INSTALLATION INSTRUCTIONS

IMPORTANT: Read carefully before installing fixture. Retain for future reference.

Epic/Pole Mounted

Fixtures

Sheet 1 of 4

2/18/04 IMI-575

General: Upon receipt of fixture thoroughly inspect for any freight damage, which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct merchandise.

Safety: This fixture must be wired in accordance with the national electrical code and applicable local codes and ordinance. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section. All work should be done by a qualified electrician.

WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.

ARM & FIXTURE INSTALLATION

Bishop Arm (VA6005-VA6008, VA6054-VA6057, VA6105-VA6108

&VA6154-VA6157) See Figure 1.

1.Secure arm onto pole and orient.

Bishop Arm

2. Tighten the six set screws located near bottom of arm to 150 in/lbs. to secure arm.

3. Loosen the three arm cap set screws and remove arm cap.

Arm Cap

Fixture Screws

Teflon Washers

4.Pull fixture leads through arm to arm cap location.

5.Raise fixture to arm aligning locating pin and socket. See Figure 2.

6.Insert and tighten 4 fixture screws with Teflon washers, provided in polybag, to 80 in/lbs.

7.Connect fixture leads to service leads.

8.Resecure arm cap with arm cap set screws tightened to 50 in/lbs.

Traditional Arm (VA6009-VA6021 VA6058-VA6070,

VA6109-VA6121 & VA6158-VA6170)

See Figure 3.

1.Slip arm onto pole and orient.

2.Tighten the six set screws located near bottom of arm to 150 in/lbs. to secure arm.

3.Loosen the three arm cap set screws and remove arm cap.

4.Pull fixture leads through arm to arm cap location.

5.Raise fixture to arm aligning locating pin and socket. See Figure 2.

6.Insert and tighten 4 fixture screws with Teflon washers, provided in polybag, to 80 in/lbs.

7.Connect fixture leads to service leads.

8.Resecure arm cap with arm cap set screws tightened to 50 in/lbs.

Arm Cap

Set Screws

Set Screws

Fig. 1

Modern Top

Aligning Pin

Aligning Socket

Fig. 2a

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-575 AVU040300

Image 1
Contents Sheet 1 ARM & Fixture InstallationBishop Arm Modern TopSheet 2 Fixture MaintenanceFG, FR, SG & FRS Sheet 3 Power Pack Replacement Horizontally lampedOptions 3R & 5R Sheet 4 Power Pack RemovalReflector Removal

IMI-575 specifications

Cooper Lighting's IMI-575 is a highly versatile and efficient lighting solution that stands out in the world of commercial and industrial applications. This fixture is expertly designed to provide powerful illumination while ensuring energy savings and minimal maintenance. The IMI-575 is particularly popular in spaces such as warehouses, gymnasiums, and large retail areas where bright, dependable lighting is crucial.

One of the defining features of the IMI-575 is its exceptional lumen output. Capable of delivering over 57,000 lumens, it ensures vast areas are evenly illuminated, significantly enhancing visibility and safety. The fixture’s high lumen efficacy allows for the application of fewer fixtures in wide spaces, which ultimately reduces installation costs and energy consumption.

A standout technology integrated into the IMI-575 is its LED capability. The use of LED technology not only extends the lifespan of the fixture—offering up to 100,000 hours of operation—but it also dramatically reduces energy consumption by up to 70% compared to traditional lighting solutions. This eco-friendly approach aligns with modern sustainability goals while providing significant cost savings on energy bills.

In addition to its energy efficiency, the IMI-575 features advanced optical designs. The product includes a precision-engineered lens that maximizes light output while controlling glare, ensuring a comfortable lighting experience for users. By minimizing unwanted brightness, the fixture creates an optimal environment that enhances productivity and reduces eye strain.

The IMI-575 is designed for ruggedness and durability, making it ideal for industrial settings. Constructed from high-quality materials, it boasts an IP65 rating which certifies its resistance to dust and water, ensuring reliable performance even in challenging conditions. This durability makes the IMI-575 a favored choice among facility managers looking for a fixture that can withstand the rigors of demanding environments.

Moreover, Cooper Lighting has incorporated smart technology into the IMI-575, allowing for intelligent lighting control. Options for integrating occupancy sensors, daylight harvesting, and dimming provide customization tailored to specific needs while improving energy efficiency further. The fixture can adapt to real-time conditions to minimize unnecessary energy use while maintaining optimal brightness.

In summary, the Cooper Lighting IMI-575 offers a robust blend of high lumen output, energy efficiency, durability, and smart technology. It stands as an excellent choice for those seeking advanced lighting solutions that meet the complexities of modern commercial and industrial spaces.