Guardian Technologies 005280, 005281, 005282, 005283, 005284 Battery Maintenance, Valve Clearance

Page 24

Section 4 — Maintenance

Air-cooled Generators

3.Check the spark plug gap using a wire feeler gauge. Adjust the gap to 0.76 mm (0.030 inch) for 7 and 10kW; and 1.02 mm (0.040 inch) for 13/16 kW by carefully bending the ground electrode (Figure 4.9).

Figure 4.9 – Setting the Spark Plug Gap

SET PLUG GAP AT 0.76 mm (.030 inch) - 7 & 10kW;

1.02 mm (.040 inch) - 13& 16kW

4.6BATTERY MAINTENANCE

The battery should be inspected per the "Service Schedule" section. The following procedure should be followed for inspection:

1.Inspect the battery posts and cables for tightness and corrosion. Tighten and clean as necessary.

2.Check the battery fluid level of unsealed batteries and, if necessary, fill with Distilled Water Only. Do not use tap water in batteries.

3.Have the state of charge and condition checked. This should be done with an automotive-type bat- tery hydrometer.

DANGER

Do not dispose of the battery in a fire. The battery is capable of exploding.

A battery presents a risk of electrical shock

and high short circuit current. The following pre- cautions are to be observed when working on batteries:

Remove the 15A fuse from the generator control panel.

Remove watches, rings or other metal objects;

Use tools with insulated handles;

Wear rubber gloves and boots;

Do not lay tools or metal parts on top of the battery; and

Disconnect charging source prior to connecting or disconnecting battery terminals.

Do not open or mutilate the battery. Released electrolyte has been known to be harmful to the skin and eyes, and to be toxic.

22

The electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes. It is electrically conductive and corrosive. The following procedures are to be observed:

Wear full eye protection and protective clothing;

Where electrolyte contacts the skin, wash it off immediately with water;

Where electrolyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention; and

Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to use a solution of 1 pound (500 grams) bicarbonate of soda to 1 gallon (4 liters) of water. The bicar- bonate of soda solution is to be added until the evidence of reaction (foaming) has ceased. The resulting liquid is to be flushed with water and the area dried.

Lead-acid batteries present a risk of fire because they generate hydrogen gas. The

following procedures are to be followed:

DO NOT SMOKE when near the battery;

DO NOT cause flame or spark in battery area; and

Discharge static electricity from body before touch- ing the battery by first touching a grounded metal surface.

Be sure the AUTO/OFF/MANUAL switch is set to the OFF position before connecting the battery cables. If the switch is set to AUTO or MANUAL, the generator can crank and start as soon as the battery cables are connected.

Be sure the utility power supply is turned off and the 15A fuse is removed from the generator control panel, or sparking may occur at the bat- tery posts as the cables are attached and cause an explosion.

4.7ADJUSTING GH-410/GT-530/990

VALVE CLEARANCE

After the first six (6) months of operation, check the valve clearance in the engine, adjust if neces- sary.

Important: If feeling uncomfortable about doing this procedure or the proper tools are not available, please contact the Authorized Dealer for service assistance. This is a very important step to insure longest life for the engine.

To check valve clearance:

The engine should be cool before checking. If valve clearance is 0.002" - 0.004" (0.05 - 0.1mm), adjustment is not needed.

