Air-cooled Generators

DANGER

Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, standards and regu- lations.

1.1UNPACKING/INSPECTION

After unpacking, carefully inspect the contents for damage.

This standby generator set is ready for installa- tion with a factory supplied and pre-mounted base pad and has a weather protective enclosure that is intended for outdoor installation only.

This UL listed standby generator set is packaged with an automatic transfer switch with built in load center. The combination transfer switch and load center is pre-wired with a two foot and 30 foot conduit. Circuit breakers for emergency circuit connections are included (if equipped).

This UL listed, 2-pole switch is rated at 100 AC amperes at 250 volts maximum. This transfer switch is for indoor use only (if equipped).

If this generator is used to power electrical load circuits normally powered by a utility power source, it is required by code to install a transfer switch. The transfer switch must effectively isolate the electrical system from the utility distribution system when the generator is operating (NEC 700, 701 & 702). Failure to isolate an electrical system by such means will result in damage to the gen- erator and also may result in injury or death to utility power workers due to backfeed of electrical energy.

If any loss or damage is noted at time of delivery, have the person(s) making the delivery note all damage on the freight bill or affix their signature under the consignor's memo of loss or damage.

If a loss or damage is noted after delivery, separate the damaged materials and contact the carrier for claim procedures.

“Concealed damage” is understood to mean damage to the contents of a package that is not in evidence at the time of delivery, but is discovered later.

1.2PROTECTION SYSTEMS

Unlike an automobile engine, the generator may have to run for long periods of time with no operator pres- ent to monitor engine conditions. For that reason, the engine is equipped with the following systems that protect it against potentially damaging conditions:

There are LED readouts on the control panel to notify personnel that one of these faults has occurred. There is also a System Set LED that is lit when all of the conditions described in section "System Set LED" are true. (See the "Protection Systems" section for details.)

1.3NEC REQUIREMENT FOR ARC FAULT CIRCUIT INTERRUPTION

BREAKER FOR BEDROOMS

In 2001, the National Electric Code (NEC) intro- duced a requirement for new construction. This new requirement indicates the need for Arc Fault Circuit Interrupters to be used to protect the complete branch circuit that feeds a dwelling bedroom. The actual NEC requirement is indicated below.

‹1.3.1 SECTION 210.12 ARC FAULT CIRCUIT INTERRUPTER PROTECTION

1.Definition: An arc fault circuit interrupter is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by functioning to de-ener- gize the circuit when an arc fault is detected.

2.Dwelling Unit Bedrooms: All branch circuits that supply 125 volt, single-phase, 15 and 20 ampere outlets installed in dwelling unit bedrooms shall be protected by an arc fault circuit interrupter listed to provide protection of the entire branch circuit.

Section 210.12 requires that AFCI protection be provided on branch circuits that supply outlets (receptacle, lighting, etc.) in dwelling bedrooms. The requirement is limited to 15 and 20 ampere, 125 volt circuits. There is no prohibition against provid- ing AFCI protection on other circuits or in locations other than bedrooms. Because circuits are often shared between a bedroom and other areas such as closets and hallways, providing AFCI protection on the complete circuit would comply with 210.12.

If during the installation of the home standby system the decision is made to provide back up power to a bedroom branch circuit, then the circuit breaker in the transfer switch should be replaced with an Arc Fault Circuit Interrupter.

It is most important that breakers only be switched like for like. For instance, if replacing a 15A breaker, it MUST be replaced with a 15A AFCI breaker. Likewise, a 20A breaker MUST be replaced with a 20A AFCI.

These AFCI breakers are available at the nearest hardware store.

1.

Low Oil Pressure Sensor

4.

Overspeed

Siemens Item #

Description

Q115AF

15A Single Pole AFCI

2.

High Temperature Sensor

5.

RPM Sensor

3.

Overcrank

6.

