Generac Power Systems 005223-0 owner manual Equipment Description, Engine OIL Recommendations

Page 7

Standby Generator Sets Equipment Description

EQUIPMENT DESCRIPTION

This equipment is a revolving field, alternating cur- rent generator set. It is powered by a gaseous fueled engine operating at 1800 rpm for 4-pole direct drive units, 3600 rpm for 2-pole direct drive units and 2300 - 3000 rpm for quiet drive gear units. See the Specifications section for exact numbers. The unit comes complete with a sound attenuated enclosure, internally mounted muffler, control console, main- line circuit breaker, battery charger, and protective alarms as explained in the following paragraph.

All AC connections, including the power leads from the alternator, 120 volt battery charger input and control connections to the transfer switch are avail- able in the main connection box.

The generator incorporates the following generator features:

Rotor and Stator insulation is Class H rated as defined by NEMA MG1-32.6, NEMA MG1-1.66. The generator is self ventilated and drip-proof con- structed.

The voltage waveform deviation, total harmonic content of the AC waveform and telephone influ- ence factor have been evaluated and are acceptable according to NEMA MG1-32.

ENGINE OIL RECOMMENDATIONS

The unit has been filled with 15W-40 engine oil at the factory. Use a high-quality detergent oil classified “For Service CC, SD, SE, SF.” Detergent oils keep the engine cleaner and reduce carbon deposits. Use oil having the following SAE viscosity rating, based on the ambient temperature range anticipated before the next oil change:

 

Temperature

Oil Grade (Recommended)

 

 

Above 80° F (27° C)

SAE 30W or 15W-40

 

 

32° to 80° F (0° to 27° C)

SAE 20W-20 or 15W-40

 

 

Below 32° F (0° C)

See Note

 

Any attempt to crank or start the engine before it has been properly serviced with the recom- mended oil may result in an engine failure.

NOTE:

COOLANT RECOMMENDATIONS

Use a mixture of half low silicate ethylene glycol base anti-freeze and deionized water. Cooling system capacity is listed in the specifications. Use only deion- ized water and only low silicate anti-freeze. If desired, add a high quality rust inhibitor to the recommended coolant mixture. When adding coolant, always add the recommended 50-50 mixture.

Do not use any chromate base rust inhibitor with ethylene glycol base anti-freeze or chro- mium hydroxide (“green slime”) forms and will cause overheating. Engines that have been oper- ated with a chromate base rust inhibitor must be chemically cleaned before adding ethylene glycol base anti-freeze. Using any high silicate anti-freeze boosters or additives will also cause overheating. The manufacturer also recommends that any soluble oil inhibitor is NOT used for this equipment.

DANGER

Do not remove the radiator pressure cap while the engine is hot or serious burns from boiling liquid or steam could result.

Ethylene glycol base antifreeze is poisonous. Do not use mouth to siphon coolant from the radiator, recovery bottle or any container. Wash hands thoroughly after handling. Never store used antifreeze in an open container because animals are attracted to the smell and taste of antifreeze even though it is poisonous to them.

For temperatures below 32° F, it is strongly recom- mended to use the optional Cold Weather Start Kit (part number listed in the Specification Section). The oil grade for temperatures below 32° F is 5W- 30 synthetic oil.

3-1

08/05

0 .Rev Equip001

Image 7
Contents Centurion Standby Generator Sets Table of Contents  Warning   Electrical Hazards  Introduction ‹ Operation and Maintenance‹ HOW to Obtain Service Authorized Service Dealer Location‹ Data Label Identification RecordEngine OIL Recommendations Equipment DescriptionCoolant Recommendations Engine Protective Devices ‹ LP Fuel System Fuel System‹ Fuel Requirements ‹ Natural GAS Fuel SystemSpecifications ‹ Cold Weather KIT ‹ Reconfiguring the Fuel SystemGenerator AC Lead Connections Alternator Power Winding Connections‹ FOUR-LEAD, SINGLE-PHASE Stator ‹ 3-PHASE AlternatorsPreparation Before START-UP InstallationInitial Inspection for QT Genset Startup ‹ Preparation for START-UP START-UP Checklist‹ START-UP Inspection ‹ Retransfer and Shutdown Operating Unit with Manual Transfer SwitchGenerator Control Operation ‹ Engine START-UP and TransferChecking Fluid Levels Cooling SystemMaintenance Owner Operator can Perform Miscellaneous Maintenance ‹ Battery Maintenance Repair Parts‹ Battery Replacement KW 150 KW Standby GAS Engine Driven Generator Sets Service ScheduleMaintenance Level 11-3 11-4 Problem Cause Correction Troubleshooting GuideStandby Generator Sets Standby Generator Sets Standby Generator Sets Page PAN CB Conn BOX Page Assy RTR 390 30KD1 CPL Page MTG Base 3.9L 40KW C2 Page Tray Battery Page Flexplate HSB 3.9L Chrysler 1800RPM Page Encl HSB Control Panel Page Weldment RAD Support 3.9L C2 Page Pipe R/H Side Muffler Page Element AIR Filter Page Flange Fuel Inlet Page Rear Wrap C2 Page Page Page Page Page Page Standby Generator Sets Warranty

005223-0 specifications

Generac Power Systems has established itself as a prominent name in the field of power generation, and the Generac 005223-0 model exemplifies the company's commitment to innovative technology and reliable performance. This portable generator is designed for various applications, from home backup power to outdoor events, ensuring users have access to electricity when they need it the most.

One of the standout features of the Generac 005223-0 is its impressive power output. With a capacity that typically exceeds 3000 watts, this generator can handle essential home appliances, tools, and more, providing peace of mind during power outages or when electricity is required away from a stationary power source. The generator is equipped with a powerful, efficient engine that optimizes fuel consumption while delivering maximum performance.

In addition to its robust power capabilities, the 005223-0 incorporates Generac’s patented PowerRush technology, which enhances the starting capacity, allowing users to start larger loads such as air conditioners or power tools without any issue. This technology significantly increases the generator’s output upon startup, making it an excellent choice for users needing to power multiple devices simultaneously.

Safety is a primary concern for Generac, and the 005223-0 exemplifies this commitment through its built-in protection features. The generator includes low-oil shutdown, which automatically turns off the engine when the oil level drops too low, preventing damage and ensuring longevity. Furthermore, the unit is designed with a sturdy frame to withstand various conditions, making it suitable for both residential and commercial use.

Another notable characteristic of the 005223-0 is its user-friendly interface. The generator's control panel is intuitively laid out, providing easy access to power settings, fuel gauge, and various output options. This makes operation straightforward, even for those who are not well-versed in generator technology.

Lastly, portability is a key feature of the Generac 005223-0, as it is designed with rugged wheels and a lightweight structure, enabling easy transportation to different locations. Whether it’s for outdoor gatherings, camping trips, or emergency backup, this generator is exceptional in versatility and reliability. With the 005223-0, users can expect a seamless power solution backed by Generac’s reputation for quality and service.