Image 24
Contents Listed Introduction Authorized Dealer LocationPost Installation Start-up Adjustments MaintenanceTroubleshooting Introduction Inside Front Cover Warning   Electrical Hazards  ‹ Standards IndexUNPACKING/INSPECTION Protection SystemsBreaker for Bedrooms Generator 7kW, Single Cylinder GH-410 EngineSpecifications ‹ 1.5.1 Generator‹ 1.5.2 Engine System SET LED Fuel Requirements RecommendationsFuel Consumption ‹ 1.8.1 BTU Flow Requirements Natural GASReconfiguring the Fuel System ‹ 1.9.1 7 KW, 410CC Engine‹ 1.9.2 10, 13 and 16KW, V-TWIN Engines Location ‹ 1.10.1 GeneratorBattery Requirements Battery Installation‹ 1.10.2 Transfer Switch 10.2.1 7, 10, 13, and 16 kW Units if equippedBattery 10 Battery Cable ConnectionsCheck Transfer Switch Operation Before Initial START-UPElectrical Checks Generator Tests Under Load Checking Automatic Operation7KW Natural GAS only Engine Governor Adjustment ‹ 2.7.1 7 KW Units‹ 3.1.1 Auto Position ‹ 3.1.3 Manual PositionAutomatic Transfer Operation Sequence of Automatic OperationManual Transfer Operation ‹ 3.1.4 Choke OperationSetting the Exercise Timer ‹ 3.4.2 Transfer Back to Utility Power Source‹ 3.6.1 LOW OIL Pressure Switch ‹ 3.6.2 High Temperature Switch‹ 3.6.3 Overcrank Approximate Crank Cycle Times‹ 3.6.6 LOW Battery Checking the Engine OIL LevelFuses ‹ 3.6.5 RPM Sensor FailureChanging the Engine OIL ‹ 4.3.1 OIL Change Intervals‹ 4.3.2 Engine OIL Recommendations Spark Plugs ‹ 4.4.1 7, 13, and 16KW Generators‹ 4.4.2 10KW Generators Battery Maintenance Valve ClearanceCooling System 11 Cooling Vent LocationsOUT of Service Procedure ‹ 4.11.2 Return to Service‹ 4.11.1 Removal from Service Corrosion ProtectionService Schedule Be performed by the nearest Authorized DealerTroubleshooting Guide Problem Cause CorrectionAir-cooled Generators Air-cooled Generators Air-cooled Generators Mounting Dimensions Electrical Data Engine Wiring Customer Connection Battery Charger Engine Alternator Engine Wiring Control Panel BOX Electronic Voltage Regulator Manual Auto Scsm Neutral Electrical Data Electrical Data Sheet Metal PAINT/MATERIAL Code Legend Part NO. QTY. Description Air-cooled Generators Control Panel Drawing No F9695-B QTY Description Exploded Views and Parts Lists BOX Load Center Exploded Views and Parts Lists Description QTY Exploded Views and Parts Lists Washer Flat M8 5/16 Exploded Views and Parts Lists Crankcase Exploded Views and Parts Lists Intake Adapter Exploded Views and Parts Lists PIN, Piston D20 Exploded Views and Parts Lists SCREW, Taptite M6-1.0X8 Yellow Chrome Air-cooled Generators 7kW, GN-410 Engine Drawing No F9422-B ADAPTOR, Engine Exploded Views and Parts Lists ADATOR, Engine 7KW CASTING, Twin Regulator Housing 7KW Exploded Views and Parts Lists Brkt Regulator Mounting Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule

005241, 005240, 005242, 005244, 005243 specifications

Guardian Technologies has established itself as a leading provider of innovative air purification solutions, leveraging advanced technologies to create healthier indoor environments. Their product line, including models 005281, 005282, 005283, 005284, and 005280, demonstrates the company's commitment to quality, efficiency, and ease of use.

One of the outstanding features of these models is their incorporation of HEPA filtration technology. This type of filter is capable of trapping at least 99.97% of airborne particles that are 0.3 microns in diameter, which includes allergens such as pollen, dust mites, and pet dander. This ensures that users can breathe cleaner air, making these devices ideal for allergy sufferers or anyone looking to improve their indoor air quality.

In addition to HEPA filtration, Guardian Technologies' models utilize ultraviolet (UV-C) light technology. This feature targets and neutralizes airborne viruses and bacteria, further enhancing the effectiveness of the air purification process. The combination of HEPA filtration and UV-C technology makes these devices equipped to handle a wide range of indoor air quality concerns.

Another significant characteristic of these products is their energy efficiency. Designed to operate quietly and with low power consumption, these air purifiers are not only effective but also environmentally friendly. Users can enjoy clean air without worrying about their energy bills or the environmental impact.

Furthermore, the user-friendly design of these models is notable. Many units come with intuitive controls, multiple fan speeds, and filter replacement indicators, making it easy for users to maintain optimal performance. Some models may also feature smart capabilities, allowing users to monitor air quality levels and control the device remotely via a smartphone app.

Durability is another hallmark of Guardian Technologies. Their products are built to last, using high-quality materials and components that ensure long-term reliability. This commitment to longevity adds value to the investment, as users can expect years of effective air purification.

In conclusion, Guardian Technologies' models 005281, 005282, 005283, 005284, and 005280 embody innovative features and technologies that cater to diverse air quality needs. From advanced filtration systems to energy-efficient designs, these purifiers not only enhance indoor air quality but also promote a healthier living environment for all users.