Generac Power Systems 005261-1, 005262-1 owner manual Instr Hypot Test not Shown

Page 31

1

0G0056

1

RTR-2390--35KD1 CPL

 

0G1155

1

RTR-2390--35KD1 CPL (G2)

 

0F9677

1

RTR-2390--45KD1 CPL

 

0G0959

1

RTR-2390--45KD1 CPL (G2)

2

0G0057

1

STR-2390--35AD1 CPL

 

0F9664

1

STR 390 45K 2P 1PH DIRECT

 

0G0058

1

STR-2390--35KD1 CPL

 

0G0184

1

STR 390 45KW 2P 3PH 480V

 

0G0059

1

STR-2390--35GD1 CPL

 

0G0183

1

STR 390 45KW 2P 3PH 208V

3

0C9708

REF

INSTR HYPOT TEST (NOT SHOWN)

4

SEE ENGINE EV

REF

ENGINE ADAPTER

5

SEE ENGINE EV

REF

FLEXPLATE

6

0F5767B

1

ASSY FLYWHEEL CPL W/40MM FAN B

7

0E5706

1

REAR BEARING CARRIER 390/DRCT

8

0F7874

1

ASSY BRUSH HOLDER 390/HSB

9

0G0587

1

GUARD REAR BEARING CARRIER

10

038150

4

WASHER FLAT #8 ZINC

11

023454

1

KEY WOODRUFF #E

12

077043F

1

CONDUIT FLEX 1-1/4" (30” LG)

13

04576100BU

4

STUD M14-2.0 570 G5 ZINC

14

052646

4

WASHER FLAT M14

15

043123

4

WASHER LOCK M14

16

051779

4

NUT HEX M14-2.0 G8 YEL CHR

17

0A2601

1

SCREW HHC M16-2.0 X 45 G8.8

18

0A2602

1

WASHER FLAT .688 ID X 3.25 OD

19

0F8408

4

SCREW HHC M10-1.50 X 16 G10.9

20

046526

4

WASHER LOCK M10

21

0C3993

4

SCREW HHTT M4-0.7 X 25 BP

22

022264

4

WASHER LOCK #8-M4

23 *

047248

1

BALL BEARING-45 MM

24 *

070892

1

SLIP RING MACHINED

25

0G0588

1

GUARD REAR BEARING CARRIER

* ROTOR REPLACEMENT PARTS

Image 31
Contents New standard of reliability Standby Generator Sets Table of Contents  Warning   Electrical Hazards  Introduction ‹ Operation and Maintenance‹ HOW to Obtain Service Authorized Service Dealer Location‹ Data Label Identification RecordEngine OIL Recommendations Equipment DescriptionCoolant Recommendations Engine Protective Devices ‹ LP Fuel System Fuel System‹ Fuel Requirements ‹ Natural GAS Fuel SystemSpecifications ‹ Cold Weather KIT ‹ Reconfiguring the Fuel SystemGenerator AC Lead Connections Alternator Power Winding Connections‹ FOUR-LEAD, SINGLE-PHASE Stator ‹ 3-PHASE AlternatorsPreparation Before START-UP InstallationInitial Inspection for QT Genset Startup ‹ Preparation for START-UP START-UP Checklist‹ START-UP Inspection ‹ Retransfer and Shutdown Operating Unit with Manual Transfer SwitchGenerator Control Operation ‹ Engine START-UP and TransferChecking Fluid Levels Cooling SystemMaintenance Owner Operator can Perform ‹ Changing Engine OIL ‹ Changing the Engine AIR Cleaner ‹ Coolant Change‹ Spark Plugs ‹ Battery Maintenance Miscellaneous Maintenance‹ Cleaning the Generator ‹ BatteryKW 150 KW Standby GAS Engine Driven Generator Sets Service ScheduleMaintenance Level 11-3 11-4 Problem Cause Correction Troubleshooting GuideStandby Generator Sets Page PAN CB Conn BOX Page UL Circuit Breaker QJ-2P Page Instr Hypot Test not Shown Page Components Included in 0F9696E Page Components Included in 0G1290E Page Weldment Frame 2.4L C2 Page Battery Tray C1 CPL Page Gasket Bosch 32 Page Engine 2.4L G2 Rework Page Weldment Radiator Support 2.4L Page Flange Fuel Inlet Page Rear Wrap C2 CPL Page Bracket Muffler Page Page Page Page Page Page Page Page Page Page Page C2 Units Standby Generator Sets Warranty

005261-1, 005262-1 specifications

Generac Power Systems, a leader in backup power solutions, offers a range of generators designed to meet different power needs. Among their notable products are the Generac models 005261-1 and 005262-1, which are both excellent options for residential and commercial applications. These generators are specifically designed to provide reliable power during outages, ensuring that homes and businesses remain operational when it matters most.

One of the standout features of the Generac 005261-1 and 005262-1 models is their automatic transfer switch technology. This feature allows the generators to detect power outages automatically and switch on within seconds, providing uninterrupted power. The systems are designed for ease of use, with a user-friendly control panel that displays critical information about the generator’s status and maintenance requirements.

Both models are powered by Generac's innovative engine technology, which ensures superior performance and fuel efficiency. The engines are engineered to run quietly while delivering ample power output. The 005261-1 typically offers up to 22 kW of backup power, while the 005262-1 goes up to 26 kW, making them suitable for larger homes or essential commercial applications.

In terms of construction, the Generac models feature durable weather-resistant enclosures, ensuring they can withstand harsh environmental conditions. Their compact design makes installation straightforward, with options for both concrete pads and low-profile installations. Furthermore, both generators are equipped with a state-of-the-art digital controller that allows users to monitor the system remotely.

Another important characteristic is the Generac Power Zone Mobile Link, which allows users to monitor their generator’s status via a smartphone app. This feature provides peace of mind, as users can receive alerts regarding power outages, routine maintenance, and operational status in real time, even when they are not home.

The maintenance of these generators is simplified by their built-in features, including an integrated maintenance reminder system that alerts users when service is due. This proactive approach aids in extending the life of the generator and optimizing performance over time.

In summary, the Generac Power Systems models 005261-1 and 005262-1 offer a blend of reliability, efficiency, and advanced technology. With automatic transfer switches, robust engine design, and smart monitoring capabilities, these generators stand out in the market as excellent choices for backup power needs. Whether for residential use or light commercial applications, users can trust in Generac’s commitment to delivering dependable power solutions.