Cal Spas LTR20111002 manual Inground Spa Light Installation In- structions, See figure below

Page 21

Inground Spa Light Installation In- structions

On spas ordered with inground lights, the factory installs the light niche for you. The next steps of installation should be performed by a qualified licensed electrician.

Always read and follow light manufacturer’s safety and installation instructions prior to installation and operation. Incorrect installation may damage the light and void its warranty.

The light circuit must be on a GFCI protected service (alone or with a switch).

The water resistant junction box (or for 12 volt models, the low voltage transformer) must be located:

at least 8” (20 cm) above water level

at least 4” (10 cm) above ground level, and

at least 48” (121 cm) away from the spa..

See figure below.

Light niche and any metallic items in a 5’ (152 cm) radius must be properly bonded with #8 AWG grounding wire.

1.Connect rigid conduit to the 3/4” hub located at the back of the light niche and run to a water re- sistant junction box (or for 12 volt models to a low voltage transformer) no further than 25’ (7.6m).

Remember this is a water cooled light, so the con- duit and all connections must be leakproof.

Inground Spas

2.Feed the light cord through the rigid conduit to the junction box, leaving at least 4 feet of cord at the end of the light fixture. This slack in the light cord will allow servicing without draining the spa in the future.

3.Wrap light cord slack around back of light housing and attach light to niche with mounting screw.

4.Cut the cord at the junction box, leaving at least

6” (15 cm) of cord to make connections.

5.Strip 6” (15 cm) of the out cord jacket to expose the three insulated wires. Be careful not to dam- age the insulation on the three inner wires.

6.Connect the three wires to the corresponding cir- cuit wires in the junction box and secure the junc- tion box cover in place.

7.Replace the light assembly in the niche and tight- en the special pilot screw.

8.Fill the spa until the underwater light is completely submerged in water before operating the light for more than 10 seconds. Turn on the main switch or circuit breaker, as well as the spa light control, to check for proper operation

Important: Make sure spa light is submerged in at least 18” of water prior to testing..

21 Preparingfor

Your New Inground Spa

LTR20111002, Rev. A

www.calspas.com

Image 21
Contents LTR20111002, Rev. a 1/24/11 Cleaning and Maintenance Preparing for Your New Inground Spa Clear Water PlanElectronic Control Operation Appendix Important Safety Instructions Read This FirstHyperthermia Danger Preparing for Your New Inground Spa Inground Spa Installation ChecklistInground Spa ForYour NewPreparing forYour New Planning the Best Place for the Outdoor Equipment PackInground Spa Site Preparation SpaSpa Shell Dimensions and Side Views Preparing forYour New Inground SpaIG-401 IG-402 Your New Inground SpaIG-403 IG-404 IG-405 IG-406 IG-407 Testing the Gfci Breaker Gfci and Wiring RequirementsSpa Model Gfci Required Wires Required Electrical Requirements US and CanadaGfci Wiring Diagram Electrical Installation -- Europe RCD and Wiring RequirementsTesting the RCD Breaker RCD Wiring Diagram NewYour SpaIngroundForPreparing Installing the Inground Shell Plumbing Connections Equipment Pack Plumbing ConnectionsGate/Slice Valves Connecting Plumbing to Remote EquipmentElectrical and Electronic Connection Preparing forYour New IngroundRemote Equipment Topside Control Panel See figure below Inground Spa Light Installation In- structionsPreparing forYour New Inground Spa Pouring the Deck Your Spa Electronic Control OperationPreset Filter Cycles Setting the Temperature LockClean-up Cycle LightOperating SpaYour Message Meaning Action Required No message Diagnostic MessagesOn display DryMessage Meaning Action Required Snb SnsStby Diverter Knobs Adjustable JetsClear Water Plan Contents of this sectionClear PlanWater Key to Clear WaterClear Water Plan Testing and Adjusting Spa WaterBalancing the Total Alkalinity Balancing the pHUsing Chlorine as a Sanitizer Using Bromine as a SanitizerSanitation Shocking the Water Chemical SafetyBather Load Filter CleaningWater Plan Starting the Spa with Fresh WaterMaintenance Schedule Problem Probable Causes Possible Solutions Troubleshooting Water Clarity ProblemsCleaning and Maintenance Removing and Reseating the PillowsSpa Cover Cleaning and Replacing the Filter Draining Your SpaWinterizing Cold Climate Draining Cleaning Cleaning the Cover, Shell and PillowsFast Sheen Spa finish protecting wax Replacement Parts WarrantyAppendix Cal Spas Chemicals LTR20111002, Rev. a 1/24/11