Basic information about the drive system 12.10 Rules for wiring with DRIVE-CLiQ

Comparison of topologies at Power On

Comparing the topologies prevents a component from being controlled/evaluated incorrectly (e.g. drive 1 and 2).

When the drive system is started, the Control Unit compares the detected actual topology and the electronic type plates with the target topology stored on the CompactFlash card.

You can specify how the electronic type plates are compared for all the components of a Control Unit via p9906. The type of comparison can be changed subsequently for each individual component. You can use p9908 for this or right-click in the topology view in the STARTER tool. All data on the electronic type plate is compared by default.

The following data in the target and actual topologies is compared depending on the settings made in p9906/9908:

p9906/9908 = 0: component type, order number, manufacturer, serial number

p9906/9908 = 1: component type, order number

p9906/9908 = 2: component type

p9906/9908 = 3: component class (e.g. Sensor Module or Motor Module)

Figure 12-21 Topology view in the STARTER tool

NOTICE

The Control Unit and the Option Board are not monitored. The system automatically accepts new components and does not output a message.

12.10Rules for wiring with DRIVE-CLiQ

The following rules apply for wiring components with DRIVE-CLiQ. The rules are subdivided into DRIVE-CLiQ rules, which must be observed, and recommended rules, which, when observed, do not require any subsequent changes to the topology created offline in

STARTER.

The maximum number of DRIVE-CLiQ components and the possible wiring form depend on the following points:

The binding DRIVE-CLiQ wiring rules

The number and type of activated drives and functions on the Control Unit in question

The computing power of the Control Unit in question

Drive Functions

505

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 505
Image 505
Efficient Networks S120 manual Rules for wiring with DRIVE-CLiQ, Comparison of topologies at Power On