Global Machinery Company GEN2300ES Automatic voltage regulator AVR, Preparing the generator

Page 12

Automatic voltage regulator (AVR)

This generator has been equipped with AVR technology which provides automatic voltage regulated power for continuous uninterrupted stable power supply.

The AVR maintains a regulated AC output and reacts substantially quicker to rapid surges in voltage, therefore, preventing the possibility of damage to the generator and attached equipment.

Preparing the generator

It is important to check the generator before you commence operating the unit.

IMPORTANT. Ensure that the engine has oil. When leaving the factory, this generator has NO OIL in the engine.

Note. The engine will not start if the generator has no oil.

Checking the engine fuel

Checking the engine oil

The motor of this generator is not filled with oil.

Prior to starting the motor ensure the crank case is filled with SAE #30 4 stroke oil.

Damage to the motor is not covered under warranty if the motor is run without oil.

1.Before checking or refilling oil, be sure the generator is put on a stable and level surface, ensuring the engine has been switched OFF.

2.Remove the oil filler cap (7) by rotating the cap anti- clockwise and inspect to see the oil level.

3.If the oil level is below the lower level line, refill with SAE #30 4 stroke oil to the upper level line.

Note. Do not screw in the oil filler cap (7) when checking oil level, simply insert and pull the cap straight out.

1.

Switch off engine by turning the ignition switch (10) to

 

the ‘off’ position.

2.

Check the fuel level by viewing the fuel level gauge (3).

3.

If the fuel is low, remove the fuel cap (2) by turning

 

anticlockwise.

4.

Check to ensure the fuel filter screen is inside the fuel

 

filter neck.

5.

Pour the unleaded fuel from an approve fuel container

 

into the fuel tank (1). Because fuel expands, DO NOT

 

FILL to the lip of the tank.

6.

Replace fuel cap (2) and turn clockwise to lock.

WARNING.

4.If the oil is contaminated or has discoloured, ensure you change the oil. Refer to the ‘Engine oil replacement’

section for instructions.

Note. This motor is fitted with a low oil sensor. If the oil level is too low the motor will stop operating or the motor will not start. It is advised to

check the oil level each time the generator is used.

Oil filler cap (oil gauge)

Upper level

Lower level

Do not refill fuel tank (1) while engine is running or is hot.

Check to ensure that the fuel drain (16) has been tightened and that fuel is not leaking.

Be careful not to admit dust, dirt, water or other foreign objects into the fuel.

Wipe off spilt fuel thoroughly before starting engine.

Ensure you DO NOT fuel the generator in close proximity to any open flames.

Connecting the battery

 

A

Note. Before using the key

 

start function of the generator

 

you must connect the battery to

 

the generator.

 

1. Firmly take hold of both

 

plugs and insert one into

 

the other until they ‘click’

 

into place (Fig. A).

 

 

12

Image 12
Contents 2300W AVR Petrol Generator Contents Description of symbols SpecificationsIntroduction Environmental protectionSafety instructions Electrical safetyPage Risk of electrocution and fire Risk of fire Risk of breathing inhalation hazard Risk of unsafe operationRisk of hot surfaces Risk of moving partsRisk from lifting Generator componentsAdditional safety rules for generators UnpackingKnow your product Connecting the battery Automatic voltage regulator AVRPreparing the generator Checking the engine fuel Checking the engine oilStarting the engine with key start Starting the engine manuallyStopping the engine ‘Starting the engine with key start’ sectionConnecting apparatus to the generator Charging the batteryAC safety switch Safety switch trippingGenerator maintenance DC overload cut outPeriodic maintenance Engine oil replacement StorageSpark plugs Air filterPetrol tank filter Tap extension fuel filterCleaning RepairsTroubleshooting No electrical outputRepeated circuit breaker TrippingPage Page GMC customer assist

GEN2300ES specifications

The Global Machinery Company GEN2300ES is an innovative power generator designed to meet the needs of both residential and commercial users. This portable inverter generator is known for its reliability, efficiency, and versatile features, making it a popular choice among users seeking a dependable power source for various applications.

One of the standout features of the GEN2300ES is its impressive fuel efficiency, allowing it to operate for extended periods on a single tank. With a 2.3-gallon fuel capacity, it can deliver up to 10 hours of continuous power at a 25% load. This efficiency not only saves users money on fuel costs but also enhances its suitability for outdoor adventures, job sites, and emergency backup situations.

The GEN2300ES is powered by a robust engine that produces a clean and stable output. Thanks to its inverter technology, the generator is capable of producing pure sine wave power, making it safe for sensitive electronics, including laptops, smartphones, and medical devices. This makes it an ideal choice for users who require reliable power without any risk of damage to their equipment.

Another significant characteristic of the GEN2300ES is its lightweight and compact design. Weighing approximately 49 pounds, it features an ergonomic handle that makes it easy to transport. This portability is a crucial factor for campers, tailgaters, and users needing power on the go.

Furthermore, the GEN2300ES incorporates several user-friendly technologies. Its advanced digital display provides real-time updates on wattage usage, remaining run time, and maintenance alerts, ensuring that users can keep track of their generator’s performance. Additionally, it is equipped with a quiet operation system, producing only 52 dBA at a quarter load, allowing for peaceful surroundings during use.

Safety features are also paramount in the GEN2300ES design. It includes overload protection and low oil shut-off mechanisms to prevent engine damage. The generator is also compliant with EPA and CARB regulations, reflecting its commitment to environmental standards and user safety.

In conclusion, the Global Machinery Company GEN2300ES is a cutting-edge portable inverter generator that combines efficiency, portability, and advanced technology. With its rigorous safety features and ability to deliver clean power, it stands out as a reliable choice for users seeking to maintain power in diverse scenarios.