Chauvet 56 user manual DMX Primer, Fixture Linking Daisy Chain

Page 15

DMX Primer

The USITT DMX512-A data transmission protocol (DMX, from now on) is based on the EIA-485 standard and it has 512 channels. Any DMX compatible fixture will require one or more consecutive DMX channels to operate. Because of the many different types of DMX compatible fixtures, they may vary in the total number of channels they require.

In addition, there can only be one DMX controller operating on the same DMX connection at any given time. Otherwise, the signals from one controller could interfere with the signals from the other controller, thus causing erratic fixture operation.

Starting Address

Once the user has determined how many channels each fixture requires, he or she must assign the corresponding channels on the DMX controller for it to send the control signals to the intended fixture. In the DMX system, each fixture is identified by its starting address. The starting address is the number of the DMX channel assigned to the first control channel on the fixture.

For instance, a user has two DMX compatible fixtures. One of them has four channels and the other has six channels. The user may configure the starting address of the 4-channel fixture to “001”. This will assign the channels 001 through 004 on the DMX controller to this fixture. To identify the six-channel fixture, the user should assign to it a starting address of “005” or higher. For a starting address of “005”, the DMX controller would use channels 005 to 010 to control the second fixture.

Choosing a starting address should be planned carefully. The first requirement is to avoid channel overlapping. Doing otherwise may result in erratic operation of the affected fixtures. The second requirement is to avoid leaving unassigned channels because this creates unused faders on the DMX controller, which may be critical for small DMX controllers with only a few available faders.

It is possible to control multiple fixtures of the same type by assigning each one of them the same starting address. In this case, all the fixtures would respond in unison (synchronized) to the signals from the DMX controller.

Fixture Linking (Daisy Chain)

DMX compatible fixtures receive the control signals from the DMX controller through the DMX cables. Each fixture has a DMX In and a DMX Out connector. A DMX cable runs from the DMX output of the DMX controller to the DMX input of the first fixture. Another DMX cable runs from the DMX output of the first fixture to the DMX input of the second fixture, and so on. The DMX signals from the controller reach all the fixtures linked with the DMX cable. This type of sequential connection is known as “daisy chain”.

The order in which the fixtures connect to the DMX controller is irrelevant because all fixtures receive the same DMX signals and they only respond to them based on their individual starting addresses. However, you should consider a connection sequence that provides the shortest and most direct cable runs between fixtures.

DMX Controller

1st DMX Fixture

2nd DMX Fixture

To other fixtures

To ensure the integrity of the DMX signal, you should follow the recommendations of the EIA- 485 standard regarding the number of fixtures that can be connected to the DMX daisy chain and the total length of the DMX cable as follows:

The maximum recommended cable length is 500 m (1,640 feet).

The maximum recommended number of fixtures on the same daisy chain is 32.

Connecting more than 32 fixtures on one daisy chain without the use of a DMX optically- isolated splitter may result in deterioration of the digital DMX signal.

SlimPAR™ 56 User Manual (Rev. 04)

Page 15 of 17

Image 15
Contents Page Table of Contents Before YOU Begin Safety Notes Product Overview IntroductionSetup AC PowerPower Linking Mounting OrientationRigging Button Function OperationControl Panel Operation Menu MapAutomatic Mode Configuration DMXConfiguration Standalone Sound Active ModeDo not connect more than 31 slave units to the master unit Static ModeMaster/Slave Mode Custom Static ColorsDMX Channel Assignments and Values CH ModeSetting Channel Function Value SettingTechnical Information General MaintenanceSymptom Possible Cause Possible Action General TroubleshootingReturns Procedure ClaimsContact Information Fixture Linking Daisy Chain DMX PrimerInput DMX CablingTechnical Specifications
Related manuals
Manual 17 pages 47.65 Kb Manual 2 pages 2.9 Kb

56 specifications

Chauvet 56 and 64 are powerful and versatile LED lighting fixtures designed for professional applications in entertainment, events, and architectural settings. Renowned for their robust performance and innovative features, these fixtures have become a staple for lighting designers and technicians.

One of the standout features of the Chauvet 56 and 64 is their impressive LED output. With a high lumen count, these fixtures deliver bright and vibrant colors that can easily cut through ambient light, making them ideal for concerts, theater productions, and large-scale events. The fixture uses multiple high-quality LEDs, which provide excellent color mixing capabilities, allowing users to create a wide range of hues and saturations.

The Chauvet 56 and 64 are equipped with advanced technology like DMX compatibility. This allows users to control the fixtures with precision, integrating them seamlessly into larger lighting setups. With multiple DMX modes available, users can choose from different channel configurations to suit their specific needs, whether for complex programming in live shows or simple operation for events.

Another notable characteristic is their ergonomic design. Both fixtures feature a rugged and durable housing, making them suitable for various environments, whether indoor or outdoor. They are also relatively lightweight, allowing for easy rigging and transportation. This portability is complemented by the fixtures' integrated handles, providing additional convenience for set-up and dismantling.

The onboard control options further enhance their user-friendliness. Chauvet 56 and 64 come with an intuitive control panel, providing easy access to basic functions and settings. Additionally, they support sound activation and pre-programmed shows, making them versatile for a range of applications beyond DMX control.

Energy efficiency is a significant advantage of the Chauvet 56 and 64 fixtures. The LED technology consumes less power than traditional lighting sources, resulting in lower operational costs. This is particularly advantageous for users who need to run their lighting fixtures for extended periods, as it contributes to sustainability and cost-effectiveness.

In conclusion, Chauvet 56 and 64 LED fixtures combine impressive brightness, excellent color mixing, DMX control, and a user-friendly design that caters to both experienced lighting professionals and beginners. Their energy efficiency and durable build make them a reliable choice for diverse lighting applications. Whether for concerts, events, or permanent installations, these fixtures stand out as exemplary products in the world of professional lighting.