American Standard 2709.XXXW Electrical Diagram Read and Follow ALL Instructions

Page 3

ELECTRICAL INSTALLATION INSTRUCTIONS

All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.

WARNING:

When using electrical products, basic precautions should always be observed, including the following:

1.DANGER: RISK OF ELECTRIC SHOCK

Connect only to a circuit protected by a ground-fault circuit interrupter.

2.Grounding is required. The unit should be installed by a licensed electrician and grounded.

3.Install to permit access for servicing.

4.All building materials and wiring should be routed away from the pump body and heater (if equipped).

2.1 HORSEPOWER MODELS:

The whirlpool should be installed on a 120 vac, 20 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit fron the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT.

ELECTRICAL INSTALLATION

 

SEPARATE 20 AMP GFCI

 

120 VAC

 

WHIRLPOOL MOUNTED

 

AIR or ELECTRONIC SWITCH

 

or

 

WALL TIMER-

WHITE

(2.1HP AIRSWITCH MODELS ONLY)

BLACK

 

PUMP/MOTOR

 

GND.

ELECTRICAL DIAGRAM

READ AND FOLLOW ALL INSTRUCTIONS

751753-100 Rev. J

(3)

Image 3
Contents General Specifications for 2709 Whirlpool General Installation InformationFraming and Installation Suggested Installation Method Typical InstallationElectrical Diagram Read and Follow ALL Instructions Harsh Chemicals should Never be Used on Acrylic Surfaces Wire Selection GuidePost Installation CLEAN-UP Drain Connection and System Test