Basic functions

 

 

 

6.7 Automatic restart (vector, servo, infeed)

Automatic restart mode

 

 

 

Table 6-6

Automatic restart mode

 

 

 

 

 

 

p1210

Mode

Meaning

 

0

Disables automatic restart

Automatic restart inactive

 

1

Acknowledges all faults without

When p1210 = 1, faults that are present are

 

 

restarting

acknowledged automatically when their cause is

 

 

 

rectified. If further faults occur after faults have been

 

 

 

acknowledged, then these are also again

 

 

 

automatically acknowledged. A minimum time of

 

 

 

p1212 + 1s must expire between successful fault

 

 

 

acknowledgement and a fault re-occurring if the

 

 

 

signal ON/OFF1 (control word 1, bit 0) is at a HIGH

 

 

 

signal level. If the ON/OFF1 signal is at a LOW

 

 

 

signal level, the time between a successful fault

 

 

 

acknowledgement and a new fault must be at least

 

 

 

1s.

 

 

 

For p1210 = 1, fault F07320 is not generated if the

 

 

 

acknowledge attempt failed (e.g. because the faults

 

 

 

occurred too frequently).

 

4

Automatic restart after line

For p1210 = 4, an automatic restart is only carried

 

 

supply failure, no additional start

out if in addition fault F30003 occurred at the Motor

 

 

attempts

Module or there is a high signal at binector input

 

 

 

p1208[1], or in the case of an infeed drive object

 

 

 

(x_Infeed) F06200 has occurred. If additional faults

 

 

 

are present, then these faults are also

 

 

 

acknowledged and when successfully

 

 

 

acknowledged, the starting attempt is continued.

 

 

 

When the 24 V power supply of the CU fails, this is

 

 

 

interrupted as a line supply failure.

 

6

Restart after any fault with

When p1210 = 6, an automatic restart is carried out

 

 

additional start attempts

after any fault or when p1208[0] = 1. If the faults

 

 

 

occur one after the other, then the number of start

 

 

 

attempts is defined using p1211. Monitoring over

 

 

 

time can be set using p1213.

Starting attempts (p1211) and waiting time (p1212)

p1211 is used to specify the number of starting attempts. The number is internally decremented after each successful fault acknowledgement (line supply voltage must be re- applied or the infeed signals that it is ready. Fault F07320 is signaled if the number of parameterized startup attempts is exceeded.

When p1211 = x, x + 1 starting attempts are made.

Note

A start attempt immediately starts when the fault occurs.

The faults are automatically acknowledged in intervals of half the waiting time p1212.

After successfully acknowledgment and the voltage returns, then the system is automatically powered-up again.

Drive Functions

189

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Page 189
Image 189
Efficient Networks S120 manual Starting attempts p1211 and waiting time p1212, Automatic restart mode, P1210 Mode Meaning