Dixon 6000 Series manual Leveling the Deck

Page 33

CARE AND MAINTENANCE

LEVELING THE DECK:

The deck comes from the manufacturer pre-leveled. If the deck does appear to be cutting unlevel follow this procedure.

1. Set all tire pressure to correct specifications (see page 23).

2. Place machine on a level slab of concrete.

3. Move blades by hand so all the blades are pointed in the same direction (see diagram on page 34). Measure from the blade tip (beveled edge) to the ground, all three blades. If there is more than a 3/16" difference from one side to the other, the deck should be leveled.

4. Remove the clevis pin from the rear of the lift spring rod, on the high side. The lift spring rod is two parts-one threaded into the other. Turn the lift spring rod counter- clockwise 2 turns. Reassemble clevis pin and remeasure. Repeat as required to achieve a difference of no more than 3/16" from one side to the other.

5, If the deck is level side to side but high or low at the center blade, both lift spring rods must be adjusted equal amounts. Shortening the lift spring rods will bring the center blade up and lengthening the lift spring rods will let the center blade down.

Lift Spring Rod

Lift Spring

Clevis Pin

Tension Adjust Bolt

Page 33

Image 33
Contents 6000 Important Read Carefully Index Safety Safety Alert Symbol General Operation Do not Slope OperationChildren Service Models6000&7000 Dixon Limited WARRANTYPOLICY- CommercialmodelsSeries Forward Mount SpecificationsSeat Adjustment Instructions Control Locations ControlsParking Brake To GO Backward Blade Drive Circuit BreakerMower Deck CUT Height Lift Lever Towing Operation InstructionsTesting of Safety Interlock Systems Unlock Transmission Starting Instructions Cold EngineEngine has been operated Starting InstructionsGrass Height Suggestions Discharge chuteMaintenance Schedule Care and MaintenanceEngine Belts Mower BladesChecking & Replenishing OIL in Hydrostatic Transmission LubricationParking Brake Adjustment Hydrostatic TransmissionScalper Roller Bolts Hydrostat Drive Belt Tension Adjustment Steering Control Adjustments Steering Control Adjustments Lower and Reattach the Deck see diagram-page Down Hanger Engagedposition Changing the Fluid in Deck Drive Gearbox Checking Deck Drive Gearbox Fluid LevelLeveling the Deck Deck Spindle Belt Diagram Standard Service Parts List Model ZTRKohler AIR and OIL Filter Part Numbers Engine Wont Turn Over TroubleshootingEngine Idles Poorly Page Date OIL Changed Date Engine Tuned Owner InformationSeries 6022

6000 Series specifications

The Dixon 6000 Series is an advanced line of valves designed for a multitude of industrial applications, renowned for its durability, precision, and state-of-the-art technology. Designed to cater to the rigorous demands of various industries, including oil and gas, water management, and manufacturing, the 6000 Series stands out for its reliability and performance.

One of the main features of the Dixon 6000 Series is its robust construction. The valves are made from high-quality materials, including stainless steel and various alloys, ensuring excellent resistance to corrosion and wear. This construction allows the valves to operate in harsh environments, extending their lifespan and reducing maintenance costs.

In terms of technology, the Dixon 6000 Series incorporates advanced sealing mechanisms that provide a tight, leak-proof fit. The valves utilize a combination of O-ring seals and other gasket materials designed to withstand high pressure and temperature fluctuations, making them suitable for a wide range of applications.

The range of sizes available in the 6000 Series allows for versatile installation options. From small diameters suited for laboratory settings to large sizes for industrial processes, Dixon offers flexible solutions to meet customer requirements. This scalability makes the 6000 Series a popular choice among engineers and procurement specialists.

Another notable characteristic of the Dixon 6000 Series is its user-friendly design. The valves are equipped with easy-to-operate handles and mechanisms, facilitating quick adjustments and enhancements in functionality. This ease of use is especially beneficial in fast-paced environments where efficiency is paramount.

Safety is a critical consideration in valve design, and the Dixon 6000 Series does not fall short. The series includes built-in safety features that prevent over-tightening and ensures that the valves remain secure during operation. This attention to safety enhances user confidence and overall operational integrity.

Furthermore, the Dixon 6000 Series is compatible with a variety of systems and can integrate seamlessly with existing piping and fittings. This adaptability is crucial for modernization projects requiring new components to work with older systems.

Overall, the Dixon 6000 Series represents the pinnacle of valve technology. Its combination of durability, innovative design, and safety features makes it an essential choice for industry professionals seeking reliable and efficient solutions for fluid and gas control. Whether in the field or in the factory, the Dixon 6000 Series proves to be a valuable asset in maintaining operational excellence.