Efficient Networks S120 manual Basic information about the drive system 12.13 Licensing

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 531
Image 531

Basic information about the drive system 12.13 Licensing

r0111 DRIVE-CLiQ basis sampling time selection

p0112 Sampling times pre-setting p0115

p0113 Selects the minimum pulse frequency

r0114 Recommended minimum pulse frequency

p0115[0..6] Sampling times for internal control loops

r0116 Recommended drive sampling time

p0118 Current controller computation deadtime

p0799 CU inputs/outputs sampling time

p1800 Pulse frequency

p4099 Inputs/outputs sampling time

r9780 SI monitoring clock cycle (Control Unit)

r9880 SI monitoring clock cycle (Motor Module)

12.13Licensing

Description

To use the SINAMICS S120 drive system and the activated options, you need to assign the corresponding licenses to the hardware. When doing so, you receive a license key, which electronically links the relevant option with the hardware.

The license key is an electronic license stamp that indicates that one or more software licenses are owned.

Actual customer verification of the license for the software that is subject to license is called a certificate of license.

Note

Refer to the order documentation (e.g. catalogs) for information on basic functions and functions subject to license.

An insufficient license is indicated via the following alarm and LED on the Control Unit:

A13000 License not sufficient

READY LED Flashes green/red at 0.5 Hz

NOTICE

The drive can only be operated with an insufficient license during commissioning and servicing.

The drive requires a sufficient license in order for it to operate normally.

Drive Functions

531

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 531
Image 531
Efficient Networks S120 manual Basic information about the drive system 12.13 Licensing