Low Battery

Q120AF

20A Single Pole AFCI

4

Image 6
Contents Listed Introduction Authorized Dealer LocationTroubleshooting Post Installation Start-up AdjustmentsMaintenance Introduction Inside Front Cover Warning   Electrical Hazards  ‹ Standards IndexUNPACKING/INSPECTION Protection SystemsBreaker for Bedrooms Generator 7kW, Single Cylinder GH-410 EngineSpecifications ‹ 1.5.1 Generator‹ 1.5.2 Engine Fuel Consumption System SET LEDFuel Requirements Recommendations ‹ 1.8.1 BTU Flow Requirements Natural GASReconfiguring the Fuel System ‹ 1.9.1 7 KW, 410CC Engine‹ 1.9.2 10, 13 and 16KW, V-TWIN Engines Location ‹ 1.10.1 Generator‹ 1.10.2 Transfer Switch Battery RequirementsBattery Installation 10.2.1 7, 10, 13, and 16 kW Units if equippedBattery 10 Battery Cable ConnectionsCheck Transfer Switch Operation Before Initial START-UPElectrical Checks Generator Tests Under Load Checking Automatic Operation7KW Natural GAS only Engine Governor Adjustment ‹ 2.7.1 7 KW Units‹ 3.1.1 Auto Position ‹ 3.1.3 Manual PositionManual Transfer Operation Automatic Transfer OperationSequence of Automatic Operation ‹ 3.1.4 Choke OperationSetting the Exercise Timer ‹ 3.4.2 Transfer Back to Utility Power Source‹ 3.6.3 Overcrank ‹ 3.6.1 LOW OIL Pressure Switch‹ 3.6.2 High Temperature Switch Approximate Crank Cycle TimesFuses ‹ 3.6.6 LOW BatteryChecking the Engine OIL Level ‹ 3.6.5 RPM Sensor FailureChanging the Engine OIL ‹ 4.3.1 OIL Change Intervals‹ 4.3.2 Engine OIL Recommendations Spark Plugs ‹ 4.4.1 7, 13, and 16KW Generators‹ 4.4.2 10KW Generators Battery Maintenance Valve ClearanceCooling System 11 Cooling Vent Locations‹ 4.11.1 Removal from Service OUT of Service Procedure‹ 4.11.2 Return to Service Corrosion ProtectionService Schedule Be performed by the nearest Authorized DealerTroubleshooting Guide Problem Cause CorrectionAir-cooled Generators Air-cooled Generators Air-cooled Generators Mounting Dimensions Electrical Data Engine Wiring Customer Connection Battery Charger Engine Alternator Engine Wiring Control Panel BOX Electronic Voltage Regulator Manual Auto Scsm Neutral Electrical Data Electrical Data Sheet Metal PAINT/MATERIAL Code Legend Part NO. QTY. Description Air-cooled Generators Control Panel Drawing No F9695-B QTY Description Exploded Views and Parts Lists BOX Load Center Exploded Views and Parts Lists Description QTY Exploded Views and Parts Lists Washer Flat M8 5/16 Exploded Views and Parts Lists Crankcase Exploded Views and Parts Lists Intake Adapter Exploded Views and Parts Lists PIN, Piston D20 Exploded Views and Parts Lists SCREW, Taptite M6-1.0X8 Yellow Chrome Air-cooled Generators 7kW, GN-410 Engine Drawing No F9422-B ADAPTOR, Engine Exploded Views and Parts Lists ADATOR, Engine 7KW CASTING, Twin Regulator Housing 7KW Exploded Views and Parts Lists Brkt Regulator Mounting Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule

005241, 005240, 005242, 005244, 005243 specifications

Guardian Technologies has established itself as a leading provider of innovative air purification solutions, leveraging advanced technologies to create healthier indoor environments. Their product line, including models 005281, 005282, 005283, 005284, and 005280, demonstrates the company's commitment to quality, efficiency, and ease of use.

One of the outstanding features of these models is their incorporation of HEPA filtration technology. This type of filter is capable of trapping at least 99.97% of airborne particles that are 0.3 microns in diameter, which includes allergens such as pollen, dust mites, and pet dander. This ensures that users can breathe cleaner air, making these devices ideal for allergy sufferers or anyone looking to improve their indoor air quality.

In addition to HEPA filtration, Guardian Technologies' models utilize ultraviolet (UV-C) light technology. This feature targets and neutralizes airborne viruses and bacteria, further enhancing the effectiveness of the air purification process. The combination of HEPA filtration and UV-C technology makes these devices equipped to handle a wide range of indoor air quality concerns.

Another significant characteristic of these products is their energy efficiency. Designed to operate quietly and with low power consumption, these air purifiers are not only effective but also environmentally friendly. Users can enjoy clean air without worrying about their energy bills or the environmental impact.

Furthermore, the user-friendly design of these models is notable. Many units come with intuitive controls, multiple fan speeds, and filter replacement indicators, making it easy for users to maintain optimal performance. Some models may also feature smart capabilities, allowing users to monitor air quality levels and control the device remotely via a smartphone app.

Durability is another hallmark of Guardian Technologies. Their products are built to last, using high-quality materials and components that ensure long-term reliability. This commitment to longevity adds value to the investment, as users can expect years of effective air purification.

In conclusion, Guardian Technologies' models 005281, 005282, 005283, 005284, and 005280 embody innovative features and technologies that cater to diverse air quality needs. From advanced filtration systems to energy-efficient designs, these purifiers not only enhance indoor air quality but also promote a healthier living environment for all users.