Efficient Networks S120 manual Examples when changing sampling times / pulse frequencies, Mixed

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 529
Image 529

Basic information about the drive system 12.12 System sampling times

Construction type

Number

 

p0112

 

p0115[0]

p1800

Booksize

1 to 2 only n_ctrl

3

(Standard)

250

µs

4 kHz

 

1 to 4 only V/f

 

 

 

 

 

Chassis

 

 

 

 

2 kHz

1 to 2 n_ctrl and

 

 

 

 

400 V / ≤ 250 kW

 

 

 

 

 

V/f mixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Booksize

3 to 4 only n_ctrl

0

(Expert)

500

µs

4 kHz

Chassis

5 to 6 only V/f

 

 

 

 

2 kHz

3 to 4 n_ctrl and

 

 

 

 

400 V / ≤ 250 kW

 

 

 

 

 

V/f mixed

 

 

 

 

 

 

 

 

 

 

 

Chassis

1 to 3 only n_ctrl

0

(Expert)

375

µs (p0092 = 1)

1.333 kHz

> 250 kW

1 to 6 only V/f

1

(xLow)

400

µs (p0092 = 0)

1.25 kHz

690 V

1 to 3 n_ctrl and

 

 

 

 

 

 

V/f mixed

 

 

 

 

 

 

4 only n_ctrl

0

(Expert)

500

µs (p0092 = 1)

2 kHz

 

4 n_ctrl and V/f

1

(xlow)

400

µs (p0092 = 0)

1.25 kHz

 

mixed

 

 

 

 

 

Booksize

> 6 only V/f

0 (Expert)

500 µs

4 kHz

Chassis

 

 

 

 

 

2 kHz

Blocksize

1 to 2 only n_ctrl

3

(Standard)

250

µs

4 kHz

 

1 to 4 only V/f

 

 

 

 

 

 

> 2 n_ctrl (min. 1)

0

(Expert)

500

µs

4 kHz

 

> 4 only V/f

 

 

 

 

 

Caution

 

 

 

 

 

 

If a Power Module Blocksize is connected to a Control Unit, the sampling times of all vector drives are set according to the rules for Power Modules Blocksize (only 250 µs or 500 µs possible).

12.12.5Examples when changing sampling times / pulse frequencies

Example: Changing the current controller sampling time from 62.5 µs with p0112

Preconditions:

Maximum 2 drives, Booksize format

Servo motor control type

Procedure:

1.p0009 = 3 (not for offline operation)

2.Switch to the first servo drive object

3.p0112 = 4

4.Switch to the second servo drive object and repeat step 3.

5.p0009 = 0 (not for offline operation)

6.When STARTER is in offline mode: Download into the drive.

Drive Functions

529

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 529
Image 529
Efficient Networks S120 manual Examples when changing sampling times / pulse frequencies, Number P0112 P01150 P1800, Mixed