and boots;

Do not lay tools or metal parts on top of the battery; and

Disconnect charging source prior to connecting or disconnecting battery terminals.

Do not open or mutilate the battery. Released electrolyte has been known to be harmful to the skin and eyes, and to be toxic.

The electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes. It is electrically conductive and corrosive.

The following procedures are to be observed:

Wear full eye protection and protective clothing;

Where electrolyte contacts the skin, wash it off immediately with water;

Where electrolyte contacts the eyes, flush thor- oughly and immediately with water and seek medical attention; and

Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to use a solution of 1 pound (500 grams) bicarbonate of soda to 1 gallon (4 liters) of water. The bicar- bonate of soda solution is to be added until the evidence of reaction (foaming) has ceased. The resulting liquid is to be flushed with water and the area dried.

Lead-acid batteries present a risk of fire because they generate hydrogen gas. The following procedures are to be followed:

DO NOT SMOKE when near the battery;

DO NOT cause flame or spark in battery area; and

Discharge static electricity from body before touch- ing the battery by first touching a grounded metal surface.

Be sure the AUTO/OFF/MANUAL switch is set to the OFF position before connecting the battery cables. If the switch is set to AUTO or MANUAL, the generator can crank and start as soon as the battery cables are connected.

Be sure the utility power supply is turned off and the 15A fuse is removed from the generator control panel, or sparking may occur at the bat- tery posts as the cables are attached and cause an explosion.

Servicing of the battery is to be performed or super- vised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized person- nel away from batteries.

See the Specifications section for the correct size and rating when replacing the battery. When using a maintenance-free battery, it is not necessary to check the specific gravity or electrolyte level. Have these procedures performed at the intervals specified in the “Service Schedule.” A negative ground system is used. Battery connections are shown on the wiring diagrams. Make sure the battery is correctly connect- ed and terminals are tight. Observe battery polarity when connecting the battery to the generator set.

11

Image 13
Contents Listed Authorized Dealer Location IntroductionMaintenance Post Installation Start-up AdjustmentsTroubleshooting Introduction Inside Front Cover Warning  ‹ Standards Index  Electrical Hazards Protection Systems UNPACKING/INSPECTIONBreaker for Bedrooms 7kW, Single Cylinder GH-410 Engine Generator‹ 1.5.1 Generator Specifications‹ 1.5.2 Engine Fuel Requirements Recommendations System SET LEDFuel Consumption ‹ 1.8.1 BTU Flow Requirements Natural GAS‹ 1.9.1 7 KW, 410CC Engine Reconfiguring the Fuel System‹ 1.9.2 10, 13 and 16KW, V-TWIN Engines ‹ 1.10.1 Generator LocationBattery Installation Battery Requirements‹ 1.10.2 Transfer Switch 10.2.1 7, 10, 13, and 16 kW Units if equipped10 Battery Cable Connections BatteryBefore Initial START-UP Check Transfer Switch OperationElectrical Checks Checking Automatic Operation Generator Tests Under Load7KW Natural GAS only ‹ 2.7.1 7 KW Units Engine Governor Adjustment‹ 3.1.3 Manual Position ‹ 3.1.1 Auto PositionSequence of Automatic Operation Automatic Transfer OperationManual Transfer Operation ‹ 3.1.4 Choke Operation‹ 3.4.2 Transfer Back to Utility Power Source Setting the Exercise Timer‹ 3.6.2 High Temperature Switch ‹ 3.6.1 LOW OIL Pressure Switch‹ 3.6.3 Overcrank Approximate Crank Cycle TimesChecking the Engine OIL Level ‹ 3.6.6 LOW BatteryFuses ‹ 3.6.5 RPM Sensor Failure‹ 4.3.1 OIL Change Intervals Changing the Engine OIL‹ 4.3.2 Engine OIL Recommendations ‹ 4.4.1 7, 13, and 16KW Generators Spark Plugs‹ 4.4.2 10KW Generators Valve Clearance Battery Maintenance11 Cooling Vent Locations Cooling System‹ 4.11.2 Return to Service OUT of Service Procedure‹ 4.11.1 Removal from Service Corrosion ProtectionBe performed by the nearest Authorized Dealer Service ScheduleProblem Cause Correction Troubleshooting GuideAir-cooled Generators Air-cooled Generators Air-cooled Generators Mounting Dimensions Electrical Data Engine Wiring Customer Connection Battery Charger Engine Alternator Engine Wiring Control Panel BOX Electronic Voltage Regulator Manual Auto Scsm Neutral Electrical Data Electrical Data Sheet Metal PAINT/MATERIAL Code Legend Part NO. QTY. Description Air-cooled Generators Control Panel Drawing No F9695-B QTY Description Exploded Views and Parts Lists BOX Load Center Exploded Views and Parts Lists Description QTY Exploded Views and Parts Lists Washer Flat M8 5/16 Exploded Views and Parts Lists Crankcase Exploded Views and Parts Lists Intake Adapter Exploded Views and Parts Lists PIN, Piston D20 Exploded Views and Parts Lists SCREW, Taptite M6-1.0X8 Yellow Chrome Air-cooled Generators 7kW, GN-410 Engine Drawing No F9422-B ADAPTOR, Engine Exploded Views and Parts Lists ADATOR, Engine 7KW CASTING, Twin Regulator Housing 7KW Exploded Views and Parts Lists Brkt Regulator Mounting MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule

005241, 005240, 005242, 005244, 005243 specifications

Guardian Technologies has established itself as a leading provider of innovative air purification solutions, leveraging advanced technologies to create healthier indoor environments. Their product line, including models 005281, 005282, 005283, 005284, and 005280, demonstrates the company's commitment to quality, efficiency, and ease of use.

One of the outstanding features of these models is their incorporation of HEPA filtration technology. This type of filter is capable of trapping at least 99.97% of airborne particles that are 0.3 microns in diameter, which includes allergens such as pollen, dust mites, and pet dander. This ensures that users can breathe cleaner air, making these devices ideal for allergy sufferers or anyone looking to improve their indoor air quality.

In addition to HEPA filtration, Guardian Technologies' models utilize ultraviolet (UV-C) light technology. This feature targets and neutralizes airborne viruses and bacteria, further enhancing the effectiveness of the air purification process. The combination of HEPA filtration and UV-C technology makes these devices equipped to handle a wide range of indoor air quality concerns.

Another significant characteristic of these products is their energy efficiency. Designed to operate quietly and with low power consumption, these air purifiers are not only effective but also environmentally friendly. Users can enjoy clean air without worrying about their energy bills or the environmental impact.

Furthermore, the user-friendly design of these models is notable. Many units come with intuitive controls, multiple fan speeds, and filter replacement indicators, making it easy for users to maintain optimal performance. Some models may also feature smart capabilities, allowing users to monitor air quality levels and control the device remotely via a smartphone app.

Durability is another hallmark of Guardian Technologies. Their products are built to last, using high-quality materials and components that ensure long-term reliability. This commitment to longevity adds value to the investment, as users can expect years of effective air purification.

In conclusion, Guardian Technologies' models 005281, 005282, 005283, 005284, and 005280 embody innovative features and technologies that cater to diverse air quality needs. From advanced filtration systems to energy-efficient designs, these purifiers not only enhance indoor air quality but also promote a healthier living environment for all users.