Global Machinery Company GEN2300ES Connecting apparatus to the generator, Charging the battery

Page 14

Connecting apparatus to the generator

1.Start the engine. Allow the motor to run for a couple of minutes to warm up prior to connecting any apparatus to the generator.

2.For AC current, ensure the

safety switch (4) is turned I

OFF first, then plug the power cord into the AC output socket (8) (Fig. I).

3.Switch the AC safety switch

(4) to the ‘ON’ position. Note: ALWAYS use three-pronged plugs for AC apparatus.

CAUTION.

 

J

Ensure the electric

 

apparatus is turned off

 

before plugging in.

 

Check to ensure that the total load is within the generator rated output.

3.For DC current, plug into the DC outlet socket (9)

(Fig. J). To charge your car battery, connect the DC plug (19) which have alligator clips to the corresponding terminals on your battery. The red lead goes to the positive

(+) terminal and the black lead goes to the negative (-) terminal. This DC cord has been supplied with the unit.

Note. This usage is applicable for charging only 12V batteries. Only use the DC plug (19) to charge lead acid type batteries. DO NOT charge Nicad or any other type of batteries.

Charging the battery

1.Disconnect the leads from the battery.

2.Fully loosen the battery fluid filler caps.

3.Fill the battery cells with distilled water to the upper limit if the battery is empty.

 

gravitySpecific(20C)

1.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

chargingandgravitytime

1.26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

1.22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

1.18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.10

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

specificfor

 

1.06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery : Battery capacity

 

 

 

 

 

 

 

 

0

2

4

6

8

10

 

 

 

 

Charging time (Hr)

 

 

Aim

1

: (30Ah)

 

 

 

 

 

 

 

 

 

 

2

: (35Ah)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

: (47Ah)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Measure the specific gravity fluid by using a hydrometer and calculate the charging time in accordance with the table shown.

5. For a fully charged battery, the specific gravity range shall be within 1.26 to 1.28. It is recommended to be checked and confirmed every hour.

6. Connect the DC plug lead (19) into the DC socket (9) and connect the alligator clips to the correct polarity.

Press the DC reset button (5) to reset in case the DC supply had previously been overloaded.

The generator will charge batteries up to 600CCA capacity provided the battery is in reasonable condition.

Batteries of larger capacity may charge but will depend on the condition and also the level of charge in the battery.

In cases where the current exceeds the rating of the generator, the circuit breaker on the DC side will open circuit, and will need to be reset to continue.

14

Image 14
Contents 2300W AVR Petrol Generator Contents Introduction Description of symbolsSpecifications Environmental protectionSafety instructions Electrical safetyPage Risk of electrocution and fire Risk of fire Risk of breathing inhalation hazard Risk of unsafe operationRisk from lifting Risk of hot surfacesRisk of moving parts Generator componentsAdditional safety rules for generators UnpackingKnow your product Preparing the generator Connecting the batteryAutomatic voltage regulator AVR Checking the engine fuel Checking the engine oilStopping the engine Starting the engine with key startStarting the engine manually ‘Starting the engine with key start’ sectionConnecting apparatus to the generator Charging the batteryAC safety switch Safety switch trippingGenerator maintenance DC overload cut outPeriodic maintenance Spark plugs Engine oil replacementStorage Air filterPetrol tank filter Tap extension fuel filterCleaning RepairsRepeated circuit breaker TroubleshootingNo electrical output TrippingPage Page GMC customer assist

GEN2300ES specifications

The Global Machinery Company GEN2300ES is an innovative power generator designed to meet the needs of both residential and commercial users. This portable inverter generator is known for its reliability, efficiency, and versatile features, making it a popular choice among users seeking a dependable power source for various applications.

One of the standout features of the GEN2300ES is its impressive fuel efficiency, allowing it to operate for extended periods on a single tank. With a 2.3-gallon fuel capacity, it can deliver up to 10 hours of continuous power at a 25% load. This efficiency not only saves users money on fuel costs but also enhances its suitability for outdoor adventures, job sites, and emergency backup situations.

The GEN2300ES is powered by a robust engine that produces a clean and stable output. Thanks to its inverter technology, the generator is capable of producing pure sine wave power, making it safe for sensitive electronics, including laptops, smartphones, and medical devices. This makes it an ideal choice for users who require reliable power without any risk of damage to their equipment.

Another significant characteristic of the GEN2300ES is its lightweight and compact design. Weighing approximately 49 pounds, it features an ergonomic handle that makes it easy to transport. This portability is a crucial factor for campers, tailgaters, and users needing power on the go.

Furthermore, the GEN2300ES incorporates several user-friendly technologies. Its advanced digital display provides real-time updates on wattage usage, remaining run time, and maintenance alerts, ensuring that users can keep track of their generator’s performance. Additionally, it is equipped with a quiet operation system, producing only 52 dBA at a quarter load, allowing for peaceful surroundings during use.

Safety features are also paramount in the GEN2300ES design. It includes overload protection and low oil shut-off mechanisms to prevent engine damage. The generator is also compliant with EPA and CARB regulations, reflecting its commitment to environmental standards and user safety.

In conclusion, the Global Machinery Company GEN2300ES is a cutting-edge portable inverter generator that combines efficiency, portability, and advanced technology. With its rigorous safety features and ability to deliver clean power, it stands out as a reliable choice for users seeking to maintain power in diverse scenarios.