Efficient Networks S120 manual Control Units without infeed control

Models: S120

1 560
Download 560 pages 21.93 Kb
Page 463
Image 463

Applications 11.5 Control Units without infeed control

11.4.6Overview of key parameters (see SINAMICS S List Manual)

p0105 Activate/deactivate drive object

r0106 Drive object active/inactive

p0897 BI: Parking axis selection

r0896.0 BO: Parking axis status word

p0151 DRIVE-CLiQ Hub component number

p0154 DRIVE-CLiQ Hub identification using LED

p0157 DRIVE-CLiQ Hub EPROM data version

r0158 DRIVE-CLiQ Hub firmware version

11.5Control Units without infeed control

11.5.1Description

Description

To ensure that the drive line-up functions satisfactorily, you must ensure – among other things – that the drives only draw power from the DC link when the infeed is in operation. In a DC link line-up that is controlled by just one Control Unit and in which a drive object has an infeed, the BICO interconnection p0864 = p0863.0 is established automatically during commissioning.

In the following cases, the BICO input p0864 must be supplied manually:

Smart Line Modules without DRIVE-CLiQ (5 kW and 10 kW)

DC link line-up with more than one Control Unit

Drive Functions

463

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 463
Image 463
Efficient Networks S120 manual Control Units without infeed control, Overview of key parameters see Sinamics S List Manual