Dolmar PB-250.4 Operation, Starting, When the engine is cold, or when the fuel it refueled

Page 11

OPERATION

1. Starting

WARNING

Never attempt engine start in a place where the fuel has been supplied. When starting the engine, keep a distance of at least 3 m.

-Otherwise, it will may cause ignition or fire.

Exhaust gas from the engine has toxic consequences. Do not operate the engine in a poorly-ventilated place, such as in a tunnel, building, etc.

-Operating the engine in the poorly-ventilated place may cause poisoning by exhaust gas.

In case of detection of any abnormality in sound, odor, vibration after start, stop the engine immediately and carry out inspection.

-If the engine is operated without attending such abnormality, an accident may occur.

Confirm that the engine stops when the stop switch is set to “O” position.

1)When the engine is cold, or when the fuel it refueled

(1)Set this machine on a flat space.

(2)Set the stop switch to “ I “ position.

(3)Continue to push the primer pump until fuel enters into the

primer pump.

In general, fuel enters into the carburetor by 7 to 10 pushes.

If the primer pump is pushed excessively, an excess of gasoline returns to the fuel tank.

(4)Lifting the choke lever of the air cleaner right side, close the choke lever.

(5)Hold the main handle with a left hand to prevent the engine from moving, settle down to take the stable position.

(6)Pull out slowly the starter handle till a certain resistance is felt.

Return the starter handle backward once from this position, then pull it out with force.

Never pull the rope to the full.

Once the start knob is pulled, never release your hand

immediately. Hold the start knob until it returns to its original point.

(7) When the engine starts, open the choke lever.

Open the choke lever progressively while checking the engine operation. Be sure to open the choke lever to the full in the end.

In cold or when the engine is cooled down, never open the

choke lever suddenly. Otherwise, the engine may stop.

(8)Continue warm-up operation for 2 to 3 minutes.

(9)Rotation of the engine speed stabilizes and when from low speed making at high speed rotation, if reaches the point where it accelerates smoothly, it is completion of warming-up.

(2)

Stop Switch

(3)

Primer pump

(4)

Close

 

 

 

 

 

 

 

 

 

(6)

(7)

Open

11

Image 11
Contents Importante PB-250.4English Table of Contents15meters Safety InstructionsMeters Resting Transport Refuelling Maintenance Tool ReplacementMethod of operation NGK CMR6A SpecificationDesignation of Parts Always wear protective gloves Assembly InstructionsInspection and Refill of Engine Oil Point 1 in Replacement of Oil Oil GaugePoint 2 in Replacement of Oil If oil spills out Before Start of OperationPoints for Fuel Storage of machine and refill tankStarting When the engine is cold, or when the fuel it refueledOperation Checkup of low-speed rotation Adjustment of IdlingStopping Dust Collection Operation Operation MethodBlower operation Points in replacement of engine oil Inspection and MaintenanceReplacement of engine oil Checking the spark plug Cleaning of air cleanerStorage Cleaning the fuel filterCleaning of parts Replacement of gaskets and packingsFault location State of abnormality Probable cause malfunction Remedy TroubleshootingEmission Compliance Period Owners Warranty Responsibilities Manufacturers Warranty CoverageWaranty Commencement Date What is CoveredWhat is not Covered HOW to File a ClaimMaintenance Statements Where to GET Warranty ServiceParts Covered Under the California Emission Warranty Repair and Replacement of EMISSION-RELATED Parts Obtaining Warranty Service HOW to Make a Claim