Krell Industries KAV2250, KAV 3250 manual Back Panel Description

Page 14

Back Panel Description,

continued

Fuses

10 AGC-12 Fuses

The AGC-12 Amp loudspeaker fuses protect the amplifier against short circuits at the amplifier outputs.

Back Panel Remote Connections

11 12 VDC Remote Power Out

The amplifier is equipped with an output that sends 12 VDC power on/off

(12 V trigger) signals to other Krell components and other devices that incorporate a 12 V trigger.

12 12 VDC Remote Power In

The amplifier is equipped with an input that receives 12 VDC power on/off (12 V trigger) signals from other Krell components and other devices that incorporate a 12 V trigger.

This allows you to turn the amplifier on and off using a Krell or other component in a custom installation.

Notes

When the component is in the operational mode, the 12 VDC Out provides 12 V of DC output. When the component is in the stand-by mode or off, the DC output is 0 V.

12 VDC Out (12 V trigger) current is limited to 30 mA.

Consult the owner’s manual of each component used in a custom installation to take full advantage of the amplifier’s remote capability.

Power

13 IEC Power Connector

The amplifier is equipped with a standard female IEC power connector, for use with the provided AC power cord.

14 Back Panel Power Switch

Use this switch to turn the amplifier from off to the stand-by mode.

10

Krell KAV–2250 and KAV–3250

Image 14
Contents Instructions for Use Owner’s Reference Stereo Power AmplifierThree-channel Power Amplifier KAV-2250 Stereo Power Amplifier Contents Illustrations KAV-2250 Front PanelIntroduction Input and Output Connections ConfigurationsDefinition of Terms Definition of Terms OperationTechnology Unpacking Specifications PlacementAC Power Guidelines Power CordKAV-2250 Front Panel Front Panel Description Power ButtonPower Indicator Stand-by LEDKAV-2250 Back Panel Inputs Reconfiguration Options for the KAV-2250 and the KAV-3250Back Panel Description OutputsBack Panel Description Connecting the Amplifier to Your System Connecting the Amplifier ON/OFF and Operation Using a Dedicated Wall SwitchAmplifier Operation Off firstTroubleshooting System Noise Reconfiguration Options for the KAV-2250 and KAV-3250 To Safely Access the Input Switch BanksAmplifier Factory Default Settings Reconfiguring the KAV-2250 for MAT Operation Reconfiguration Options Amplifier Factory Default SettingsReconfiguring the Amplifier for MAT Operation Not illustrated Reconfiguring the KAV-2250 for Bridged Operation Reconfiguring the Amplifier for Bridged Operation Connecting the Amplifier Reconfigured for MATLoudsp Questions and Answers Connecting the Amplifier to Your SystemWarranty If you have purchased your Krell product outside the U.S.AReturn Authorization Procedure To contact the Krell Service DepartmentSpecifications KAV-2250KAV-3250 KAV-2250