Basic information about the drive system 12.4 BICO technology: interconnecting signals

Fixed values for interconnection using BICO technology

The following connector outputs are available for interconnecting any fixed value settings:

p2900[0...n] CO: Fixed value_%_1

p2901[0...n] CO: Fixed value_%_2

p2930[0...n] CO: Fixed value_M_1 Example:

These parameters can be used to interconnect the scaling factor for the main setpoint or to interconnect an additional torque.

12.4.7Scaling

Signals for the analog outputs

Table 12-5 List of signals for analog outputs

Signal

Parameter

Unit

Normalization

 

 

 

(100 % = ...)

Speed setpoint before the setpoint

r0060

RPM

p2000

filter

 

 

 

Speed actual value motor encoder

r0061

RPM

p2000

Actual speed

r0063

RPM

p2000

Drive output frequency

r0066

Hz

Reference frequency

Absolute current actual value

r0068

Aeff

p2002

Actual DC link voltage value

r0070

V

p2001

Total torque setpoint

r0079

Nm

p2003

Actual active power

r0082

kW

r2004

Control deviation

r0064

RPM

p2000

Modulation depth

r0074

%

Reference control factor

Current setpoint, torque-generating

r0077

A

p2002

Current actual value, torque-

r0078

A

p2002

generating

 

 

 

Flux setpoint

r0083

%

Reference flux

Flux actual value

r0084

%

Reference flux

Speed controller

r1480

Nm

p2003

PI torque output

 

 

 

Speed controller

r1482

Nm

p2003

I torque output

 

 

 

Drive Functions

483

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4