Dixon 6000 Series manual Care and Maintenance, Maintenance Schedule

Page 22

CARE AND MAINTENANCE

CAUTION

Before performing any maintenance, turn off engine, allow to cool, remove key and disconnect spark plugs. Use extreme care when working on machinery. Do not wear watch or jewelry. Do not wear loose fitting clothes, and observe all common safety practices with tools.

MAINTENANCE SCHEDULE

Check drive belts . . . . . . . . . . . . . . . . . . . . . . . every 50 hours (20 hours break-in)

Check crankcase oil level. . . . . . . . . . . . . . . . . . .before each use Clean grass from Hydrostat fans and cooling fans . . . . . .before each use Check air intake screen. . . . . . . . . . . . . . . . . . . . . after each use Clean grass under deck . . . . . . . . . . . . . . . . . . . . after each use Check tire pressure . . . . . . . . . . . . . . . . . . . . . . every 10 hours Check battery fluid . . . . . . . . . . . . . . . . . . . . . . every 10 hours Sharpen mower blades . . . . . . . . . . . . . . . . . . . . every 10 hours Check air filter element . . . . . . . . . . . . . . . . . . . . every 25 hours Check hydrostatic transmission fluid . . . . . . . . . . . . . every 25 hours Service engine air filter pre-cleaner . . . . . . . . . . . . . . every 25 hours Grease driveline (3 fittings) . . . . . . . . . . . . . . . . . . every 50 hours Grease jack shaft . . . . . . . . . . . . . . . . . . . . . . . every 50 hours Grease deck pivot tube . . . . . . . . . . . . . . . . . . . .every 50 hours Check adjustment of P.T.O. clutch. . . . . . . . . . . . . . .every 50 hours

(or if blades do not stop with 7 seconds from switch disengagement)

Service air filter element . . . . . . . . . . . . . . . . . . . .every 25 hours Change engine crankcase oil. . . . . . . . . . . . . . . . .every 100 hours

(5 hours break-in) Change engine oil filter. . . . . . . . . . . . . . . . . . . . every 100 hours

Change hydrostat oil filter (7252) . . . . . . . . . . . . . . every 500 hours (50 hours break-in)

Change oil in deck gearbox . . . . . . . . . . . annually or every 500 hours Replace air filter element. . . . . . . . . . . . . . . . . . . every 100 hours Check spark plugs. . . . . . . . . . . . . . . . annually or every 200 hours Service battery . . . . . . . . . . . . . . . . . . annually or every 500 hours

Note: Perform these maintenance procedures more frequently under extremely dusty, dirty conditions.

Replace decals when illegible.

Page 22

Image 22
Contents 6000 Important Read Carefully Index Safety Safety Alert Symbol General Operation Slope Operation Do notChildren Service Dixon Limited WARRANTYPOLICY- Commercialmodels Models6000&7000Specifications Series Forward MountSeat Adjustment Instructions Controls Control LocationsParking Brake To GO Backward Circuit Breaker Blade DriveMower Deck CUT Height Lift Lever Operation Instructions TowingTesting of Safety Interlock Systems Starting Instructions Cold Engine Unlock TransmissionStarting Instructions Engine has been operatedDischarge chute Grass Height SuggestionsCare and Maintenance Maintenance ScheduleEngine Mower Blades BeltsLubrication Checking & Replenishing OIL in Hydrostatic TransmissionHydrostatic Transmission Parking Brake AdjustmentScalper Roller Bolts Hydrostat Drive Belt Tension Adjustment Steering Control Adjustments Steering Control Adjustments Lower and Reattach the Deck see diagram-page Down Hanger Engagedposition Checking Deck Drive Gearbox Fluid Level Changing the Fluid in Deck Drive GearboxLeveling the Deck Deck Spindle Belt Diagram Model ZTR Standard Service Parts ListKohler AIR and OIL Filter Part Numbers Troubleshooting Engine Wont Turn OverEngine Idles Poorly Page Owner Information Date OIL Changed Date Engine TunedSeries 6022

6000 Series specifications

The Dixon 6000 Series is an advanced line of valves designed for a multitude of industrial applications, renowned for its durability, precision, and state-of-the-art technology. Designed to cater to the rigorous demands of various industries, including oil and gas, water management, and manufacturing, the 6000 Series stands out for its reliability and performance.

One of the main features of the Dixon 6000 Series is its robust construction. The valves are made from high-quality materials, including stainless steel and various alloys, ensuring excellent resistance to corrosion and wear. This construction allows the valves to operate in harsh environments, extending their lifespan and reducing maintenance costs.

In terms of technology, the Dixon 6000 Series incorporates advanced sealing mechanisms that provide a tight, leak-proof fit. The valves utilize a combination of O-ring seals and other gasket materials designed to withstand high pressure and temperature fluctuations, making them suitable for a wide range of applications.

The range of sizes available in the 6000 Series allows for versatile installation options. From small diameters suited for laboratory settings to large sizes for industrial processes, Dixon offers flexible solutions to meet customer requirements. This scalability makes the 6000 Series a popular choice among engineers and procurement specialists.

Another notable characteristic of the Dixon 6000 Series is its user-friendly design. The valves are equipped with easy-to-operate handles and mechanisms, facilitating quick adjustments and enhancements in functionality. This ease of use is especially beneficial in fast-paced environments where efficiency is paramount.

Safety is a critical consideration in valve design, and the Dixon 6000 Series does not fall short. The series includes built-in safety features that prevent over-tightening and ensures that the valves remain secure during operation. This attention to safety enhances user confidence and overall operational integrity.

Furthermore, the Dixon 6000 Series is compatible with a variety of systems and can integrate seamlessly with existing piping and fittings. This adaptability is crucial for modernization projects requiring new components to work with older systems.

Overall, the Dixon 6000 Series represents the pinnacle of valve technology. Its combination of durability, innovative design, and safety features makes it an essential choice for industry professionals seeking reliable and efficient solutions for fluid and gas control. Whether in the field or in the factory, the Dixon 6000 Series proves to be a valuable asset in maintaining operational excellence.