Plug power cord into a grounded electrical outlet. If necessary, turn power switch on rear of unit to “ON” position.

To extrude liquid, press the appropriate button on the remote for the desired length of time.

For further information on operating your ANTARI Liquid Control Unit, refer to the Antari onboard, “Remote Control Operation”.

For details regarding DMX, refer to the Antari onboard DMX fog machine settings section.

If you experience low output, pump noise or no output at all, unplug immediately. Check Tank fluid level, the external fuse, remote connection, and power from the wall. If all of the above appears to be O.K., plug the unit in again. If fluid does not come out after holding the remote button down for 30 seconds, check the tube attached to the tank to make sure there is fluid going through the tube. If you are unable to determine the cause of the problem, do not simply continue pushing the remote button, as this may damage the unit. Return the machine to your ANTARI dealer.

Cleaning your fog machine regularly will help reduce costly parts

replacement and repair charges.

Maintenance

Do not allow the fog liquid to become contaminated. Always replace the caps on the fog liquid container and the fog machine liquid tank immediately after filling.

After every 40 hours of continuous operation, it is recommended to run a cleaning solution composed of 80% distilled water/20% white vinegar