TECHNICAL SPECIFICATIONS

WEIGHT & DIMENSIONS

 

 

Length

10.2 in (258 mm)

Width

9.5 in (242 mm)

Height

8.9 in (225 mm)

Weight

8.4 lbs (3.8 kg)

POWER

 

 

AC Power

120 V 60 Hz AC or 230 V 50 Hz

Fuse (115V)

8 A 250 V

Power Consumption

774 W (5.9 A) max at 120 V

Inrush Power

(6.5A) at 120 V

Power Factor

0.99 at 120 V

Fuse (230V)

5 A 250

V

Power Consumption

750 W (3.3 A) max at 230

V

Inrush Power

(3.14 A) at 230

V

Power Factor

0.99 at 230

V

THERMAL

 

 

Maximum ambient temperature

104°F (40°C)

CONTROL & PROGRAMMING

 

 

Data input

5-pin & ground DIN5 female socket

Data pin configurationpin1(LED), pin2(control), pin3(+5V), pin4(ground), pin5(none), ground(none)

ORDERING INFORMATION

 

Hurricane™ 1100

F1100

Wired manual remote (included)

FC-M

Wired timer remote (optional)

FC-T

Wireless manual remote (optional)

FC-W

SPARE PARTS ORDERING INFORMATION

Master PCB

P170-F1MSPCB

Heater P120-HT7

 

Pump

P200-F1PUMP

Fluid container

P170-F1FLC

Fluid sensor

P170-F1FLOS

 

Thermal switch

P170-THEF11

Bracket knob

P111-F1BKNOB

Fuse holder

P170-FUSEHOL

 

Manual fog button

P111-F1FOGB

WARRANTY INFORMATION

 

Warranty

1-year limited warranty

Hurricane™ 1100 User Manual

14

Rev. 7

Image 14
Contents Page Table of Contents Unpacking Instructions What Is IncludedBefore YOU Begin Product at a GlanceSafety Instructions Introduction Product OverviewProduct Dimensions 242 mm / 9.5 258 mm / 10.2 225 mm / 8.9 Fuse Replacement SetupAC Power Mounting OrientationManual Remote Operation FC-M Standard Timer Remote Operation FC-T OptionalOperating Instructions Wireless Controller FC-W Optional Mode DipswitchesGeneral Troubleshooting Contact InformationStorage General MaintenanceTechnical Information Return Procedure Technical Specifications Power